Event Notification Report for April 07, 2022
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/06/2022 - 04/07/2022
Agreement State
Event Number: 55809
Rep Org: Iowa Department of Public Health
Licensee: Equistar Chemicals, LP
Region: 3
City: Clinton State: IA
County:
License #: 0101123FG
Agreement: Y
Docket:
NRC Notified By: Derek Elling
HQ OPS Officer: Lloyd Desotell
Licensee: Equistar Chemicals, LP
Region: 3
City: Clinton State: IA
County:
License #: 0101123FG
Agreement: Y
Docket:
NRC Notified By: Derek Elling
HQ OPS Officer: Lloyd Desotell
Notification Date: 03/30/2022
Notification Time: 15:22 [ET]
Event Date: 03/29/2022
Event Time: 00:00 [CDT]
Last Update Date: 03/30/2022
Notification Time: 15:22 [ET]
Event Date: 03/29/2022
Event Time: 00:00 [CDT]
Last Update Date: 03/30/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Kozak, Laura (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Kozak, Laura (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 4/7/2022
EN Revision Text: AGREEMENT STATE REPORT - STUCK OPEN SHUTTER
The following information was obtained from the state of Iowa via e-mail:
"When conducting routine shutter checks on an Ohmart/Vega SHLG-2 fixed gauge, the operator was not able to extend the plunger to move the source into a shielded position (use of hands and basic tools). The device is in a facility that is restricted access and unmanned due to chemical production. Unless manually operated for shutter checks or vessel maintenance, the standard position of this device is open. No increase of radiation levels compared to standard operating conditions. Radiation Safety Officer has contacted Vega for corrective action guidance and direct support. Initial guidance is the application of a coil lubricant and rotating the handle. Any action above this will be performed by a Vega service technician. The Licensee has a scheduled shutdown of the production line next week when they will schedule the Vega tech for support."
"Source/Radioactive Material: SEALED SOURCE GAUGE
Manufacturer: OHMART CORP.
Model Number: A-2102 IAEA Category: 3
Serial Number: 9849CN
Radionuclide: Cs-137
Activity: 4 Ci (148 GBq)
Iowa Event Number: IA220002"
EN Revision Text: AGREEMENT STATE REPORT - STUCK OPEN SHUTTER
The following information was obtained from the state of Iowa via e-mail:
"When conducting routine shutter checks on an Ohmart/Vega SHLG-2 fixed gauge, the operator was not able to extend the plunger to move the source into a shielded position (use of hands and basic tools). The device is in a facility that is restricted access and unmanned due to chemical production. Unless manually operated for shutter checks or vessel maintenance, the standard position of this device is open. No increase of radiation levels compared to standard operating conditions. Radiation Safety Officer has contacted Vega for corrective action guidance and direct support. Initial guidance is the application of a coil lubricant and rotating the handle. Any action above this will be performed by a Vega service technician. The Licensee has a scheduled shutdown of the production line next week when they will schedule the Vega tech for support."
"Source/Radioactive Material: SEALED SOURCE GAUGE
Manufacturer: OHMART CORP.
Model Number: A-2102 IAEA Category: 3
Serial Number: 9849CN
Radionuclide: Cs-137
Activity: 4 Ci (148 GBq)
Iowa Event Number: IA220002"
Agreement State
Event Number: 55810
Rep Org: SC Dept of Health & Env Control
Licensee: DAK Americas LLC
Region: 1
City: Gaston State: SC
County:
License #: 189
Agreement: Y
Docket:
NRC Notified By: Leland R. Cave
HQ OPS Officer: Lloyd Desotell
Licensee: DAK Americas LLC
Region: 1
City: Gaston State: SC
County:
License #: 189
Agreement: Y
Docket:
NRC Notified By: Leland R. Cave
HQ OPS Officer: Lloyd Desotell
Notification Date: 03/30/2022
Notification Time: 15:24 [ET]
Event Date: 03/29/2022
Event Time: 00:00 [EDT]
Last Update Date: 03/30/2022
Notification Time: 15:24 [ET]
Event Date: 03/29/2022
Event Time: 00:00 [EDT]
Last Update Date: 03/30/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Werkheiser, Dave (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Werkheiser, Dave (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 4/7/2022
EN Revision Text: AGREEMENT STATE REPORT - FIXED GAUGE STUCK SHUTTER
The following is a summary of information provided by the South Carolina Department of Health and Environmental Control (the Department) via email and phone:
On 3/4/2022, the Department was notified by the licensee's Radiation Safety Officer that while an engineer was attempting to retract the source from a fixed gauge, the gauge became locked with the source in an unshielded position. The source was subsequently retracted to a shielded position. The source is a 70 milliCi Cs-137 source (serial number 6280CO) contained in a VEGA SHLM-CR-2 housing. The manufacturer is expected to come to the plant on March 31, 2022 to evaluate the gauge and make any necessary repairs.
