Event Notification Report for July 20, 2016
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 07/19/2016 - 07/20/2016 ** EVENT NUMBERS ** | | Agreement State | Event Number: 52081 | Rep Org: FLORIDA BUREAU OF RADIATION CONTROL Licensee: METRIC ENGINEERING Region: 1 City: MIAMI State: FL County: License #: Agreement: Y Docket: NRC Notified By: KELLIE ANDERSON HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 07/12/2016 Notification Time: 16:41 [ET] Event Date: 07/12/2016 Event Time: [EDT] Last Update Date: 07/12/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): MARC FERDAS (R1DO) NMSS_EVENTS_NOTIFICA (EMAI) | | This material event contains a "Less than Cat 3 " level of radioactive material. | Event Text AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE A Troxler moisture density gauge was stolen overnight from a locked overpack in a truck. The gauge contained both Am-241 and Cs-137 sources. The licensee contacted local law enforcement. Gauge serial number: 34700 Florida Incident: FL16-079 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf | | Power Reactor | Event Number: 52106 | Facility: SOUTH TEXAS Region: 4 State: TX Unit: [1] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: DANIEL TURKASZ HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 07/19/2016 Notification Time: 17:58 [ET] Event Date: 07/13/2016 Event Time: 11:00 [CDT] Last Update Date: 07/19/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(2)(xi) - OFFSITE NOTIFICATION | Person (Organization): MICHAEL VASQUEZ (R4DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text EXERCISE PRESS RELEASES AIRED ON RADIO AS AN ACTUAL EVENT "During the planned NRC/FEMA evaluated drill exercise on 7/13/16, two press releases written in the Joint Information Center (JIC) were published in the Public Information and Emergency Response (PIER) system without 'THIS IS A DRILL' denoted at the top of the page. The original press release was stamped with 'THIS IS A DRILL' at the top of page 1 and at the bottom of page 2. When it was added into the PIER system for publication/faxing, it was not noticed the top of the document denoting 'THIS IS A DRILL' was cut off. "The local radio station affiliate was not aware of STP's [South Texas Project's] exercise on 7/13/16. As a result, the affiliate station thought it was a real event and read the press releases over the airwaves at 1014 [CDT] and again at 1046 [CDT]. "At approximately 1400 [CDT] on the same day, the radio station told their listening audience of the mistake and stated STP was having a training exercise not a real event. The correction was broadcast over the airwaves three times every hour until midnight. "This unplanned media event is being reported in accordance with 10CFR50.72(b)(2)(xi). This event is not significant with respect to the health and safety of the public." The licensee notified the NRC Resident Inspector. | |
Page Last Reviewed/Updated Thursday, August 27, 2026
Page Last Reviewed/Updated Thursday, August 27, 2026