Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for June 20, 2017

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
06/19/2017 - 06/20/2017

** EVENT NUMBERS **


52799 52813

Agreement State Event Number: 52799
Rep Org: WISCONSIN RADIATION PROTECTION
Licensee: AMERICAN RED CROSS BLOOD SERVICES
Region: 3
City: MADISON State: WI
County:
License #: WI-170008
Agreement: Y
Docket:
NRC Notified By: KYLE WALTON
HQ OPS Officer: JEFF HERRERA
Notification Date: 06/09/2017
Notification Time: 17:04 [ET]
Event Date: 06/09/2017
Event Time: [CDT]
Last Update Date: 06/09/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
ROBERT ORLIKOWSKI (R3DO)
NMSS_EVENTS_NOTIFICA (EMAI)

Event Text

AGREEMENT STATE REPORT - IRRADIATOR DRAWER STUCK IN INTERMEDIATE POSITION

"On June 9, 2017 it was reported to the department that, following a routine irradiation of two samples, the drawer containing the irradiated material ground to a halt while being raised from the irradiation position. The drawer is currently stuck in an intermediate position. Following the halting of the device, the licensee immediately removed it from service and contacted the manufacturer to schedule servicing of the device. Area monitors indicate that there are no elevated radiation levels. The device is J.L. Shepherd Model 143-45-C irradiator. The department will dispatch inspectors to perform an investigation."

WI Event Report ID No.: WI-170008

Power Reactor Event Number: 52813
Facility: COOPER
Region: 4 State: NE
Unit: [1] [ ] [ ]
RX Type: [1] GE-4
NRC Notified By: ARIC HARRIS
HQ OPS Officer: DONALD NORWOOD
Notification Date: 06/20/2017
Notification Time: 03:31 [ET]
Event Date: 06/19/2017
Event Time: 21:15 [CDT]
Last Update Date: 06/20/2017
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
VINCENT GADDY (R4DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation

Event Text

PRIMARY CONTAINMENT DECLARED INOPERABLE DUE TO FAILURE OF DRYWELL TO SUPPRESSION CHAMBER VACUUM BREAKER TO FULLY CLOSE

"This report is being made pursuant to 10 CFR 50.72(b)(3)(v)(D), 'any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident.'

"At time 2115 CDT on June 19, 2017, one torus to drywell vacuum breaker failed to indicate that it was closed after being cycled for surveillance testing. The vacuum breaker had been cycled open and then closed to satisfy SR 3.6.1.8.2 - Perform a functional test of each required vacuum breaker. Failure of the vacuum breaker to indicate closed after the control switch was taken to the closed position represents a failure to satisfy SR 3.6.1.8.2 and SR 3.6.1.8.1 - Verify each vacuum breaker is closed. Primary containment is allowed to have a bypass area between the drywell and suppression chamber less than or equivalent to a one inch diameter hole. The are of bypass was indeterminate while the vacuum breaker did not indicate fully closed. Primary containment was declared inoperable during the time the vacuum breaker did not indicate fully closed.

"The vacuum breaker control switch was subsequently cycled open and closed one additional time. At time 2311 CDT, the vacuum breaker indicated fully closed. At that time, primary containment was declared operable.

"Currently, all twelve Drywell to Suppression Chamber vacuum relief valves are closed and in the normal line-up.

"The NRC Senior Resident Inspector has been notified."

Page Last Reviewed/Updated Tuesday, September 08, 2026

Page Last Reviewed/Updated Tuesday, September 08, 2026