Event Notification Report for June 8, 2016
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 06/07/2016 - 06/08/2016 ** EVENT NUMBERS ** | | Agreement State | Event Number: 51966 | Rep Org: FLORIDA BUREAU OF RADIATION CONTROL Licensee: ALL STATE ENGINEERING AND TESTING CONSULTANTS, INC. Region: 1 City: HIALEAH State: FL County: License #: 1113-1 Agreement: Y Docket: NRC Notified By: PAUL R. NORMAN HQ OPS Officer: JEFF HERRERA | Notification Date: 05/30/2016 Notification Time: 22:31 [ET] Event Date: 05/29/2016 Event Time: [EDT] Last Update Date: 05/30/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): JON LILLIENDAHL (R1DO) NMSS_EVENTS_NOTIFIC (EMAI) ILTAB (EMAI) | | This material event contains a "Less than Cat 3 " level of radioactive material. | Event Text AGREEMENT STATE - STOLEN TROXLER NUCLEAR DENSITY GAUGE The following report was received from the State of Florida Bureau of Radiation Control via email: "[A] Troxler nuclear density gauge model 3440, device serial number 24596, was checked out from [the licensee's] office on Saturday afternoon, May 28th, to take it for repairs. The locked vehicle containing the gauge was parked in a secured parking garage. The vehicle was stolen at 0708 [EDT] according to surveillance video. The vehicle was discovered missing at approximately 1100 [EDT]. [The] City of Miami Police were called immediately. "Case #160529-161287 filed by [Miami Police]." Troxler gauge source: Am-241/Be - 40mCi, Cs-137 - 8mCi (originally). Florida Incident Number: FL16-069 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf | | Power Reactor | Event Number: 51985 | Facility: FITZPATRICK Region: 1 State: NY Unit: [1] [ ] [ ] RX Type: [1] GE-4 NRC Notified By: MATT McCARTY HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 06/07/2016 Notification Time: 13:07 [ET] Event Date: 06/07/2016 Event Time: 10:30 [EDT] Last Update Date: 06/07/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL | Person (Organization): FRANK ARNER (R1DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text BOTH SECONDARY CONTAINMENT DOORS OPEN SIMULTANEOUSLY "At 1030 EDT on 6/7/2016, both doors of a secondary containment airlock were reported to be simultaneously open for approximately 2 seconds during the normal passage of personnel. The brief time that the doors were simultaneously open constitutes an inoperable condition of secondary containment. Secondary containment differential pressure was maintained throughout the time period that the doors were open. "This event is being reported under 10 CFR 50.72(b)(3)(v)(C) and per the guidance of NUREG-1022, Rev. 3, 'any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to control the release of radioactive material.'" The licensee notified the NRC Resident Inspector. | | Power Reactor | Event Number: 51986 | Facility: VOGTLE Region: 2 State: GA Unit: [3] [4] [ ] RX Type: [3] W-AP1000,[4] W-AP1000 NRC Notified By: DANIEL MICKINAC HQ OPS Officer: MARK ABRAMOVITZ | Notification Date: 06/07/2016 Notification Time: 14:10 [ET] Event Date: 06/07/2016 Event Time: 07:30 [EDT] Last Update Date: 06/07/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 26.719 - FITNESS FOR DUTY | Person (Organization): ANTHONY MASTERS (R2DO) FITNESS FOR DUTY GRO (E-MA) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 3 | N | N | 0 | Under Construction | 0 | Under Construction | | 4 | N | N | 0 | Under Construction | 0 | Under Construction | Event Text FITNESS FOR DUTY A non-licensed contract supervisor had a confirmed positive for a controlled substance during a random fitness-for-duty test. The employee's access to the plant has been terminated. The licensee notified the NRC Resident Inspector. | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021