Event Notification Report for May 26, 2020
|
U.S. Nuclear Regulatory Commission Event Reports For ** EVENT NUMBERS ** |
| 54715 | 54725 | 54726 | 54727 |
| Agreement State | Event Number: 54715 |
| Rep Org: ALABAMA RADIATION CONTROL Licensee: Indorama Ventures Xylenes and PTA, LLC Region: 1 City: State: AL County: License #: 256 Agreement: Y Docket: NRC Notified By: Cason Coan HQ OPS Officer: Andrew Waugh |
Notification Date: 05/15/2020 Notification Time: 09:38 [ET] Event Date: 05/14/2020 Event Time: 00:00 [CDT] Last Update Date: 05/15/2020 |
| Emergency Class: Non Emergency 10 CFR Section: Agreement State |
Person (Organization): CHRISTOPHER LALLY (R1DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - BROKEN SHUTTER HANDLE The following information was received via email: "The Alabama Dept. of Public Health Office of Radiation Control was notified on May 14, 2020, by a representative of Indorama Ventures Xylenes and PTA, LLC of a broken shutter handle on a fixed gauge. The licensee identified the device as an Ohmart SHRD-1-35, s/n 0018HB, with a Co-60 source of 3000 mCi, manufactured 10/2000. The licensee stated that there were no exposures to individuals as a result of this shutter failure, apparently no radioactive material was released outside the source housing. The device and source are in storage onsite, waiting for disposal." Alabama Incident Report No.: 20-08 |
| Power Reactor | Event Number: 54725 |
| Facility: Grand Gulf Region: 4 State: MS Unit: [1] [] [] RX Type: [1] GE-6 NRC Notified By: Leroy Purdy HQ OPS Officer: Bethany Cecere |
Notification Date: 05/25/2020 Notification Time: 08:44 [ET] Event Date: 05/25/2020 Event Time: 04:33 [CDT] Last Update Date: 05/25/2020 |
| Emergency Class: Non Emergency 10 CFR Section: 50.72(b)(2)(iv)(B) - RPS Actuation - Critical |
Person (Organization): RYAN ALEXANDER (R4DO) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 1 | A/R | Y | 66 | Power Operation | 0 | Hot Shutdown |
Event Text
| AUTOMATIC REACTOR SCRAM DUE TO MAIN TURBINE TRIP "An [automatic] reactor SCRAM occurred at 0433 CDT, on 05/25/2020, from 66 percent core thermal power. The cause of the SCRAM was due to a Main Turbine Trip. The cause of the Turbine Trip is under investigation. "All systems responded as designed. No loss of offsite power or [Emergency Safety Feature] (ESF) power occurred. No [Emergency Core Cooling System] (ECCS) or Emergency Diesel Generator initiations occurred. Main Steam Isolation valves remained open and no radioactive release occurred due to this event. The plant is stable in mode 3. This event is being reported under 10 CFR 50.72(b)(2)(iv)(B), as any event or condition that results in actuation of the Reactor Protection System (RPS), when the reactor is critical. "The NRC Resident Inspector has been notified." Decay heat removal is through the Feedwater and Condensate System. |
| Power Reactor | Event Number: 54726 |
| Facility: Fermi Region: 3 State: MI Unit: [2] [] [] RX Type: [2] GE-4 NRC Notified By: Kelley Belenky HQ OPS Officer: Jeffrey Whited |
Notification Date: 05/26/2020 Notification Time: 13:17 [ET] Event Date: 05/26/2020 Event Time: 10:04 [EDT] Last Update Date: 05/26/2020 |
| Emergency Class: Non Emergency 10 CFR Section: 26.719 - Fitness For Duty |
Person (Organization): LAURA KOZAK (R3DO) FFD GROUP (EMAIL) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 2 | N | N | 0 | Defueled | 0 | Defueled |
Event Text
| FITNESS FOR DUTY (FFD) POSITIVE TEST A non-licensed employee supervisor had a confirmed positive for alcohol during a follow-up fitness-for-duty test. The employee's access to the plant has been terminated. The licensee notified the NRC Resident Inspector. |
| Power Reactor | Event Number: 54727 |
| Facility: Surry Region: 2 State: VA Unit: [1] [2] [] RX Type: [1] W-3-LP,[2] W-3-LP NRC Notified By: Alan Bialowas HQ OPS Officer: Jeffrey Whited |
Notification Date: 05/26/2020 Notification Time: 15:55 [ET] Event Date: 05/25/2020 Event Time: 19:38 [EDT] Last Update Date: 05/26/2020 |
| Emergency Class: Non Emergency 10 CFR Section: 26.719 - Fitness For Duty |
Person (Organization): MARK MILLER (R2DO) FFD GROUP (EMAIL) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation | |||||||
| 2 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
Event Text
| FITNESS FOR DUTY (FFD) POSITIVE TEST A contract foreman had a confirmed positive for alcohol during a random fitness-for-duty test. The employee's access to the plant has been terminated. The licensee notified the NRC Resident Inspector. |