Event Notification Report for March 22, 2021

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/19/2021 - 03/22/2021

EVENT NUMBERS
55133 55135 55136 55146
Agreement State
Event Number: 55133
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: EPIC Piping, LLC
Region: 4
City: Livingston   State: LA
County:
License #: LA-13463-L01, Amendment 10, AI# 203655
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Thomas Herrity
Notification Date: 03/11/2021
Notification Time: 13:50 [ET]
Event Date: 03/11/2021
Event Time: 00:00 [CST]
Last Update Date: 03/11/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
JEFFREY JOSEY (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - OVEREXPOSED WORKER

The following was received from the State of Louisiana via email:

"EPIC Piping, LLC contacted the Louisiana Department of Environmental Quality (LDEQ), Emergency and Radiological Services Division (ERSD), Radiation Section about a Landauer Badge Report indicating an exposure (real or threatened) greater than or equal to 5 Rem. The badge indicated a 7,232 mR exposure. The Landauer Badge Report covered dates of January 15 to February 15, 2021. The source was an Ir-192 using a QSA Global 880D industrial radiography camera. The facility uses permanent industrial radiography shooting cells. The radiographer used potentially different radiography cameras having different sources according to which shooting cell was being used that day."

Louisiana Event Report ID Number: LA 20210004


Agreement State
Event Number: 55135
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: Globe X-Ray Services, Inc.
Region: 4
City: Tulsa   State: OK
County:
License #: OK-15194-02
Agreement: Y
Docket:
NRC Notified By: Libby McCaskill
HQ OPS Officer: Thomas Herrity
Notification Date: 03/12/2021
Notification Time: 11:29 [ET]
Event Date: 03/11/2021
Event Time: 00:00 [CST]
Last Update Date: 03/15/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
JEFFREY JOSEY (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
EN Revision Imported Date: 3/16/2021

EN Revision Text: AGREEMENT STATE REPORT - OVEREXPOSED WORKER

The following was reported by the state of Oklahoma via email:

"Globe X-ray Services, Inc., a radiography company, reported via phone this morning that a technician's dosimeter received a 5.3 rem dose. The dose was reported on the January dosimetry report and the licensee learned about it yesterday.

"The licensee is currently working with Landauer [badge supplier] to have the badge processed further, and is investigating the exposure.

"No additional information is known at this time, we will provide updates as additional information becomes available."

Oklahoma event Number: Not Assigned

* * * UPDATE ON MARCH 15, 2021, FROM ELIZABETH McCASKILL TO THOMAS HERRITY * * *

The following update was received form the state of Oklahoma via email:

"The badge reading was: 5132 mrem DDE, 5192 mrem LDE and 5192 mrem SDE.

"The RSO stated that they believe the Landauer dosimeter received the dose on January 22, 2021.

"The RSO interviewed the radiographer and it is believed that the Landauer dosimeter was in a jacket pocket in the shooting area during exposures.

"The alarming ratemeter and pocket dosimeter readings were not elevated for January 22, 2021.

"The licensee has contacted Landauer and are awaiting imaging results to determine if the exposure was static."

Notified R4DO (Kellar), and NMSS Events Notification via email.


Agreement State
Event Number: 55136
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: University of Florida
Region: 1
City: Jacksonville   State: FL
County:
License #: 0031-3
Agreement: Y
Docket:
NRC Notified By: Matthew Senison
HQ OPS Officer: Kerby Scales
Notification Date: 03/12/2021
Notification Time: 16:49 [ET]
Event Date: 03/12/2021
Event Time: 09:48 [EST]
Last Update Date: 03/12/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
GRAY, MEL (R1)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
Event Text
AGREEMENT STATE REPORT - PRESCRIBED UNDERDOSE

The following is a summary of an email from the state of Florida:

At 1600 [EST], the [Radiation Safety Officer] RSO called to report a radiation underdose. Following the procedure, the waste was collected and measured to calculate the actual activity delivered. The actual activity delivered was 0.76 GBq, 90 percent of the prescribed treatment dose. Post procedure, during the room survey, inside the Plexiglas Administration Box a high level of activity was detected. The box was placed in double bags and relocated to the waste storage area. An investigation into the event is ongoing to calculate the activity in the box following administration. No individuals were contaminated and there was no harm to the patient.

Florida Incident Number: FL21-038

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 55146
Facility: Quad Cities
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: Mike MacLennon
HQ OPS Officer: Jeffrey Whited
Notification Date: 03/20/2021
Notification Time: 04:55 [ET]
Event Date: 03/19/2021
Event Time: 20:30 [CDT]
Last Update Date: 03/20/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
HANNA, JOHN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
AUTOMATIC ACTUATION OF UNIT 1 EMERGENCY DIESEL GENERATOR

"At 20:30 CDT on March 19, 2021, with the Unit 1 in Mode 5 at 0 percent power, an actuation of the Unit 1 Emergency Diesel Generator (EDG) occurred during outage activities on Transformer 12 (T-12) resulting in a trip. The cause of the Unit 1 EDG auto-start was bus undervoltage as a result of the T-12 trip. The Unit 1 EDG automatically started as designed when the Bus 14-1 undervoltage signal was received.

"This event is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the Unit 1 EDG.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."