Event Notification Report for May 10, 2022

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/09/2022 - 05/10/2022

EVENT NUMBERS
558915589255893
Power Reactor
Event Number: 55891
Facility: Quad Cities
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: Harlem - Eq Opr
HQ OPS Officer: Brian P. Smith
Notification Date: 05/10/2022
Notification Time: 23:42 [ET]
Event Date: 05/10/2022
Event Time: 13:59 [CDT]
Last Update Date: 05/11/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(B) - Pot Rhr Inop
Person (Organization):
Skokowski, Richard (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
EN Revision Imported Date: 5/12/2022

EN Revision Text: BOTH TRAINS OF LOW PRESSURE COOLANT INJECTION (LPCI) INOP

The following information was provided by the licensee via fax:

"At 1359 CDT on May 10, 2022, the 1B LPCI Loop Upstream Injection valve (1-1001-28B) was found to have a motor operated torque switch issue and inadequate lubrication. This issue called into question the ability of the valve to close when required.

"At 1746 CDT on May 10, 2022, both trains of Unit 1 LPCI were made simultaneously inoperable. TS 3.6.1.3 Condition A required de-activation of 1B LPCI Loop Downstream Injection valve (1-1001-29B) which was completed at 1746 CDT. Because of the de-activation of the 1B LPCI Loop downstream injection valve and LPCI Loop select logic, both trains of LPCI were made inoperable. Due to this inoperability, the system was in a condition that could have prevented the fulfillment of a safety function; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(V). Unit 1 HPCI and both loops of Core Spray are operable. After further engineering review, it was determined that 1B LPCI Loop Upstream injection valve condition was minor in nature and would not have affected the ability of the valve to close when required.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."

* * * UPDATE AT 12:32 EDT ON 05/11/22 FROM MARK HUMPHREY TO BRIAN P. SMITH * * *

The following information was provided by the licensee via phone call and email:

The last sentence in the second paragraph, "After further engineering review, it was determined that 1B LPCI Loop Upstream injection valve condition was minor in nature and would not have affected the ability of the valve to close when required," has been deleted. The licensee is continuing to follow up on the issue and believes that sentence to be unclear and premature.

Notified R3DO (Skokowski).


Agreement State
Event Number: 55892
Rep Org: California Radiation Control Prgm
Licensee: City of Hope
Region: 4
City: Duarte   State: CA
County:
License #: 0307-19
Agreement: Y
Docket:
NRC Notified By: Robert Greger
HQ OPS Officer: Donald Norwood
Notification Date: 05/10/2022
Notification Time: 23:57 [ET]
Event Date: 05/10/2022
Event Time: 00:00 [PDT]
Last Update Date: 05/11/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Gaddy, Vincent (R4DO)
Event Text
AGREEMENT STATE REPORT - UNDERDOSE MEDICAL EVENT

The following information was received via e-mail:

"The City of Hope Radiation Safety Officer contacted LA County Radiation Management (LA County) on May 10, 2022 to report a Medical Event that occurred on the same day at City of Hope in Duarte, CA. The patient was underdosed during a Selective Internal Radiation Therapy (SIRT) treatment for liver cancer that involved the administration of SIR-Spheres yttrium-90 (Y-90) resin microspheres. The prescribed dose to the patient was 10 mCi, but the dose delivered to the patient was only 6.42 mCi due to a leakage caused by a loose tubing connection.

"City of Hope will conduct an investigation to gain a better understanding of the details of the event."

California 5010 Number: 051022

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.



Power Reactor
Event Number: 55893
Facility: Millstone
Region: 1     State: CT
Unit: [3] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Joshua Keith
HQ OPS Officer: Brian P. Smith
Notification Date: 05/11/2022
Notification Time: 18:12 [ET]
Event Date: 05/10/2022
Event Time: 21:21 [EDT]
Last Update Date: 05/11/2022
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Ferdas, Marc (R1DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
FITNESS FOR DUTY REPORT

The following information was provided by the licensee via email:

"A licensed operator had a confirmed positive for alcohol during a follow-up fitness-for-duty test. The employee's access to the plant is on hold in accordance with the licensee's fitness-for-duty policy.

"The licensee notified the NRC Resident Inspector."