Event Notification Report for March 23, 2022
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/22/2022 - 03/23/2022
Agreement State
Event Number: 55789
Rep Org: Alabama Radiation Control
Licensee: National Cement Co. of Alabama, Inc
Region: 1
City: Ragland State: AL
County:
License #: 799
Agreement: Y
Docket:
NRC Notified By: Cason Coan
HQ OPS Officer: Donald Norwood
Licensee: National Cement Co. of Alabama, Inc
Region: 1
City: Ragland State: AL
County:
License #: 799
Agreement: Y
Docket:
NRC Notified By: Cason Coan
HQ OPS Officer: Donald Norwood
Notification Date: 03/15/2022
Notification Time: 16:16 [ET]
Event Date: 03/15/2022
Event Time: 00:00 [CST]
Last Update Date: 03/15/2022
Notification Time: 16:16 [ET]
Event Date: 03/15/2022
Event Time: 00:00 [CST]
Last Update Date: 03/15/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 3/23/2022
EN Revision Text: AGREEMENT STATE REPORT - FIXED GAUGE WITH STUCK SHUTTER
The following information was received from the Alabama Office of Radiation Control via E-mail:
"The Alabama Office of Radiation Control received a call from a service provider on 3/15/2022 to report a fixed gauge with the shutter stuck in the open position. The licensee is National Cement Company of Alabama, Inc. in Ragland, Alabama. The gauge is a Vega Americas SR-1A gauge, s/n 8180GK, with nominal 500 millicuries of cesium-137. The service provider shielded the gauge with a 4 inch steel plate, resulting in an exposure rate of 0.1 mR/hr at the surface. No unmonitored personnel are known to have been exposed as a result of the stuck shutter. Report to follow as required."
Alabama Event: 22-05
EN Revision Text: AGREEMENT STATE REPORT - FIXED GAUGE WITH STUCK SHUTTER
The following information was received from the Alabama Office of Radiation Control via E-mail:
"The Alabama Office of Radiation Control received a call from a service provider on 3/15/2022 to report a fixed gauge with the shutter stuck in the open position. The licensee is National Cement Company of Alabama, Inc. in Ragland, Alabama. The gauge is a Vega Americas SR-1A gauge, s/n 8180GK, with nominal 500 millicuries of cesium-137. The service provider shielded the gauge with a 4 inch steel plate, resulting in an exposure rate of 0.1 mR/hr at the surface. No unmonitored personnel are known to have been exposed as a result of the stuck shutter. Report to follow as required."
Alabama Event: 22-05
Agreement State
Event Number: 55790
Rep Org: Mississippi Div of Rad Health
Licensee: Leaf River Cellulose
Region: 4
City: New Agusta State: MS
County:
License #: MS-565-02
Agreement: Y
Docket:
NRC Notified By: Robert Sims
HQ OPS Officer: Donald Norwood
Licensee: Leaf River Cellulose
Region: 4
City: New Agusta State: MS
County:
License #: MS-565-02
Agreement: Y
Docket:
NRC Notified By: Robert Sims
HQ OPS Officer: Donald Norwood
Notification Date: 03/15/2022
Notification Time: 17:20 [ET]
Event Date: 03/15/2022
Event Time: 00:00 [CST]
Last Update Date: 03/15/2022
Notification Time: 17:20 [ET]
Event Date: 03/15/2022
Event Time: 00:00 [CST]
Last Update Date: 03/15/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 3/23/2022
EN Revision Text: AGREEMENT STATE REPORT - FIXED GAUGE LOCKING PIN STUCK
The following information was received from the Mississippi State Department of Radiological Health via E-mail:
"During locking out the device for shutdown of the operating equipment, the key that locks the locking pin to the shutter broke when the shutter was put in the closed position. The key will not remove the pin. Berthold was contacted to have this pin replaced. The device is inoperable but safe to be around since the shutter is closed and the locking pin is stuck.