No overexposures occurred as a result of this event.
EN Revision Text: AGREEMENT STATE REPORT - FIXED GAUGE STUCK SHUTTER
The following is a summary of information provided by the South Carolina Department of Health and Environmental Control (the Department) via email and phone:
On 3/4/2022, the Department was notified by the licensee's Radiation Safety Officer that while an engineer was attempting to retract the source from a fixed gauge, the gauge became locked with the source in an unshielded position. The source was subsequently retracted to a shielded position. The source is a 70 milliCi Cs-137 source (serial number 6280CO) contained in a VEGA SHLM-CR-2 housing. The manufacturer is expected to come to the plant on March 31, 2022 to evaluate the gauge and make any necessary repairs.
No overexposures occurred as a result of this event.
Agreement State
Event Number: 55811
Rep Org: OK Deq Rad Management
Licensee: Goodyear Tire and Rubber Co.
Region: 4
City: State: OK
County:
License #: GLD0013
Agreement: Y
Docket:
NRC Notified By: Kevin Sampon
HQ OPS Officer: Brian Lin
Licensee: Goodyear Tire and Rubber Co.
Region: 4
City: State: OK
County:
License #: GLD0013
Agreement: Y
Docket:
NRC Notified By: Kevin Sampon
HQ OPS Officer: Brian Lin
Notification Date: 03/31/2022
Notification Time: 11:17 [ET]
Event Date: 03/01/2022
Event Time: 00:00 [CDT]
Last Update Date: 03/31/2022
Notification Time: 11:17 [ET]
Event Date: 03/01/2022
Event Time: 00:00 [CDT]
Last Update Date: 03/31/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: AGREEMENT STATE REPORT - LOST STATIC METER
The following information was received from the State of Oklahoma via email:
"Goodyear Tire and Rubber Co. has reported the loss of a 3M Model 703 Static Meter (S/N 411617). This device was possessed under Oklahoma GLD [generally licensed device] registration GLD0013. It was manufactured in 1977 and initially contained 250 mCi of tritium, which would have decayed to approximately 20 mCi today. Goodyear obtained the device in 2002 and used it for 2 or 3 years before placing it into storage. It was discovered missing earlier this month."
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST STATIC METER
The following information was received from the State of Oklahoma via email:
"Goodyear Tire and Rubber Co. has reported the loss of a 3M Model 703 Static Meter (S/N 411617). This device was possessed under Oklahoma GLD [generally licensed device] registration GLD0013. It was manufactured in 1977 and initially contained 250 mCi of tritium, which would have decayed to approximately 20 mCi today. Goodyear obtained the device in 2002 and used it for 2 or 3 years before placing it into storage. It was discovered missing earlier this month."
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55812
Rep Org: Oregon Health Authority
Licensee: Salem Hospital
Region: 4
City: Salem State: OR
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Daryl A. Leon
HQ OPS Officer: Karen Cotton-Gross
Licensee: Salem Hospital
Region: 4
City: Salem State: OR
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Daryl A. Leon
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 03/31/2022
Notification Time: 12:56 [ET]
Event Date: 03/22/2022
Event Time: 00:00 [PDT]
Last Update Date: 03/31/2022
Notification Time: 12:56 [ET]
Event Date: 03/22/2022
Event Time: 00:00 [PDT]
Last Update Date: 03/31/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: AGREEMENT STATE REPORT - LOST/RECOVERED SOURCE
The following information was provided by the Oregon Health Authority via email:
"On March 22, 2022, a High Dose Rate Delivery (HDR) sealed source of Iridium-192 was delivered by a common carrier to the wrong floor and clinic in a licensed (Salem Hospital) hospital. Instead of the shipping destination (given as Radiation Oncology/Attn: Dr xxx) on the 1st floor, the package was delivered to the 4th floor of the same building. The person receiving the package, who does not have radiation safety or transportation training, signed for it without an understanding of what it was and placed it on the floor of an access-controlled staff working area.
"On March 28, 2022, the licensee received an email request from the vendor (Varian) to schedule a date/time for installation of the new source. It was at this time that the licensee realized that the source had not arrived at their location and found the source had been delivered on March 22, 2022. An investigation was initiated and the source package was located in the 4th floor clinic. The package was surveyed and observed to be intact with no evidence of tampering . The transport index for the Type A Yellow -II package was noted at 0.9. The package was taken to the licensee's office and secured in locked storage.
