Event Notification Report for January 01, 2020
|
U.S. Nuclear Regulatory Commission Operations Center Event Reports For ** EVENT NUMBERS ** |
| 54455 | 54456 |
| Agreement State | Event Number: 54455 |
| Rep Org: FLORIDA BUREAU OF RADIATION CONTROL Licensee: UF HEALTH SHANDS CANCER HOSPITAL Region: 1 City: GAINESVILLE State: FL County: License #: 0031-3 Agreement: Y Docket: NRC Notified By: DAVID PIESKI HQ OPS Officer: BRIAN LIN |
Notification Date: 12/23/2019 Notification Time: 13:49 [ET] Event Date: 12/20/2019 Event Time: 00:00 [EST] Last Update Date: 12/23/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE |
Person (Organization): JOHN CHERUBINI (R1DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - PATIENT UNDERDOSE The following is a synopsis of an email from the state of Florida: On December 20th, 2019, a patient was prescribed and administered a yttrium-90 treatment. The patient received 25 percent of the prescribed dose as reported by the Radiation Safety Officer (RSO) to the Florida Bureau of Radiation Control on December 23. Further details, including actual prescription amounts, are awaiting a submitted report by the hospital's Interventional Radiology Department. FL Incident Number: FL19-154 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. |
| Agreement State | Event Number: 54456 |
| Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES Licensee: INTERNATIONAL PAPER COMPANY Region: 4 City: ORANGE State: TX County: License #: L06932 Agreement: Y Docket: NRC Notified By: KAREN BLANCHARD HQ OPS Officer: BETHANY CECERE |
Notification Date: 12/23/2019 Notification Time: 14:19 [ET] Event Date: 12/20/2019 Event Time: 00:00 [CST] Last Update Date: 12/23/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE |
Person (Organization): JAMES DRAKE (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - THREE GAUGE SHUTTERS INOPERABLE The following was received via email from the state of Texas: "On December 23, 2019, the licensee notified the Agency [Texas Department of State Health Services] that late, after hours, on December 20, 2019, it had discovered during routine gauge inspections that the shutters on three (3) of their Berthold Model LB 7440 gauges were inoperable. The shutters are in the open position which is the normal operating position for the gauges. Two of the gauges contain 100 milliCuries of cesium-137 each and the third contains 10 milliCuries of cesium-137. Due to their location, there is no increased risk of exposure to any persons. The licensee is in the process of scheduling repairs. An investigation into this event is ongoing. More information will be provided as it is obtained in accordance with SA-300." TX Incident # 9729 |