"Manufacture: Berthold
Model: LB 7400D/F
Gauge Serial Number: 2967-11-95
Capsule Serial Number: N/A 16072
Material: Cs-137
Activity: 150 mCi"
Mississippi Incident: MS-220001
EN Revision Text: AGREEMENT STATE REPORT - FIXED GAUGE LOCKING PIN STUCK
The following information was received from the Mississippi State Department of Radiological Health via E-mail:
"During locking out the device for shutdown of the operating equipment, the key that locks the locking pin to the shutter broke when the shutter was put in the closed position. The key will not remove the pin. Berthold was contacted to have this pin replaced. The device is inoperable but safe to be around since the shutter is closed and the locking pin is stuck.
"Manufacture: Berthold
Model: LB 7400D/F
Gauge Serial Number: 2967-11-95
Capsule Serial Number: N/A 16072
Material: Cs-137
Activity: 150 mCi"
Mississippi Incident: MS-220001
Agreement State
Event Number: 55791
Rep Org: OK Deq Rad Management
Licensee: Acuren Inspection, Inc.
Region: 4
City: Tulsa State: OK
County:
License #: OK-32148-01
Agreement: Y
Docket:
NRC Notified By: Kevin Sampson
HQ OPS Officer: Karen Cotton-Gross
Licensee: Acuren Inspection, Inc.
Region: 4
City: Tulsa State: OK
County:
License #: OK-32148-01
Agreement: Y
Docket:
NRC Notified By: Kevin Sampson
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 03/16/2022
Notification Time: 11:18 [ET]
Event Date: 03/12/2022
Event Time: 00:00 [CST]
Last Update Date: 03/16/2022
Notification Time: 11:18 [ET]
Event Date: 03/12/2022
Event Time: 00:00 [CST]
Last Update Date: 03/16/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 3/24/2022
EN Revision Text: AGREEMENT STATE REPORT - RADIOGRAPHY SOURCE FAILURE TO RETRACT
The following information was provided by the Oklahoma Department of Environmental Quality via email:
"Today we received a report of an industrial radiography equipment failure which occurred on March 12, 2022. The licensee is Acuren Inspection, Inc. (OK-32148-01). The incident was caused by the failure of the drive cable. Acuren is licensed to perform source recoveries and the source was eventually retracted into the camera safely. The crew's dosimeters have been sent for processing. Pocket dosimeter readings indicate the dose received due to this incident was approximately 135 mR. We will provide details of the equipment involved when we receive them from the licensee."
EN Revision Text: AGREEMENT STATE REPORT - RADIOGRAPHY SOURCE FAILURE TO RETRACT
The following information was provided by the Oklahoma Department of Environmental Quality via email:
"Today we received a report of an industrial radiography equipment failure which occurred on March 12, 2022. The licensee is Acuren Inspection, Inc. (OK-32148-01). The incident was caused by the failure of the drive cable. Acuren is licensed to perform source recoveries and the source was eventually retracted into the camera safely. The crew's dosimeters have been sent for processing. Pocket dosimeter readings indicate the dose received due to this incident was approximately 135 mR. We will provide details of the equipment involved when we receive them from the licensee."
Power Reactor
Event Number: 55750
Facility: Oconee
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: Carl Seymour
HQ OPS Officer: Brian P. Smith
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: Carl Seymour
HQ OPS Officer: Brian P. Smith
Notification Date: 02/22/2022
Notification Time: 01:44 [ET]
Event Date: 02/21/2022
Event Time: 22:07 [EST]
Last Update Date: 03/23/2022
Notification Time: 01:44 [ET]
Event Date: 02/21/2022
Event Time: 22:07 [EST]
Last Update Date: 03/23/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Miller, Mark (R2)
Miller, Mark (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | M/R | Y | 68 | Power Operation | 0 | Hot Standby |
EN Revision Imported Date: 3/24/2022
EN Revision Text: MANUAL REACTOR TRIP
The following information was provided by the licensee via fax or email:
"At 2207 [EST] on 2/21/2022 with Unit 2 in Mode 1 at 68 percent power, the reactor was manually tripped due to lowering water level in the 2A Steam Generator. The trip was not complex with all systems responding normally post-trip.
