Event Notification Report for November 13, 2017
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 11/09/2017 - 11/13/2017 ** EVENT NUMBERS ** | | Non-Agreement State | Event Number: 53050 | Rep Org: AGILENT TECHNOLOGIES Licensee: AGILENT TECHNOLOGIES Region: 1 City: WILMINGTON State: DE County: License #: 07-28762-01 Agreement: N Docket: NRC Notified By: DAVID BENNETT HQ OPS Officer: STEVEN VITTO | Notification Date: 11/03/2017 Notification Time: 09:34 [ET] Event Date: 10/03/2017 Event Time: [EDT] Last Update Date: 11/03/2017 | Emergency Class: NON EMERGENCY 10 CFR Section: 20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X | Person (Organization): RAY MCKINLEY (R1DO) DENNIS ALLSTON (ILTA) NMSS_EVENTS_NOTIFICA (EMAI) | Event Text LOSS NI-63 GAS CHROMATOGRAPH SOURCE On October 3, 2017, Agilent Technologies was notified of a potential loss of an electron capture detector (ECD) that is a component of a gas chromatograph. The ECD contains an embedded sealed source (Ni-63; 15 milliCuries). The device was being shipped from Syngenta Crop Protection LLC., Greensboro, NC, to CSC, LLC. field repair center in Winchester, Tennessee. The gas chromatograph was packaged on June 28, 2017 with an estimated shipment date during the week July 3, 2017. The carrier is not known at this time. The device has not been located at the repair site. An investigation is being performed by the licensee to locate the device. The ECD source serial number YA779, Model 1533, SSD: NR-0348-D-111-B. Agilent Technologies holds an NRC license (07-28762-01) and is located at 2850 Centerville Road, Wilmington, DE 19808. * * * UPDATE AT 1430 EDT ON 11/3/17 FROM DAVID BENNETT TO JEFF HERRERA * * * The device was located at the repair center by repair center personnel. The device will to be returned to the licensee. Notified the R1DO (McKinley), ILTAB (via email), NMSS (via email). | | Power Reactor | Event Number: 53067 | Facility: PRAIRIE ISLAND Region: 3 State: MN Unit: [ ] [2] [ ] RX Type: [1] W-2-LP,[2] W-2-LP NRC Notified By: BRIAN JOHNSON HQ OPS Officer: VINCE KLCO | Notification Date: 11/13/2017 Notification Time: 03:57 [ET] Event Date: 11/12/2017 Event Time: 03:03 [CST] Last Update Date: 11/13/2017 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION | Person (Organization): DAVID HILLS (R3DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 2 | N | N | 0 | Hot Shutdown | 0 | Hot Shutdown | Event Text CONTAINMENT SPRAY PUMP CONTROL SWITCHES OUT OF SERVICE "At 2119 [CST] on 11/12/2017 a Control Room board walk down discovered that both of the Unit 2 Containment Spray Pump control switches were in pull-out. With the control switches in pull-out, the pumps would not automatically start as required. Unplanned TS [Technical Specifications] 3.0.3 was entered at 2119 as a result of not complying with TS 3.6.5, Containment Spray and Cooling Systems, which requires both trains of Containment Spray to be Operable while in Mode 4. Unit 2 had entered Mode 4 at 0303 on 11/12/2017. TS 3.0.3 was exited at 2127 on 11/12/2017 when both Containment Spray Pump control switches were placed in Automatic restoring Operability. Preliminary investigation determined that while Unit 2 was in Mode 5, Surveillance SP 2099, Main Steam Isolation Valve Logic Test, had taken the Containment Spray Pump control switches to pull-out but did not re-align the control switches to automatic after the test was complete. This 8-hour Non-Emergency report is being made per 10 CFR 50.72(b)(3)(v)(D), Accident Mitigation. The NRC Senior Resident Inspector has been informed." | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021