Event Notification Report for June 22, 2018

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/21/2018 - 06/22/2018

EVENT NUMBERS
5346753469

Power Reactor
Event Number: 53467
Facility: WATTS BAR
Region: 2     State: TN
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ANTHONY PATE
HQ OPS Officer: THOMAS KENDZIA
Notification Date: 06/22/2018
Notification Time: 12:14 [ET]
Event Date: 06/22/2018
Event Time: 08:41 [EDT]
Last Update Date: 06/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
GERALD MCCOY (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 95 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP

"At 0841 EDT on June 22, 2018, the Watts Bar Unit 2 reactor automatically tripped while operating at 95% power. All control and shutdown bank rods inserted properly in response to the automatic reactor trip. All safety systems including Auxiliary Feedwater actuated as designed. The plant is stable with decay heat removal through Auxiliary Feedwater and Steam Dump Systems.

"The reactor automatically tripped due to a main turbine trip. The turbine trip was caused by main generator electrical trip. An investigation is in progress.

"The automatic actuation of the Reactor Protection System (RPS) is being reported as a four hour report under 10 CFR 50.72 (b)(2)(iv)(B).

"The expected actuation of the Auxiliary Feedwater System (an engineered safety feature) is being reported as an eight hour report under 10 CFR 50.72 (b)(3)(iv)(A).

"The NRC Senior Resident Inspector has been notified for this event."

The plant is currently stable at normal operating temperature and pressure. The grid is stable and the plant is in its normal shutdown electrical lineup. Unit 1 was unaffected by the Unit 2 trip.


Power Reactor
Event Number: 53469
Facility: VOGTLE
Region: 2     State: GA
Unit: [3] [4] []
RX Type: [3] W-AP1000,[4] W-AP1000
NRC Notified By: DANIEL MICKINAC
HQ OPS Officer: VINCE KLCO
Notification Date: 06/22/2018
Notification Time: 15:12 [ET]
Event Date: 06/22/2018
Event Time: 09:00 [EDT]
Last Update Date: 06/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
GERALD MCCOY (R2DO)
FFD GROUP (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Under Construction 0 Under Construction
4 N N 0 Under Construction 0 Under Construction
Event Text
NON-LICENSED SUPERVISORY CONTRACTOR SUBVERTS FITNESS FOR DUTY TEST

"At 0900 [EDT] on June 22, 2018, a non-licensed supervisory contractor subverted a random Fitness for Duty test. The contractor's site access has been terminated. The NRC Resident Inspector was notified. "