"The licensee evaluated the dose received by clinic staff working in the proximity of the package. Clinic staff does not work a full shift in the area (five hours maximum/day) and the closest estimated distance from the package was measured at 2 feet (60 cm). The exposure period was 5 working days. The licensee performed dose measurements on and near the source package at various distances and orientations with a survey meter. The maximum dose received was while sitting in a chair and was calculated to be 0.4 mR/hr.
"Total dose received was given as:
0.4 mR/hr * 5 hrs/day * 5 days = 10 mR total exposure (~10 mrem or 0.01 rem equivalent dose). This dose-risk standard was based upon National Council on Radiation Protection and Measurements (NCRP) Report No. 91.
"Cause and corrective actions :
"The two subsequent causes are of the same nature, human error. First, the carrier failed to deliver the package to the labeled destination and person. Second, the hospital clinic signed for the package without checking the proper destination or person it was intended for. A potential third cause of human error is that the licensee failed to check on package delivery sooner if a tracking number was associated with this shipment. Corrective actions have not been instituted at this time since not all information has been collected for this event. The licensee indicated that they receive these shipments quarterly and wait for the vendor to schedule an installation. There was no indication given of tracking a replacement source package while it is in transit to the licensee's site. This is being investigated further.
"Information regarding the source activity, manufacturer, model, serial number and leak test date will be provided to the NRC Headquarters Operation Center when it is received from the Licensee."
Oregon Report Identification Number: 22-0016
EN Revision Text: AGREEMENT STATE REPORT - LOST/RECOVERED SOURCE
The following information was provided by the Oregon Health Authority via email:
"On March 22, 2022, a High Dose Rate Delivery (HDR) sealed source of Iridium-192 was delivered by a common carrier to the wrong floor and clinic in a licensed (Salem Hospital) hospital. Instead of the shipping destination (given as Radiation Oncology/Attn: Dr xxx) on the 1st floor, the package was delivered to the 4th floor of the same building. The person receiving the package, who does not have radiation safety or transportation training, signed for it without an understanding of what it was and placed it on the floor of an access-controlled staff working area.
"On March 28, 2022, the licensee received an email request from the vendor (Varian) to schedule a date/time for installation of the new source. It was at this time that the licensee realized that the source had not arrived at their location and found the source had been delivered on March 22, 2022. An investigation was initiated and the source package was located in the 4th floor clinic. The package was surveyed and observed to be intact with no evidence of tampering . The transport index for the Type A Yellow -II package was noted at 0.9. The package was taken to the licensee's office and secured in locked storage.
"The licensee evaluated the dose received by clinic staff working in the proximity of the package. Clinic staff does not work a full shift in the area (five hours maximum/day) and the closest estimated distance from the package was measured at 2 feet (60 cm). The exposure period was 5 working days. The licensee performed dose measurements on and near the source package at various distances and orientations with a survey meter. The maximum dose received was while sitting in a chair and was calculated to be 0.4 mR/hr.
"Total dose received was given as:
0.4 mR/hr * 5 hrs/day * 5 days = 10 mR total exposure (~10 mrem or 0.01 rem equivalent dose). This dose-risk standard was based upon National Council on Radiation Protection and Measurements (NCRP) Report No. 91.
"Cause and corrective actions :
"The two subsequent causes are of the same nature, human error. First, the carrier failed to deliver the package to the labeled destination and person. Second, the hospital clinic signed for the package without checking the proper destination or person it was intended for. A potential third cause of human error is that the licensee failed to check on package delivery sooner if a tracking number was associated with this shipment. Corrective actions have not been instituted at this time since not all information has been collected for this event. The licensee indicated that they receive these shipments quarterly and wait for the vendor to schedule an installation. There was no indication given of tracking a replacement source package while it is in transit to the licensee's site. This is being investigated further.
"Information regarding the source activity, manufacturer, model, serial number and leak test date will be provided to the NRC Headquarters Operation Center when it is received from the Licensee."
