Event Notification Report for January 24, 2020
|
U.S. Nuclear Regulatory Commission Event Reports For ** EVENT NUMBERS ** |
| 54465 | 54479 | 54481 | 54482 |
| !!!!! THIS EVENT HAS BEEN RETRACTED.THIS EVENT HAS BEEN RETRACTED !!!!! | |
| Power Reactor | Event Number: 54465 |
| Facility: OCONEE Region: 2 State: SC Unit: [1] [2] [3] RX Type: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-LP NRC Notified By: CHRIS JUDD HQ OPS Officer: BRIAN LIN |
Notification Date: 01/07/2020 Notification Time: 19:09 [ET] Event Date: 01/07/2020 Event Time: 13:41 [EST] Last Update Date: 01/23/2020 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION |
Person (Organization): STEVEN RUDISAIL (R2DO) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation | |||||||
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation | |||||||
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
Event Text
| CHILL WATER SYSTEM INOPERABLE "At 1341[EST], on 01/07/20, it was discovered all trains of the Chilled Water System were simultaneously Inoperable; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v)(D). During this event, the Bravo train chiller was operating in a maintenance run and the temporary chiller was available and placed in service promptly to restore the safety function. "The control room area cooling safety function was restored at time 1435 [EST] when one required train was declared Operable. There was no impact on the health and safety of the public or plant personnel. "The NRC Resident Inspector has been notified." * * * RETRACTION ON 1/23/2020 AT 1718 EST FROM JERRY COLLIER TO THOMAS KENDZIA * * * "The purpose of this notification is to retract a previous report made on January 7, 2020, at 1909 EST (EN#54465). A subsequent evaluation determined that the Bravo train chiller, which was running at the time of the event, would be able to perform its safety function and was operable at the time of the event. Therefore, there was no loss of safety function. "The NRC Senior Resident Inspector has been notified." Notified R2DO (Coovert). |
| Agreement State | Event Number: 54479 |
| Rep Org: OHIO BUREAU OF RADIATION PROTECTION Licensee: COLUMBUS AUTO SHREDDING Region: 3 City: COLUMBUS State: OH County: License #: Agreement: Y Docket: NRC Notified By: MICHAEL SNEE HQ OPS Officer: DONALD NORWOOD |
Notification Date: 01/15/2020 Notification Time: 11:42 [ET] Event Date: 01/14/2020 Event Time: 00:00 [EST] Last Update Date: 01/15/2020 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE |
Person (Organization): ERIC DUNCAN (R3DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - Cs-137 SOURCE FOUND AT A SCRAP YARD The following information was received via E-mail: "An unknown device was discovered at a metal scrap yard in Ohio. The device has no markings or labels. A Cs-137 source of unknown activity was identified in the device. No loose contamination was detected. Maximum dose rate on the device is 500 mr/hr and 6 mr/hr at one meter. The device is secure at the facility pending disposal. The Ohio Department of Health will continue to track down the origin of the source." Ohio Item Number: OH200001 |
| Agreement State | Event Number: 54481 |
| Rep Org: LOUISIANA RADIATION PROTECTION DIV Licensee: DOW CHEMICAL COMPANY Region: 4 City: PLAQUEMINE State: LA County: License #: LA-2002-L02 Agreement: Y Docket: NRC Notified By: JAMES PATE HQ OPS Officer: DONALD NORWOOD |
Notification Date: 01/15/2020 Notification Time: 16:16 [ET] Event Date: 01/15/2020 Event Time: 00:00 [CST] Last Update Date: 01/15/2020 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE |
Person (Organization): CALE YOUNG (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - STUCK PROCESS GAUGE SHUTTER The following information was received via E-mail: "On January 15, 2020, at 1400 CST, the DOW Chemical Radiation Safety Officer contacted the supervisor of the Louisiana Department of Environmental Quality/ERSD/Radiation Section to report that a shutter failed to shut during routine maintenance. The shutter which failed to shut was found on January 14, 2020, at approximately 1500 CST, at DOW Chemicals Company. The shutter is stuck in the open condition and does not effect operation. The gauge is a Vega Americas model number SHF2B, s/n 38953125, with a 500 mCi Cs-137 sealed source, s/n 0368CR. The licensee has contacted the contractor for repair and is awaiting a date and time for the repair." Event Report ID No.: LA20200001 |
| Agreement State | Event Number: 54482 |
| Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES Licensee: IRISNDT INC Region: 4 City: HOUSTON State: TX County: License #: L06435 Agreement: Y Docket: NRC Notified By: MATTHEW KENNINGTON HQ OPS Officer: OSSY FONT |
Notification Date: 01/16/2020 Notification Time: 14:47 [ET] Event Date: 01/15/2020 Event Time: 00:00 [CST] Last Update Date: 01/16/2020 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE |
Person (Organization): CALE YOUNG (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA SOURCE DISCONNECT The following was received from the Texas Department of State Health Services (the Agency) via email: "On January 16, 2020, the Agency was notified by a licensee of a source disconnect event. The licensee stated that on January 15, 2020, a crew using a QSA Spec-150 camera with 76 Curies of iridium-192 were unable to retract the source back into the camera. The source was recovered and returned to the shielded position. The licensee suspects that the source was not properly connected to the drive cable, allowing the source to be pushed inside the guide tube but unable to retract it. The licensee stated that the individuals that performed the recovery received 50 mR to 60 mR of exposure, and that no overexposures are suspected as a result of the event. Investigation is ongoing. Additional information will be provided as it is received in accordance with SA-300." Texas Incident #: 9732 |
Page Last Reviewed/Updated Wednesday, March 24, 2021