Event Notification Report for September 06, 2019
U.S. Nuclear Regulatory Commission Event Reports For ** EVENT NUMBERS ** |
| 54243 | 54245 | 54256 | 54257 |
| Agreement State | Event Number: 54243 |
| Rep Org: OR DEPT OF HEALTH RAD PROTECTION Licensee: Region: 4 City: HERMISTON State: OR County: License #: Agreement: Y Docket: NRC Notified By: DARYL LEON HQ OPS Officer: RICHARD SMITH | Notification Date: 08/28/2019 Notification Time: 16:35 [ET] Event Date: 08/28/2019 Event Time: 11:02 [PDT] Last Update Date: 08/28/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): RAY AZUA (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
| This material event contains a "Less than Cat 3" level of radioactive material. |
Event Text
| AGREEMENT STATE REPORT - MOISTURE DENSITY GAUGE FOUND IN SCRAP YARD The following is a summary of information received from the State of Oregon via phone call: On August 28, 2019, at 1102 PDT, the Oregon Department of Health and Radiation Protection received a report from the R.S. Davis Scrap Yard, that a moisture density gauge was found in a 55 gallon drum that was crimped at the top so the gauge will not fall out. The gauge is a CPN MC-3 Porta Probe with a 10 mCi Cs-137 source and a 50 mCi Am/Be 241 source. The scrap yard employed a contractor to take radiation readings and perform a swipe test of the gauge. The gauge housing appears to be damaged but the source housing seems intact. The contractor was unable to inspect the bottom of the gauge inside the drum. The following was measured: A reading of 13 mR/hr on contact at the side A reading of 200 mR/hr on contact at the bottom A reading of 3 mR/hr one foot from the side Swipe Test results were less than background The State of Oregon Radiation Inspector believes the gauge is damaged because normal radiation readings for a similar gauge at one meter would be 0.4 mR/hr. The State of Oregon will be conducting an investigation of this event. The gauge is currently under the control of the scrap yard. Oregon Event Reference Number: 19-0037. THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf |
| Agreement State | Event Number: 54245 |
| Rep Org: OK DEQ RAD MANAGEMENT Licensee: HOLLYFRONTIER TULSA REFINING Region: 4 City: TULSA State: OK County: TULSA License #: GLD0027 Agreement: Y Docket: NRC Notified By: KEVIN SAMPSON HQ OPS Officer: BRIAN LIN | Notification Date: 08/29/2019 Notification Time: 17:18 [ET] Event Date: 08/28/2019 Event Time: 00:00 [CDT] Last Update Date: 08/29/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): RAY AZUA (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| AGREEMENT STATE REPORT - SHUTTER FAILURE The following was received from the Oklahoma Department of Environmental Quality via email: "The State of Oklahoma reported that a generally-licensed Ronan Model SA-F37 fixed gauge (S/N M2265) containing 1.5 Ci of Cs-137 experienced a shutter failure during routine maintenance. The source holder is being removed from service and will be stored pending disposal." |
| Power Reactor | Event Number: 54256 |
| Facility: CATAWBA Region: 2 State: SC Unit: [1] [2] [] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: SCOTT MILTON HQ OPS Officer: JEFFREY WHITED | Notification Date: 09/05/2019 Notification Time: 16:53 [ET] Event Date: 04/28/2019 Event Time: 22:00 [EDT] Last Update Date: 09/05/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): SCOTT SHAEFFER (R2DO) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation | |||||||
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
Event Text
| TECHNICAL SUPPORT CENTER VENTILATION SYSTEM OUT OF SERVICE DUE TO DISCOVERED CONDITION "This is a non-emergency eight hour notification for a loss of Emergency Assessment Capability. "A condition impacting functionality due to a loss of cooling of the Technical Support Center (TSC) ventilation system occurred on 4/28/19. Filtration capability was not impacted by this condition. Maintenance subsequently repaired the condition and the TSC ventilation system was returned to service on 5/1/19. This condition did not affect the health and safety of the public or station employees. "The NRC Resident Inspector has been notified. "This event is reportable in accordance with 10 CFR 50.72(b)(3)(xiii) as the discovered condition affected the functionality of an emergency response facility." |
| Power Reactor | Event Number: 54257 |
| Facility: SOUTH TEXAS Region: 4 State: TX Unit: [] [2] [] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: MICHAEL CHANDLER HQ OPS Officer: CATY NOLAN | Notification Date: 09/06/2019 Notification Time: 02:47 [ET] Event Date: 09/05/2019 Event Time: 21:15 [CDT] Last Update Date: 09/06/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(ii)(B) - UNANALYZED CONDITION 50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION | Person (Organization): NEIL O'KEEFE (R4DO) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
Event Text
| CONTAINMENT PENETRATION DISCOVERED NOT ISOLATED "At 2115 CDT on 9/5/2019, an inside containment test connection and inoperable outside containment isolation valve were discovered to be open for a containment air sample penetration. This resulted in the containment penetration not being isolated. The inside containment test connection was closed at 2322 CDT on 9/5/2019. "This event is being reported under 10 CFR 50.72(b)(3)(v)(C) and (D) and 10 CFR 50.72(b)(3)(ii)(B). "There was no impact to the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified. " |