"Operators responded and stabilized the plant. Decay heat is being removed by discharging steam to the main condenser using the turbine bypass valves. Units 1 and 3 were not affected.
"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non- emergency notification per 10 CFR 50.72(b)(2)(iv)(B).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
* * * UPDATE ON 3/23/22 AT 1643 EDT FROM CHRIS MCDUFFIE TO TOM KENDZIA * * *
The following information was provided by the licensee via phone and email:
"On 2/21/2022, Unit 2 was in Mode 1 increasing reactor power following startup from a forced outage. At 2205 [EST] with Unit 2 at 68 percent power, a feedwater control valve failed to properly control feedwater flow to the 2A Steam Generator and the Integrated Control System initiated an automatic runback. At 2207 [EST], the reactor was manually tripped from 39 percent power due to lowering water level in the 2A Steam Generator. Immediately following the manual reactor trip, an actuation of the Emergency Feedwater System (EFW) occurred. The 2A and 2B Motor Driven Emergency Feedwater (MDEFW) pumps automatically started as designed when the 'low steam generator level' signal was received for the 2A Steam Generator. The trip was not complex with all systems responding normally post-trip. Operators responded and stabilized the plant. Decay heat was removed by discharging steam to the main condenser using the turbine bypass valves. Units 1 and 3 were not affected. Unit 2 was restarted on 2/27/2022 following repairs.
"Due to the Reactor Protection System actuation while critical, this event was reported on 2/22/2022 as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B). Following further evaluation, it was determined that a valid EFW actuation occurred, therefore this event is now also being reported as a late 8-hour non-emergency notification of a valid actuation of the EFW system in accordance with 10 CFR 50.72(b)(3)(iv)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
Notified the R2DO (Miller).
EN Revision Text: MANUAL REACTOR TRIP
The following information was provided by the licensee via fax or email:
"At 2207 [EST] on 2/21/2022 with Unit 2 in Mode 1 at 68 percent power, the reactor was manually tripped due to lowering water level in the 2A Steam Generator. The trip was not complex with all systems responding normally post-trip.
"Operators responded and stabilized the plant. Decay heat is being removed by discharging steam to the main condenser using the turbine bypass valves. Units 1 and 3 were not affected.
"Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non- emergency notification per 10 CFR 50.72(b)(2)(iv)(B).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
* * * UPDATE ON 3/23/22 AT 1643 EDT FROM CHRIS MCDUFFIE TO TOM KENDZIA * * *
The following information was provided by the licensee via phone and email:
"On 2/21/2022, Unit 2 was in Mode 1 increasing reactor power following startup from a forced outage. At 2205 [EST] with Unit 2 at 68 percent power, a feedwater control valve failed to properly control feedwater flow to the 2A Steam Generator and the Integrated Control System initiated an automatic runback. At 2207 [EST], the reactor was manually tripped from 39 percent power due to lowering water level in the 2A Steam Generator. Immediately following the manual reactor trip, an actuation of the Emergency Feedwater System (EFW) occurred. The 2A and 2B Motor Driven Emergency Feedwater (MDEFW) pumps automatically started as designed when the 'low steam generator level' signal was received for the 2A Steam Generator. The trip was not complex with all systems responding normally post-trip. Operators responded and stabilized the plant. Decay heat was removed by discharging steam to the main condenser using the turbine bypass valves. Units 1 and 3 were not affected. Unit 2 was restarted on 2/27/2022 following repairs.
"Due to the Reactor Protection System actuation while critical, this event was reported on 2/22/2022 as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B). Following further evaluation, it was determined that a valid EFW actuation occurred, therefore this event is now also being reported as a late 8-hour non-emergency notification of a valid actuation of the EFW system in accordance with 10 CFR 50.72(b)(3)(iv)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
Notified the R2DO (Miller).
Agreement State
Event Number: 55792
Rep Org: PA Bureau of Radiation Protection
Licensee: D'Appolonia Engr, Inc.
Region: 1
City: Pittsburgh State: PA
County:
License #: PA-1241
Agreement: Y
Docket:
NRC Notified By: Joshua M. Myers
HQ OPS Officer: Karen Cotton-Gross
Licensee: D'Appolonia Engr, Inc.