Oregon Report Identification Number: 22-0016
Non-Agreement State
Event Number: 55813
Rep Org: Pearl Harbor Naval Shipyard IMF
Licensee: US Navy
Region: 1
City: Pearl Harbor State: HI
County:
License #: 45-23675-01NA
Agreement: N
Docket:
NRC Notified By: Mark Tamisharo
HQ OPS Officer: Lloyd Desotell
Licensee: US Navy
Region: 1
City: Pearl Harbor State: HI
County:
License #: 45-23675-01NA
Agreement: N
Docket:
NRC Notified By: Mark Tamisharo
HQ OPS Officer: Lloyd Desotell
Notification Date: 03/31/2022
Notification Time: 15:25 [ET]
Event Date: 03/30/2022
Event Time: 15:02 [HST]
Last Update Date: 04/01/2022
Notification Time: 15:25 [ET]
Event Date: 03/30/2022
Event Time: 15:02 [HST]
Last Update Date: 04/01/2022
Emergency Class: Non Emergency
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
10 CFR Section:
30.50(b)(2) - Safety Equipment Failure
Person (Organization):
Werkheiser, Dave (R1DO)
NMSS_Events_Notification, (EMAIL)
Werkheiser, Dave (R1DO)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: NON-AGREEMENT STATE REPORT - LEAKING SEALED SOURCE
The following information was provided by the licensee via phone:
The licensee reported that a generally licensed device has tested positive on a routine leak test (0.006 microCurie). The leaking sealed source was Ni-63 (15 milliCurie), which is used in an Agilent Gas Chromatograph (model G2397A). The gas chromatograph has been tagged out and no exposures were identified.
* * * UPDATE FROM MARK TAMASHIRO TO DONALD NORWOOD AT 1217 EDT ON 4/1/2022 * * *
The following information was received via E-mail:
"Please change the CFR reference to the subject call from 10 CFR 30.50(b)(2) to 10 CFR 31.5(c)(5)."
Notified R1DO (Werkheiser) and NMSS Events Notification E-mail group.
EN Revision Text: NON-AGREEMENT STATE REPORT - LEAKING SEALED SOURCE
The following information was provided by the licensee via phone:
The licensee reported that a generally licensed device has tested positive on a routine leak test (0.006 microCurie). The leaking sealed source was Ni-63 (15 milliCurie), which is used in an Agilent Gas Chromatograph (model G2397A). The gas chromatograph has been tagged out and no exposures were identified.
* * * UPDATE FROM MARK TAMASHIRO TO DONALD NORWOOD AT 1217 EDT ON 4/1/2022 * * *
The following information was received via E-mail:
"Please change the CFR reference to the subject call from 10 CFR 30.50(b)(2) to 10 CFR 31.5(c)(5)."
Notified R1DO (Werkheiser) and NMSS Events Notification E-mail group.
Agreement State
Event Number: 55814
Rep Org: WA Office of Radiation Protection
Licensee: Kaiser Permanente Bellevue
Region: 4
City: St. Bellevue State: WA
County:
License #: WN-M021
Agreement: Y
Docket:
NRC Notified By: Morgan Bullock
HQ OPS Officer: Lloyd Desotell
Licensee: Kaiser Permanente Bellevue
Region: 4
City: St. Bellevue State: WA
County:
License #: WN-M021
Agreement: Y
Docket:
NRC Notified By: Morgan Bullock
HQ OPS Officer: Lloyd Desotell
Notification Date: 03/31/2022
Notification Time: 20:48 [ET]
Event Date: 03/31/2022
Event Time: 00:00 [PDT]
Last Update Date: 03/31/2022
Notification Time: 20:48 [ET]
Event Date: 03/31/2022
Event Time: 00:00 [PDT]
Last Update Date: 03/31/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
CNSC (Canada), - (EMAIL)
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
CNSC (Canada), - (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: AGREEMENT STATE REPORT - LOST GD-153 SOURCE
The following was received from the Washington State Department of Health, Office of Radiation Protection, via email:
"The Washington Agreement State program was notified on 3/31/2022, about a lost source. Kaiser Permanente Bellevue lost a 10 mCi Gd-153 source. The source was in its leaded container in a shipping box and had not been processed in yet to the facility when housekeeping picked it up and threw it away. It then went to their own [trash] compactor and unfortunately was picked up by the garbage company. This event was only discovered a few hours ago.
"Washington State arrived onsite at Kaiser Bellevue at 1300 PDT and spoke with the Director of Imaging. Surveys of the garbage compactor [indicate that] the source is likely intact, as no contamination was found. The source is still lost, but is likely in the company garbage or landfill."
WA incident no.: WA-022-006
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT - LOST GD-153 SOURCE
The following was received from the Washington State Department of Health, Office of Radiation Protection, via email:
"The Washington Agreement State program was notified on 3/31/2022, about a lost source. Kaiser Permanente Bellevue lost a 10 mCi Gd-153 source. The source was in its leaded container in a shipping box and had not been processed in yet to the facility when housekeeping picked it up and threw it away. It then went to their own [trash] compactor and unfortunately was picked up by the garbage company. This event was only discovered a few hours ago.
