Event Notification Report for October 25, 2016
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 10/24/2016 - 10/25/2016 ** EVENT NUMBERS ** | | Non-Agreement State | Event Number: 52296 | Rep Org: BAYER CORPSCIENCE LP Licensee: BAYER CORPSCIENCE LP Region: 3 City: KANSAS CITY State: MO County: License #: 24-03830-01 Agreement: N Docket: NRC Notified By: STEVEN SCHERICH HQ OPS Officer: DONG HWA PARK | Notification Date: 10/14/2016 Notification Time: 14:17 [ET] Event Date: 10/13/2016 Event Time: 15:00 [CDT] Last Update Date: 10/14/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 30.50(b)(2) - SAFETY EQUIPMENT FAILURE | Person (Organization): RICHARD SKOKOWSKI (R3DO) NMSS_EVENTS_NOTIFIC (EMAI) | Event Text STUCK SHUTTER ON A DENSITY GAUGE The licensee Radiation Safety Officer (RSO) determined that the shutter to a Berthold Model LB7442 gauge with a 1 Ci Cs-137 source (serial number: 012\06) did not shut during biannual maintenance checks. Personnel is informed about the gauge with proper signage, and the RSO does not believe any exposure to personnel occurred, because the shutter is normally in the open position. A licensed Berthold technician has been contacted and will come to the site to repair the gauge. The licensee notified NRC Region 3 (Nieves). | | Agreement State | Event Number: 52298 | Rep Org: PA BUREAU OF RADIATION PROTECTION Licensee: BRASKEM AMERICA, INC Region: 1 City: MARCUS HOOK State: PA County: License #: PA-1021 Agreement: Y Docket: NRC Notified By: JOSEPH MELNIC HQ OPS Officer: DONALD NORWOOD | Notification Date: 10/17/2016 Notification Time: 14:40 [ET] Event Date: 10/15/2016 Event Time: [EDT] Last Update Date: 10/17/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): CHRISTOPHER CAHILL (R1DO) NMSS_EVENTS_NOTIFICA () | Event Text AGREEMENT STATE REPORT - DENSITY GAUGE SHUTTER STUCK IN OPEN POSITION The following information was received via facsimile: "The licensee discovered this event on October 15, 2016 and notified the Department [PA Department of Radiation Protection] on October 15, 2016 via voice message after business hours. It is reportable within 24 hours per 10 CFR 30.50(b)(2). "During normal daily operations, a density gauge was found to have a shutter that was nonresponsive and stuck in the open position. No overexposures have occurred and the gauge has been taken out of service. A service provider has already made the necessary repairs as of today, October 17, 2016. The gauge is an Ohmart/Vega Model SHLG. The serial number of the device is unknown at this time. The device originally contained 1200 millicuries of Cs-137. "The cause of the event is unknown at this time. "A reactive inspection is planned by the Department. More information will be provided upon receipt." Pennsylvania Event Report ID No: PA160031 | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021