Region: 1
City: Pittsburgh State: PA
County:
License #: PA-1241
Agreement: Y
Docket:
NRC Notified By: Joshua M. Myers
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 03/17/2022
Notification Time: 11:29 [ET]
Event Date: 03/16/2022
Event Time: 00:00 [EST]
Last Update Date: 03/17/2022
Notification Time: 11:29 [ET]
Event Date: 03/16/2022
Event Time: 00:00 [EST]
Last Update Date: 03/17/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Henrion, Mark (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 3/24/2022
EN Revision Text: AGREEMENT STATE REPORT- LOSS/MISDELIVERY OF NUCLEAR DENSITY GAUGE
The following information was provided by the Pennsylvania Department Bureau of Radiation Protection (Department) via email:
"On March 16, 2022, the licensee informed the Department of an event that is reportable per 10 CFR 20.2201(a)(1)(i).
"The Department received notification from a licensee on March 16, 2022, that a Troxler 3440 portable gauge (serial number 62679) was delivered to the wrong location and to the wrong licensee. The gauge contains 9 mCi of Cs-137 and 44 mCi of Am-241:Be. The gauge was incorrectly delivered to KU Resources, another Pennsylvania licensee (PA-1247), by [the common carrier]. The device was on its way back from being serviced by commercial vendor, lnstroTek (PA-1522). KU Resources also had gauge(s) at lnstroTek for service. KU Resources has secured the device in its vault while the carrier and service provider arrange proper delivery back to the proper licensee.
"The cause of the event is unknown at this time. The Department will perform a reactive inspection as soon as possible."
Pennsylvania Event Number: PA220011
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
EN Revision Text: AGREEMENT STATE REPORT- LOSS/MISDELIVERY OF NUCLEAR DENSITY GAUGE
The following information was provided by the Pennsylvania Department Bureau of Radiation Protection (Department) via email:
"On March 16, 2022, the licensee informed the Department of an event that is reportable per 10 CFR 20.2201(a)(1)(i).
"The Department received notification from a licensee on March 16, 2022, that a Troxler 3440 portable gauge (serial number 62679) was delivered to the wrong location and to the wrong licensee. The gauge contains 9 mCi of Cs-137 and 44 mCi of Am-241:Be. The gauge was incorrectly delivered to KU Resources, another Pennsylvania licensee (PA-1247), by [the common carrier]. The device was on its way back from being serviced by commercial vendor, lnstroTek (PA-1522). KU Resources also had gauge(s) at lnstroTek for service. KU Resources has secured the device in its vault while the carrier and service provider arrange proper delivery back to the proper licensee.
"The cause of the event is unknown at this time. The Department will perform a reactive inspection as soon as possible."
Pennsylvania Event Number: PA220011
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55793
Rep Org: Arkansas Department of Health
Licensee: Anchor Packaging Company
Region: 4
City: Paragould State: AR
County:
License #: GL-0010
Agreement: Y
Docket:
NRC Notified By: Christy Steward
HQ OPS Officer: Donald Norwood
Licensee: Anchor Packaging Company
Region: 4
City: Paragould State: AR
County:
License #: GL-0010
Agreement: Y
Docket:
NRC Notified By: Christy Steward
HQ OPS Officer: Donald Norwood
Notification Date: 03/17/2022
Notification Time: 11:30 [ET]
Event Date: 03/02/2022
Event Time: 00:00 [CST]
Last Update Date: 03/22/2022
Notification Time: 11:30 [ET]
Event Date: 03/02/2022
Event Time: 00:00 [CST]
Last Update Date: 03/22/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Drake, James (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
EN Revision Imported Date: 3/24/2022
EN Revision Text: AGREEMENT STATE REPORT - FOUND AM-241 SOURCE
The following information was received via E-mail from the Arkansas Department of Health (ADH):
"WW Recycling in Marmaduke, Arkansas, reported to Arkansas Radiation Control Program on March 2, 2022, that they believed a source had been found in scrap metal unloaded at their facility. At the time of the report, they were unable to identify the customer from whom the scrap metal was purchased.