"Washington State arrived onsite at Kaiser Bellevue at 1300 PDT and spoke with the Director of Imaging. Surveys of the garbage compactor [indicate that] the source is likely intact, as no contamination was found. The source is still lost, but is likely in the company garbage or landfill."
WA incident no.: WA-022-006
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 55821
Facility: Nine Mile Point
Region: 1 State: NY
Unit: [2] [] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: Roman Arnold
HQ OPS Officer: Ossy Font
Region: 1 State: NY
Unit: [2] [] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: Roman Arnold
HQ OPS Officer: Ossy Font
Notification Date: 04/05/2022
Notification Time: 06:08 [ET]
Event Date: 04/05/2022
Event Time: 02:23 [EDT]
Last Update Date: 04/05/2022
Notification Time: 06:08 [ET]
Event Date: 04/05/2022
Event Time: 02:23 [EDT]
Last Update Date: 04/05/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(A) - Eccs Injection 50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(2)(iv)(A) - Eccs Injection 50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Defrancisco, Anne (R1DO)
Defrancisco, Anne (R1DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
EN Revision Imported Date: 4/7/2022
EN Revision Text: SCRAM ON LOW LEVEL
The following information was provided by the licensee via telephone and email:
"On 4/5/2022, at time 0223, during maintenance on Feedwater Level Control Valve 2FWS-LV10B, a Feedwater transient occurred resulting in an RPS Automatic Reactor Scram on Low Level (Level 3, 159.3 inches). Following the scram, reactor water level dropped below Level 2 (108.8 inches) resulting in a Group 2 Recirculation Sample System Isolation, Group 3 TIP [(Traversing Incore Probe)] Isolation Valve Isolation, Group 6 and 7 Reactor Water Cleanup Isolation and Group 9 Containment Purge Isolations.
"All control rods inserted as expected. High Pressure Core Spray and Reactor Core Isolation Cooling initiated and injected as expected. ECCS Systems have been secured and normal reactor pressure and level control has been established for hot shutdown. Nine Mile Point Unit 2 is stable in Mode 3.
"These 4 hour and 8-hour non-emergency ENS [(Emergency Notification System)] reports are being made in accordance with 10 CFR 50.72(b)(2)(iv)(A), 10 CFR 50.72(b)(2)(iv)(B), and 10 CFR 50.72(b)(3)(iv)(A).
"The NRC Resident was informed."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
There was no impact on Unit 1.
EN Revision Text: SCRAM ON LOW LEVEL
The following information was provided by the licensee via telephone and email:
"On 4/5/2022, at time 0223, during maintenance on Feedwater Level Control Valve 2FWS-LV10B, a Feedwater transient occurred resulting in an RPS Automatic Reactor Scram on Low Level (Level 3, 159.3 inches). Following the scram, reactor water level dropped below Level 2 (108.8 inches) resulting in a Group 2 Recirculation Sample System Isolation, Group 3 TIP [(Traversing Incore Probe)] Isolation Valve Isolation, Group 6 and 7 Reactor Water Cleanup Isolation and Group 9 Containment Purge Isolations.
"All control rods inserted as expected. High Pressure Core Spray and Reactor Core Isolation Cooling initiated and injected as expected. ECCS Systems have been secured and normal reactor pressure and level control has been established for hot shutdown. Nine Mile Point Unit 2 is stable in Mode 3.
"These 4 hour and 8-hour non-emergency ENS [(Emergency Notification System)] reports are being made in accordance with 10 CFR 50.72(b)(2)(iv)(A), 10 CFR 50.72(b)(2)(iv)(B), and 10 CFR 50.72(b)(3)(iv)(A).
"The NRC Resident was informed."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
There was no impact on Unit 1.
Agreement State
Event Number: 55815
Rep Org: SC Dept of Health & Env Control
Licensee: Southern Felt Company Inc.
Region: 1
City: Bethune State: SC
County:
License #: GL
Agreement: Y
Docket:
NRC Notified By: Korina Koci
HQ OPS Officer: Brian Lin
Licensee: Southern Felt Company Inc.
Region: 1
City: Bethune State: SC
County:
License #: GL
Agreement: Y
Docket:
NRC Notified By: Korina Koci
HQ OPS Officer: Brian Lin
Notification Date: 04/01/2022
Notification Time: 09:42 [ET]
Event Date: 03/30/2022
Event Time: 00:00 [EDT]
Last Update Date: 04/01/2022
Notification Time: 09:42 [ET]
Event Date: 03/30/2022
Event Time: 00:00 [EDT]
Last Update Date: 04/01/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Werkheiser, Dave (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Werkheiser, Dave (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: AGREEMENT STATE REPORT - FAILED INDICATOR
The following information was received from the South Carolina Department of Health and Environmental Control via email:
"During a routine inspection of a licensee's specific license on 03/23/22, the South Carolina Department of Health and Environmental Control was informed that a generally licensed fixed gauging device (80 milliCurie, Kr-85, Mahlo Model 6270, serial number PH847) had a failed indicator and had been repaired by the manufacturer on 01/11/22. Dose rate surveys of the fixed gauging device were performed by Department inspectors and indicated readings below the external radiation levels outlined in the sealed source and device registry certificate. The licensee submitted a written notification of the event to the Department on 03/30/22. This event is still under investigation by the South Carolina Department of Health and Environmental Control."
