Agreement State Event Number: 54468
Rep Org: VT DEPARTMENT OF HEALTH
Licensee: UNIVERSITY OF VERMONT MEDICAL CENTER
Region: 1
City:   State: VT
County:
License #:
Agreement: Y
Docket:
NRC Notified By: FRANCIS O'NEILL
HQ OPS Officer: MICHAEL BLOODGOOD
Notification Date: 01/09/2020
Notification Time: 07:33 [ET]
Event Date: 11/27/2019
Event Time: 00:00 [EST]
Last Update Date: 01/09/2020
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
DAN SCHROEDER (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
This material event contains a "Less than Cat 3" level of radioactive material.

Event Text

AGREEMENT STATE REPORT - IODINE-125 PROSTATE IMPLANT SEED

The following is a synopsis of a report from the Vermont (VT) Department of Health (the Department):

On November 27, 2019, a prostate seed implant (PSI) procedure using Iodine-125 (I-125) seeds was performed. During the latter part of the procedure, while loading one last, extra needle for the radiation oncologist (the Authorized User), the authorized medical physicist (AMP) lost control of one I-125 seed.

A number of surveys were conducted immediately following the loss of the seed, producing only background readings.

On December 4, 2019, a Department Senior Radiological Health Specialist conducted a follow-up survey in the PSI procedure room and waste storage areas. The lost seed was not located.

As a corrective action, the licensee may consider ordering additional seeds in the form of preloaded needles to avoid handling individual prostate seeds.

The lost prostate seed is believed to have fallen into the bore of the implanting needle and was subsequently implanted into the prostate. This is not believed to have any clinical significance on the resulting absorbed dose to the prostate, urethra, or rectum. The patient had 76 prostate seeds planned to be implanted and a single extra seed would result in approximately 1 percent additional absorbed dose to the treatment volume.

As verification, a post-implant treatment plan was calculated with an extra prostate seed placed near the location of the last needle within the treatment volume. The resulting dose metrics confirmed that absorbed doses increased by about 1 percent.

The potential radiation exposure to an individual that is continuously present near the lost seed was evaluated and determined to be less than the 0.1 rem annual public exposure limit.

No personnel contamination occurred as a result of this event.

VT Incident Number: VT19-002

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

Agreement State Event Number: 54469
Rep Org: MISSISSIPPI DIV OF RAD HEALTH
Licensee: ALS INDUSTRIAL PTY
Region: 4
City: VICKSBURG   State: MS
County:
License #: LA-13553-L01
Agreement: Y
Docket:
NRC Notified By: JAYSON MOAK
HQ OPS Officer: KARL DIEDERICH
Notification Date: 01/09/2020
Notification Time: 12:50 [ET]
Event Date: 12/30/2019
Event Time: 00:00 [CST]
Last Update Date: 01/09/2020
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
HEATHER GEPFORD (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)

Event Text

AGREEMENT STATE REPORT - RADIOGRAPHY SOURCE COULDN'T BE RETRACTED

The following was received from the Agreement State via e-mail:

"RSO reported inability to retract a 40.2 Ci Ir-192 source (Source Model A424-9), (Source Serial No. 89706G) into the Sentinel/QSA 880 Delta exposure device (Serial No. D12297) during the period of 12/31/2019 to 1/1/2020.

"Licensee notified of 24 hour reporting requirement and to send written 30-day report."

Mississippi report number: MS-200001.