| Rep Org: BAXTER Licensee: BAXTER Region: 1 City: AIBONITO State: PR County: License #: 52-2117501 Agreement: N Docket: NRC Notified By: MARCOS TORRES HQ OPS Officer: OSSY FONT |
Notification Date: 01/22/2019 Notification Time: 08:36 [ET] Event Date: 01/21/2019 Event Time: 09:00 [ATL] Last Update Date: 01/22/2019 |
| Emergency Class: NON EMERGENCY 10 CFR Section: 36.83(a)(10) - POOL COND HIGH |
Person (Organization): MEL GRAY (R1DO) NMSS_EVENTS_NOTIFICATION (EMAIL) |
Event Text
| IRRADIATOR POOL WATER CONDUCTIVITY EXCEEDS LIMIT During a routine surveillance, oil was seen in the pool with the underwater irradiator. Testing found that the pool's conductivity was 180 micro Siemens per centimeter (æS/cm), exceeding the 20 æS/cm regulatory limit and the 100 æS/cm reportability limit. The licensee is currently filtering the water to clean up the pool and at the time of the notification had lowered the conductivity to 160 æS/cm. Additional filters are being purchased and the licensee estimates a few more days before the conductivity will be below the regulatory limit. A leaking chiller was identified as the source of the oil. An assessment is being conducted to either repair or replace the chiller. |