EN Revision Text: AGREEMENT STATE REPORT - FAILED INDICATOR
The following information was received from the South Carolina Department of Health and Environmental Control via email:
"During a routine inspection of a licensee's specific license on 03/23/22, the South Carolina Department of Health and Environmental Control was informed that a generally licensed fixed gauging device (80 milliCurie, Kr-85, Mahlo Model 6270, serial number PH847) had a failed indicator and had been repaired by the manufacturer on 01/11/22. Dose rate surveys of the fixed gauging device were performed by Department inspectors and indicated readings below the external radiation levels outlined in the sealed source and device registry certificate. The licensee submitted a written notification of the event to the Department on 03/30/22. This event is still under investigation by the South Carolina Department of Health and Environmental Control."
Agreement State
Event Number: 55816
Rep Org: Louisiana Radiation Protection Div
Licensee: Inspection Specialist Inc.
Region: 4
City: Marrero State: LA
County:
License #: LA-4266-L01
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Brian Lin
Licensee: Inspection Specialist Inc.
Region: 4
City: Marrero State: LA
County:
License #: LA-4266-L01
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Brian Lin
Notification Date: 04/01/2022
Notification Time: 11:07 [ET]
Event Date: 04/01/2022
Event Time: 00:00 [CDT]
Last Update Date: 04/01/2022
Notification Time: 11:07 [ET]
Event Date: 04/01/2022
Event Time: 00:00 [CDT]
Last Update Date: 04/01/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Deese, Rick (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: AGREEMENT STATE REPORT - SOURCE DISCONNECT OF AN INDUSTRIAL RADIOGRAPHY CAMERA
The following information was received from the Louisiana Department of Environmental Quality (LDEQ) via email:
"On April 1, 2022, LDEQ received this event notification. The licensee was working at Bayer Crop Science, LP performing industrial radiography work on March 28, 2022. At approximately 1051 CDT, the RSO [(Radiation Safety Officer)] was notified of a source disconnect. The event involved a QSA 880 Delta, serial number 7511, source serial number 4806514. The source was an Ir-192 with an activity of 59 Ci. The drive cable end connector had broken off from the drive cable. The source was retrieved back into a shielded condition.
"The person performing the source retrieval received 460 mR exposure.
"The radiographer involved had his pocket ion chamber go off scale and his badge was sent in. The badge read 337 mR which was at the end of the working month."
Louisiana Event Report ID No.: LA 20220004
EN Revision Text: AGREEMENT STATE REPORT - SOURCE DISCONNECT OF AN INDUSTRIAL RADIOGRAPHY CAMERA
The following information was received from the Louisiana Department of Environmental Quality (LDEQ) via email:
"On April 1, 2022, LDEQ received this event notification. The licensee was working at Bayer Crop Science, LP performing industrial radiography work on March 28, 2022. At approximately 1051 CDT, the RSO [(Radiation Safety Officer)] was notified of a source disconnect. The event involved a QSA 880 Delta, serial number 7511, source serial number 4806514. The source was an Ir-192 with an activity of 59 Ci. The drive cable end connector had broken off from the drive cable. The source was retrieved back into a shielded condition.
"The person performing the source retrieval received 460 mR exposure.
"The radiographer involved had his pocket ion chamber go off scale and his badge was sent in. The badge read 337 mR which was at the end of the working month."