"Intact labeling provided general license information, Am-241, manufactured by NDC in California, source SN 7090AR, Model 103, 5.55 GBq (150 mCi) in April 2011. The device manufacturer identified the device and tracked its shipment to Arkansas' GL-0010, Anchor Packaging Company located in Paragould, Arkansas.
"Radiation surveys conducted by recycling facility personnel indicated a reading of 10 microR/hr at approximately three feet from the item.
"Health Physicists from the Arkansas Radiation Control Program responded to WW Recycling on the morning of March 3, 2022.
"A metal drum container clearly labeled with a radioactive material sign, observed to be closed, in good repair was surveyed by ADH personnel. The top of the metal drum registered 185 microR/hr. The reading at the bottom sealed edge of the drum reached 85 milliR/hr. The shutter appears to be missing. There are no known exposures.
"The device remains secured at the recycling center and this event remains open while Anchor GL-0010 pursues disposal through a specific licensee authorized to perform this sort of activity/retrieval.
"Reporting Requirement: Arkansas State Board of Health Rules for Control of Sources of Ionizing Radiation RH-402.c.5. and 10 CFR Part 31.5(c)(5)."
State Event Report ID No.: AR-2022-04
* * * UPDATE ON 3/22/2022 AT 1534 EDT FROM CHRISTY STEWARD TO BRIAN LIN * * *
"On March 17, 2022, WW Recycling in Marmaduke, Arkansas, contacted the Arkansas Department of Health - Radiation Control Section to report the discovery of a second gauge. Photos received March 18, 2022, confirm this gauge to be similar to the generally licensed fixed gauge discovered then reported to the Department on March 2, 2022 (NDC model 103X, SN 13629, Am-241, 5.55 GBq). SN 13629 was once registered to Anchor Packaging Company in Paragould, Arkansas, and later documented as disposed. The gauge was found in the remnants of the original load where the first gauge was found. The gauge was placed into a radioactive material - labeled small drum and secured in the remote storage building where the initial gauge is being stored (also in a small drum).
"WW Recycling personnel measured 40 microR/hr, via their Ludlum 193-6, on contact with the outside of the wall closest to the two drums. Inside the building, about 7 feet away from the drums, radiation levels begin increasing above background. The photo indicates the shutter to be attached but not closed. There are no known exposures.
"Reporting requirements: Arkansas State Board of Health Rules for Control of Sources of Ionizing Radiation - RH-1501.a.1.A. and RH-1501.b. pursuant to RH-409.c.10. "
Notified R4DO (Taylor), and NMSS Events Notification via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf.
EN Revision Text: AGREEMENT STATE REPORT - FOUND AM-241 SOURCE
The following information was received via E-mail from the Arkansas Department of Health (ADH):
"WW Recycling in Marmaduke, Arkansas, reported to Arkansas Radiation Control Program on March 2, 2022, that they believed a source had been found in scrap metal unloaded at their facility. At the time of the report, they were unable to identify the customer from whom the scrap metal was purchased.
"Intact labeling provided general license information, Am-241, manufactured by NDC in California, source SN 7090AR, Model 103, 5.55 GBq (150 mCi) in April 2011. The device manufacturer identified the device and tracked its shipment to Arkansas' GL-0010, Anchor Packaging Company located in Paragould, Arkansas.
"Radiation surveys conducted by recycling facility personnel indicated a reading of 10 microR/hr at approximately three feet from the item.
"Health Physicists from the Arkansas Radiation Control Program responded to WW Recycling on the morning of March 3, 2022.
"A metal drum container clearly labeled with a radioactive material sign, observed to be closed, in good repair was surveyed by ADH personnel. The top of the metal drum registered 185 microR/hr. The reading at the bottom sealed edge of the drum reached 85 milliR/hr. The shutter appears to be missing. There are no known exposures.
"The device remains secured at the recycling center and this event remains open while Anchor GL-0010 pursues disposal through a specific licensee authorized to perform this sort of activity/retrieval.
