Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for February 14, 2019

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
2/13/2019 - 2/14/2019

** EVENT NUMBERS **

 

53862 53870

Agreement State Event Number: 53862
Rep Org: ILLINOIS EMERGENCY MGMT. AGENCY
Licensee: RIVERSIDE MEDICAL CENTER
Region: 3
City: KANKAKEE   State: IL
County:
License #: IL-01242-01
Agreement: Y
Docket:
NRC Notified By: GARY FORSEE
HQ OPS Officer: JEFFREY WHITED
Notification Date: 02/06/2019
Notification Time: 11:40 [ET]
Event Date: 04/20/2016
Event Time: 00:00 [CST]
Last Update Date: 02/06/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
ROBERT DALEY (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)

Event Text

AGREEMENT STATE REPORT - UNDERDOSE EXCEEDING 20 PERCENT OF THE PRESCRIBED DOSE

The following was received via email from the state of Illinois:

"During a routine inspection [by the State of Illinois] of Riverside Medical Center, IL-01242-01, conducted on January 29, and continued document review conducted February 5, 2019, inspectors identified an apparent under dose to a patient receiving I-125 seed prostate therapy. The event occurred in April of 2016. Of the six patient records reviewed (all 2016), one post operational dosimetry report indicated a D90 of 120.7 Gy, resulting in a 24.5 percent variance from the prescribed dose of 160 Gy. Two of the patient records did not have a post operational dosimetry report and inspection findings indicate the licensee does not have written procedures for prostate seed therapies which ensure the administrations are in accordance with the written directive. As a result of the lack of procedures, the determination of a 20 percent variation from the prescribed dose is being compared against the D90 value following prior recorded NMED [Nuclear Materials Events Database] events and NRC guidance. The licensee has been notified and will submit a written report within 15 days.

"The licensee is not actively engaged in brachytherapy and the authorized user is no longer with the licensee. Agency enforcement action will ensure either procedures are established or modality authorization is removed. Pending appropriate address of the patient's treatment and root cause by the licensee, a reactive inspection is not being conducted in accordance with Management Directive 8.10, Section III(A)(3). This report will be updated as additional details become available."

Item Number: IL190007

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.

Power Reactor Event Number: 53870
Facility: GRAND GULF
Region: 4     State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: BILLY NEWMAN
HQ OPS Officer: JEFF HERRERA
Notification Date: 02/13/2019
Notification Time: 09:42 [ET]
Event Date: 02/12/2019
Event Time: 09:00 [CST]
Last Update Date: 02/13/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
VINCENT GADDY (R4DO)
FFD GROUP (EMAIL)
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation

Event Text

FITNESS FOR DUTY - ENTERGY NON LICENSED SUPERVISOR FAILED TO REPORT FOR FITNESS FOR DUTY TEST

On 1/17/2019 at 0619 CST, a non-licensed employee supervisor failed to report to perform a fitness for duty test. The individual's access to the site was terminated.

The NRC Resident Inspector will be notified.

Page Last Reviewed/Updated Thursday, August 27, 2026

Page Last Reviewed/Updated Thursday, August 27, 2026