Louisiana Event Report ID No.: LA 20220004
Non-Agreement State
Event Number: 55817
Rep Org: Ind Univ-IUPUI/IU Med Center Campus
Licensee: Ind Univ-IUPUI/IU Med Center Campus
Region: 3
City: Indianapolis State: IN
County:
License #: 13-02752-03
Agreement: N
Docket:
NRC Notified By: Michael Martin
HQ OPS Officer: Donald Norwood
Licensee: Ind Univ-IUPUI/IU Med Center Campus
Region: 3
City: Indianapolis State: IN
County:
License #: 13-02752-03
Agreement: N
Docket:
NRC Notified By: Michael Martin
HQ OPS Officer: Donald Norwood
Notification Date: 04/01/2022
Notification Time: 14:25 [ET]
Event Date: 03/31/2022
Event Time: 00:00 [EDT]
Last Update Date: 04/01/2022
Notification Time: 14:25 [ET]
Event Date: 03/31/2022
Event Time: 00:00 [EDT]
Last Update Date: 04/01/2022
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
10 CFR Section:
20.2201(a)(1)(i) - Lost/Stolen LNM>1000x
Person (Organization):
Kozak, Laura (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Kozak, Laura (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: NON-AGREEMENT STATE REPORT - LOST MEDICAL DOSE
The following information was provided by the licensee via telephone and email:
"Two clinical doses of Xofigo [(radium (Ra-223) dichloride, 119 microcuries)] were delivered to the Nuclear Medicine department on 3/31/2022. A patient scheduled for one of the doses on Thursday 3/31/2022 was successfully administered with the activity. A second patient was scheduled to receive the second dose on 4/1/2022 at 1300 EDT.
"At scheduled time, the Nuclear Medicine technologists could not locate the second dose. After a thorough search, the RSO [(Radiation Safety Officer)] was notified. It is suspected that the second dose was accidentally disposed of in the box in which both doses were received.
"The first dose was properly disposed of in a radioactive sharps container, and the second dose remained in the delivery box within the secured hot lab area. It is suspected that a nuclear medicine technologist threw the box away without realizing a second dose was inside, as it is an extremely rare occurrence for two doses to be delivered concurrently. The dose was not detected during the end of day survey nor by portal monitoring at the waste facility, due to the relatively low activity and low yield of x-rays/gamma-rays (Ra-223 is primarily an alpha emitter)."
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: NON-AGREEMENT STATE REPORT - LOST MEDICAL DOSE
The following information was provided by the licensee via telephone and email:
"Two clinical doses of Xofigo [(radium (Ra-223) dichloride, 119 microcuries)] were delivered to the Nuclear Medicine department on 3/31/2022. A patient scheduled for one of the doses on Thursday 3/31/2022 was successfully administered with the activity. A second patient was scheduled to receive the second dose on 4/1/2022 at 1300 EDT.
"At scheduled time, the Nuclear Medicine technologists could not locate the second dose. After a thorough search, the RSO [(Radiation Safety Officer)] was notified. It is suspected that the second dose was accidentally disposed of in the box in which both doses were received.
"The first dose was properly disposed of in a radioactive sharps container, and the second dose remained in the delivery box within the secured hot lab area. It is suspected that a nuclear medicine technologist threw the box away without realizing a second dose was inside, as it is an extremely rare occurrence for two doses to be delivered concurrently. The dose was not detected during the end of day survey nor by portal monitoring at the waste facility, due to the relatively low activity and low yield of x-rays/gamma-rays (Ra-223 is primarily an alpha emitter)."
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Part 21
Event Number: 55827
Rep Org: Curtiss Wright Flow Control Co.
Licensee: Tennessee Valley Authority
Region: 3
City: Cincinnati State: OH
County:
License #:
Agreement: N
Docket:
NRC Notified By: Margie Hover
HQ OPS Officer: Brian Lin
Licensee: Tennessee Valley Authority
Region: 3
City: Cincinnati State: OH
County:
License #:
Agreement: N
Docket:
NRC Notified By: Margie Hover
HQ OPS Officer: Brian Lin
Notification Date: 04/07/2022
Notification Time: 15:15 [ET]
Event Date: 02/07/2022
Event Time: 00:00 [EDT]
Last Update Date: 04/07/2022
Notification Time: 15:15 [ET]
Event Date: 02/07/2022
Event Time: 00:00 [EDT]
Last Update Date: 04/07/2022
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Miller, Mark (R2DO)
McCraw, Aaron (R3DO)
Part 21/50.55 Reactors, - (EMAIL)
Miller, Mark (R2DO)
McCraw, Aaron (R3DO)
Part 21/50.55 Reactors, - (EMAIL)
EN Revision Imported Date: 4/8/2022
EN Revision Text: PART 21 - CURTISS-WRIGHT ACTUATOR BRAKE WIRING DEFICENCY REPORT
The following information was provided by Curtiss-Wright Nuclear Division via fax:
"The Tennessee Valley Authority (TVA) Browns Ferry Plant notified us (QualTech NP, Curtiss-Wright Nuclear Division) of two separate RCS/Dresser actuator failures which we had provided as safety related components. According to TVA, the first failure occurred on February 7, 2022, after being installed for approximately 167 days. The 2nd failure occurred on February 9, 2022, and was in service for approximately 24 hours when it failed.
