Event Notification Report for February 07, 2019
|
U.S. Nuclear Regulatory Commission Event Reports For ** EVENT NUMBERS ** |
| 53850 | 53861 | 53863 |
| Non-Agreement State | Event Number: 53850 |
| Rep Org: INTERTEK ASSET INTEGRITY MANAGEMENT Licensee: INTERTEK ASSET INTEGRITY MANAGEMENT Region: 4 City: HOUMA State: LA County: License #: 17-29308-01 Agreement: Y Docket: NRC Notified By: WILLIAM JOHNSTON HQ OPS Officer: HOWIE CROUCH |
Notification Date: 01/29/2019 Notification Time: 10:44 [ET] Event Date: 01/29/2019 Event Time: 00:00 [CST] Last Update Date: 01/29/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 30.50(b)(2) - SAFETY EQUIPMENT FAILURE |
Person (Organization): GREG WERNER (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| RADIOGRAPHY CAMERA SOURCE DISCONNECTED The following incident occurred in federal waters on Chevron's St. Malo platform. On January 26, 2019, while retracting the source after a radiography shot, the radiographer determined that the source had become disconnected. The radiographer and assistant radiographer established a 2 mR boundary and contacted their radiation safety officer (RSO). The RSO dispatched a licensed source retriever to the platform. After arriving at the platform on January 27, 2019, the source retriever was able to place the source into a shielded container. The source and camera were transported back to the licensee facility located in Houma, LA. The camera and source will be inspected/repaired by the manufacturer prior to placing them back into service. The camera is a SPEC-150 camera, serial number 1717, containing a 33 Ci Ir-192 source, serial number ZI0603. The licensed retriever received 275 mR during the retrieval. The radiography and assistant radiography technicians received 24 mR and 41 mR exposure. |
| Power Reactor | Event Number: 53861 |
| Facility: QUAD CITIES Region: 3 State: IL Unit: [1] [] [] RX Type: [1] GE-3,[2] GE-3 NRC Notified By: DEREK DROCKELMAN HQ OPS Officer: JEFFREY WHITED |
Notification Date: 02/06/2019 Notification Time: 02:22 [ET] Event Date: 02/05/2019 Event Time: 18:04 [CST] Last Update Date: 02/06/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION |
Person (Organization): ROBERT DALEY (R3DO) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
Event Text
| UNIT ONE HPCI SYSTEM INOPERABLE DUE TO BLOWN FUSE "On February 5, 2019, at 1804 [CST], during a Unit 1 High Pressure Coolant Injection (HPCI) operability surveillance, a fuse blew in the logic for the motor speed changer for the turbine. The Unit 1 HPCI system was taken out of service for planned maintenance earlier in the day. The fuse issue was not related to any maintenance activities. Had HPCI been demanded, this fuse failure would not have allowed HPCI to reach its required speed. HPCI remains inoperable pending resolution of the issue. The Reactor Core Isolation Cooling (RCIC) system was confirmed operable. There were no other systems inoperable at the time of the event. HPCI had been last successfully tested on November 6, 2018. "This event is being reported as a condition that could have prevented fulfillment of a safety function in accordance with 10 CFR 50.72(b)(3)(v)(D). The HPCI system is a single train system and the loss of HPCI could impact the plant's ability to mitigate the consequences of an accident. "The NRC Senior Resident Inspector has been notified." Inoperable HPCI places the unit in a 14 day Technical Specification Limiting Condition of Operability. |
| Power Reactor | Event Number: 53863 |
| Facility: INDIAN POINT Region: 1 State: NY Unit: [2] [3] [] RX Type: [2] W-4-LP,[3] W-4-LP NRC Notified By: TERRY R. JONES HQ OPS Officer: BETHANY CECERE |
Notification Date: 02/06/2019 Notification Time: 12:46 [ET] Event Date: 02/05/2019 Event Time: 18:00 [EST] Last Update Date: 02/06/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 26.719 - FITNESS FOR DUTY |
Person (Organization): CHRISTOPHER CAHILL (R1DO) FFD GROUP (EMAIL) |
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | |||||||
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation | |||||||
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
Event Text
| FITNESS-FOR-DUTY - CONTRABAND DISCOVERED IN PROTECTED AREA On February 05, 2019 at approximately 1800 EST, candy that contained alcohol was discovered in the plant protected area. The candy was removed from the protected area by station security management. The licensee notified the NRC Resident Inspector and the State of New York Public Service Commission. |