"Reporting Requirement: Arkansas State Board of Health Rules for Control of Sources of Ionizing Radiation RH-402.c.5. and 10 CFR Part 31.5(c)(5)."
State Event Report ID No.: AR-2022-04
* * * UPDATE ON 3/22/2022 AT 1534 EDT FROM CHRISTY STEWARD TO BRIAN LIN * * *
"On March 17, 2022, WW Recycling in Marmaduke, Arkansas, contacted the Arkansas Department of Health - Radiation Control Section to report the discovery of a second gauge. Photos received March 18, 2022, confirm this gauge to be similar to the generally licensed fixed gauge discovered then reported to the Department on March 2, 2022 (NDC model 103X, SN 13629, Am-241, 5.55 GBq). SN 13629 was once registered to Anchor Packaging Company in Paragould, Arkansas, and later documented as disposed. The gauge was found in the remnants of the original load where the first gauge was found. The gauge was placed into a radioactive material - labeled small drum and secured in the remote storage building where the initial gauge is being stored (also in a small drum).
"WW Recycling personnel measured 40 microR/hr, via their Ludlum 193-6, on contact with the outside of the wall closest to the two drums. Inside the building, about 7 feet away from the drums, radiation levels begin increasing above background. The photo indicates the shutter to be attached but not closed. There are no known exposures.
"Reporting requirements: Arkansas State Board of Health Rules for Control of Sources of Ionizing Radiation - RH-1501.a.1.A. and RH-1501.b. pursuant to RH-409.c.10. "
Notified R4DO (Taylor), and NMSS Events Notification via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf.
Power Reactor
Event Number: 55800
Facility: Oconee
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: Chris McDuffie
HQ OPS Officer: Thomas Kendzia
Region: 2 State: SC
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP
NRC Notified By: Chris McDuffie
HQ OPS Officer: Thomas Kendzia
Notification Date: 03/23/2022
Notification Time: 16:43 [ET]
Event Date: 02/13/2022
Event Time: 16:25 [EST]
Last Update Date: 03/23/2022
Notification Time: 16:43 [ET]
Event Date: 02/13/2022
Event Time: 16:25 [EST]
Last Update Date: 03/23/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Miller, Mark (R2DO)
Miller, Mark (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Hot Standby | 0 | Hot Standby |
EMERGENCY FEEDWATER SYSTEM ACTUATION
The following information was provided by the licensee via email and phone:
"At 1625 [EST] on 2/13/2022, with Unit 2 in Mode 3 at 0 percent power and plant heat up to normal operating temperature in progress, an actuation of the Emergency Feedwater System (EFW) occurred. The reason for the EFW auto-start was lowering water level in the 2A and 2B Steam Generators due to failure of the 2A Main Feedwater Pump to respond as required to maintain Steam Generator water level as Steam Generator pressure increased during plant heat up. The 2A and 2B Motor Driven Emergency Feedwater (MDEFW) pumps automatically started as designed when the 'low steam generator level' signal was received for the 2A and 2B Steam Generators.
"Following further evaluation, it was determined that a valid EFW actuation occurred, therefore this event is being reported as a late 8-hour non-emergency notification of a valid actuation of the EFW system in accordance with 10 CFR 50.72(b)(3)(iv)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."
The following information was provided by the licensee via email and phone:
"At 1625 [EST] on 2/13/2022, with Unit 2 in Mode 3 at 0 percent power and plant heat up to normal operating temperature in progress, an actuation of the Emergency Feedwater System (EFW) occurred. The reason for the EFW auto-start was lowering water level in the 2A and 2B Steam Generators due to failure of the 2A Main Feedwater Pump to respond as required to maintain Steam Generator water level as Steam Generator pressure increased during plant heat up. The 2A and 2B Motor Driven Emergency Feedwater (MDEFW) pumps automatically started as designed when the 'low steam generator level' signal was received for the 2A and 2B Steam Generators.
"Following further evaluation, it was determined that a valid EFW actuation occurred, therefore this event is being reported as a late 8-hour non-emergency notification of a valid actuation of the EFW system in accordance with 10 CFR 50.72(b)(3)(iv)(A).
"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."