"According to TVA in both cases the actuator's brake assembly wire harness shorted out to the frame, causing the on-board fuse to blow, disabling the actuator. The electrical short was caused by the wire harness laying against a sharp edge of the metal frame, which over time led to fraying of the wire insulation and subsequent bare wire to frame contact.
"Both units were returned to QualTech NP for evaluation and our findings confirmed TVA's assessment.
"The root cause of the issue is friction between the wires and the sharp metallic edge that over time cut through the insulation via vibration, which in turn shorted the power leads to the frame. This shorting effect was due to poor positioning and restraint of the wire harness/bundle by the manufacturer during assembly. It is not considered a design flaw, but a workmanship issue caused by the factory assembler.
"The corrective action taken with the two units was to install new brake assemblies and reposition the wire harness to prevent contact with the sharp edge. In addition, wire ties were added to restrain the wire's movement and keep it away from the sharp edge. As a follow up action, the associated dedication plan will be revised to inspect for this workmanship issue and correct as needed.
"Additional details are provided in the failure evaluation. QualTech NP has only sold this part to TVA (Browns Ferry) and could not find any additional failures of this type reported by the industry. Identification of the customer's orders and hardware involved are provided in the evaluation.
"Please phone (513) 528-7900 if you should have any questions."
EN Revision Text: PART 21 - CURTISS-WRIGHT ACTUATOR BRAKE WIRING DEFICENCY REPORT
The following information was provided by Curtiss-Wright Nuclear Division via fax:
"The Tennessee Valley Authority (TVA) Browns Ferry Plant notified us (QualTech NP, Curtiss-Wright Nuclear Division) of two separate RCS/Dresser actuator failures which we had provided as safety related components. According to TVA, the first failure occurred on February 7, 2022, after being installed for approximately 167 days. The 2nd failure occurred on February 9, 2022, and was in service for approximately 24 hours when it failed.
"According to TVA in both cases the actuator's brake assembly wire harness shorted out to the frame, causing the on-board fuse to blow, disabling the actuator. The electrical short was caused by the wire harness laying against a sharp edge of the metal frame, which over time led to fraying of the wire insulation and subsequent bare wire to frame contact.
"Both units were returned to QualTech NP for evaluation and our findings confirmed TVA's assessment.
"The root cause of the issue is friction between the wires and the sharp metallic edge that over time cut through the insulation via vibration, which in turn shorted the power leads to the frame. This shorting effect was due to poor positioning and restraint of the wire harness/bundle by the manufacturer during assembly. It is not considered a design flaw, but a workmanship issue caused by the factory assembler.
"The corrective action taken with the two units was to install new brake assemblies and reposition the wire harness to prevent contact with the sharp edge. In addition, wire ties were added to restrain the wire's movement and keep it away from the sharp edge. As a follow up action, the associated dedication plan will be revised to inspect for this workmanship issue and correct as needed.
"Additional details are provided in the failure evaluation. QualTech NP has only sold this part to TVA (Browns Ferry) and could not find any additional failures of this type reported by the industry. Identification of the customer's orders and hardware involved are provided in the evaluation.
"Please phone (513) 528-7900 if you should have any questions."
Power Reactor
Event Number: 55828
Facility: Surry
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Alan Bidlowas
HQ OPS Officer: Thomas Herrity
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Alan Bidlowas
HQ OPS Officer: Thomas Herrity
Notification Date: 04/07/2022
Notification Time: 16:12 [ET]
Event Date: 04/07/2022
Event Time: 09:09 [EDT]
Last Update Date: 04/07/2022
Notification Time: 16:12 [ET]
Event Date: 04/07/2022
Event Time: 09:09 [EDT]
Last Update Date: 04/07/2022
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Miller, Mark (R2DO)
FFD Group, (EMAIL)
Miller, Mark (R2DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
EN Revision Imported Date: 4/8/2022
EN Revision Text: FITNESS-FOR-DUTY REPORT - FAILED FITNESS-FOR-DUTY TEST
The following information was provided by the licensee via phone call:
"At 0909 EDT on 4/7/2022, it was determined that a security officer tested positive during a random fitness-for-duty test. The individual's authorization for site access has been terminated.
"The NRC Resident Inspector has been notified."
EN Revision Text: FITNESS-FOR-DUTY REPORT - FAILED FITNESS-FOR-DUTY TEST
The following information was provided by the licensee via phone call:
"At 0909 EDT on 4/7/2022, it was determined that a security officer tested positive during a random fitness-for-duty test. The individual's authorization for site access has been terminated.
"The NRC Resident Inspector has been notified."