Event Notification Report for August 29, 2021

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/28/2021 - 08/29/2021

EVENT NUMBERS
5543555436
Power Reactor
Event Number: 55435
Facility: Waterford
Region: 4     State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: Samantha Smith
HQ OPS Officer: Ossy Font
Notification Date: 08/29/2021
Notification Time: 19:49 [ET]
Event Date: 08/29/2021
Event Time: 18:12 [CDT]
Last Update Date: 09/01/2021
Emergency Class: Unusual Event
10 CFR Section:
50.72(a) (1) (i) - Emergency Declared
Person (Organization):
KOZAL, JASON (R4)
MORRIS, SCOTT (R4)
VEIL, ANDREA (HQ)
GRANT, JEFFERY (IR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
EN Revision Imported Date: 9/30/2021

EN Revision Text: NOTIFICATION OF UNUSUAL EVENT DUE TO LOSS OF OFFSITE POWER

Waterford 3 shut down the reactor in preparation for Hurricane Ida landfall prior to this event.

At 1812 CDT, Waterford 3 declared a notification of unusual event under EAL S.U. 1.1 due to a loss of offsite power as a result of hurricane Ida. Plant power is being provided via emergency diesel generators. The NRC Activated at 2016 EDT with Region IV in the lead.

Notified DHS SWO, DOE Ops Center, FEMA Ops Center, HHS Ops Center, CISA Central, USDA Ops Center, EPA Emergency Ops Center, DHS Nuclear SSA (email), FEMA NWC (email), and FEMA NRCC SASC (email).

* * * UPDATE ON 9/1/21 AT 0132 EDT FROM ALEX SANDOVAL TO BRIAN P. SMITH * * *

At 2345 CDT on 8/31/21, Waterford 3 terminated their notification of unusual event under EAL S.U. 1.1. Offsite power has been restored to both safety-related electrical buses. The NRC remains Activated with Region IV in the lead while reviewing additional criteria to exit Activation.

Notified DHS SWO, DOE Ops Center, FEMA Ops Center, HHS Ops Center, CISA Central, USDA Ops Center, EPA Emergency Ops Center, DHS Nuclear SSA (email), FEMA NWC (email), and FEMA NRCC SASC (email), R4DO (Josey), IR MOC (Kennedy), NRR EO (Miller), R4 (Lantz).


Power Reactor
Event Number: 55436
Facility: Waterford
Region: 4     State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: John Lewis
HQ OPS Officer: Bethany Cecere
Notification Date: 08/30/2021
Notification Time: 01:50 [ET]
Event Date: 08/29/2021
Event Time: 18:04 [CDT]
Last Update Date: 10/25/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation 50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
KOZAL, JASON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Hot Shutdown 0 Cold Shutdown
Event Text
EN Revision Imported Date: 11/24/2021

EN Revision Text: SAFETY SYSTEM ACTUATION

"At 1804 CDT on 8/29/2021, Waterford 3 Steam Electric Station (WF3) experienced a Loss of Off Site Power event due to Hurricane Ida (See EN #55435). This event caused an automatic actuation of Emergency Diesel Generators Trains A and B. Both Emergency Diesel Generators started as designed and both are currently operating normally supplying power to their respective Class 1E Safety Busses. This automatic actuation is reportable in accordance with 10 CFR 50.72(b)(3)(iv)(A). Prior to the loss of offsite power, WF3 was in progress of performing a plant cooldown in accordance with procedural guidance. As part of this cooldown and after entering Mode 4, all Safety Injection Tanks were isolated. As a result of losing offsite power, Reactor Coolant System Temperature increased above 350F which is above the temperature requirements for Mode 4. Safety Injection Tanks are required to be unisolated and OPERABLE in Mode 3. Therefore, with no Safety Injection Tanks OPERABLE, this constituted an event or condition that could have prevented the fulfillment of a safety function and the unit entered Technical Specification 3.0.3. The unit was in Technical Specification 3.0.3 for approximately 43 minutes from 1805 CDT until 1848 CDT when Mode 4 conditions were re-established. This event or condition that could have prevented the fulfillment of a Safety Function is reportable in accordance with 10 CFR 50.72(b)(3)(v)(D).

"While continuing to perform the Reactor Coolant System Cooldown and prior to placing Shutdown Cooling Train in service, it became necessary to start one train of Emergency Feedwater. Emergency Feedwater Train A was manually started at 1847 CDT to feed the Steam Generators and was secured at 1947 CDT. Emergency Feedwater Train A started and operated normally during this period. This manual actuation is reportable in accordance with 10 CFR 50.72(b)(3)(iv)(A)."

The licensee notified the NRC Resident Inspector.

* * * UPDATE AT 1549 EDT ON OCTOBER 25, 2021 FROM CHANTEL HATTAWAY TO BRIAN P. SMITH * * *

"The purpose of this notification is to revise Event Notification Report (EN) 55436 to include a partial retraction. On August 29, 2021, Waterford Steam Electric Station, Unit 3 (WF3) experienced a loss of offsite power (LOOP) event due to Hurricane Ida. Prior to the LOOP, WF3 had shutdown to Mode 3 (Hot Standby) in anticipation of the LOOP and was performing a plant cooldown in accordance with procedural guidance. When Mode 4 (Hot Shutdown) was achieved, all Safety Injection Tanks (SITs) were isolated as part of the plant cooldown. After the LOOP, Reactor Coolant System (RCS) temperature increased and the Core Exit Thermocouples (CETs) indicated that RCS temperature had exceeded 350 degrees F. Based on the CETs, this was above the temperature requirements for Mode 4 and, as such, WF3 declared entry into Mode 3. The SITs are required to be unisolated and Operable in Mode 3. Since no SITs were Operable at that time, it was determined that this constituted an event or condition that could have prevented the fulfillment of a safety function and included this as part of the EN 55436 report in accordance with 10 CFR 50.72(b)(3)(v)(D).

"An engineering evaluation has subsequently been performed to validate whether the RCS temperature excursion following the LOOP actually reached 350 degrees F. As defined in WF3 Technical Specification (TS) Table 1.2, Operational Mode temperatures are a function of RCS average temperature (Tavg), not just the indicated temperature of the CETs. Based on the calculated Tavg using validated temperatures, it was concluded that 350 degrees F was not reached. Thus, WF3 remained in Mode 4 following the LOOP and there was no event or condition that could have prevented the fulfillment of a safety function that was reportable pursuant to 10 CFR 50.72(b)(3)(v)(D).

"The remainder of EN 55436 remains correct and unchanged."

The licensee notified the NRC Resident Inspector.

Notified R4DO (Pick)