Event Notification Report for February 2, 2016
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 02/01/2016 - 02/02/2016 ** EVENT NUMBERS ** | | Non-Agreement State | Event Number: 51673 | Rep Org: UNIVERSITY OF MISSOURI Licensee: UNIVERSITY OF MISSOURI Region: 3 City: COLUMBIA State: MO County: License #: 24-00513-32 Agreement: N Docket: NRC Notified By: JACK CRAWFORD HQ OPS Officer: HOWIE CROUCH | Notification Date: 01/22/2016 Notification Time: 12:37 [ET] Event Date: 01/19/2016 Event Time: 10:30 [CST] Last Update Date: 01/22/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 30.50(b)(2) - SAFETY EQUIPMENT FAILURE | Person (Organization): JAMNES CAMERON (R3DO) NMSS_EVENTS_NOTIFIC (EMAI) | Event Text LEAKING NI-63 SOURCE A 15 mCi Ni-63 source (Sealed Source Device Registry # CA0406S214S), used for research and development, was determined to be leaking greater than the 0.005 microCi limit. The leakage contaminated the desktop where it was being used. No personnel contaminations or overexposures occurred. The source was removed from service and is awaiting proper disposal. Decontamination of the desk, which is in a secure area, is in progress. An investigation into the event is in progress. | | Agreement State | Event Number: 51675 | Rep Org: OK DEQ RAD MANAGEMENT Licensee: UNIVERSITY OF OKLAHOMA MEDICAL CENTER Region: 4 City: OKLAHOMA CITY State: OK County: License #: OK-21035-01 Agreement: Y Docket: NRC Notified By: KEVIN SAMPSON HQ OPS Officer: HOWIE CROUCH | Notification Date: 01/22/2016 Notification Time: 16:41 [ET] Event Date: 01/22/2016 Event Time: [CST] Last Update Date: 01/22/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): JAMES DRAKE (R4DO) NMSS_EVENTS_NOTIFIC (EMAI) | Event Text AGREEMENT STATE REPORT - PACKAGE WITH EXTERNAL CONTAMINATION The following information was received from the State of Oklahoma via email: "[The Oklahoma Department of Environmental Quality (OKDEQ)] has been informed that a package sent from University of Oklahoma Medical Center (OK-21035-01) to the University of Oklahoma Health Sciences Center pharmacy (OK-03176-04MD) was found to have approximately 2.1 X 10^6 DPM of removable contamination when it was received by the pharmacy. The package was empty and the contamination appeared to be confined to an area about 3 cm in diameter on a plastic sleeve which enclosed the shipping label. The nuclide has been identified as Tc-99m. OKDEQ will perform a reactive inspection next week." | | Part 21 | Event Number: 51704 | Rep Org: WECTEC LLC (FORMERLY CB&I) Licensee: CB&I LAURENS Region: 1 City: CHARLOTTE State: NC County: License #: Agreement: Y Docket: NRC Notified By: CURTIS CASTELL HQ OPS Officer: HOWIE CROUCH | Notification Date: 02/01/2016 Notification Time: 12:40 [ET] Event Date: 02/01/2016 Event Time: [EST] Last Update Date: 02/01/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 21.21(d)(3)(i) - DEFECTS AND NONCOMPLIANCE | Person (Organization): ERIC MICHEL (R2DO) PART 21/50.55 REACT (EMAI) | Event Text PART 21 REPORT REGARDING DEVIATIONS OF PIPE SPOOLS FOR AP1000 PROJECTS The following information is summarized from notification received by WECTEC, LLC via email: "The basic components being supplied are piping spools to be used for various safety-related systems for the V. C. Summer and Vogtle AP1000r projects. The pipe spools are classified as ASME Boiler and Pressure Vessel Code Section III. "The specific conditions identified on various piping spools fall into four general categories: (1) Dimensional Length Deviations: These conditions include center-to-end and center-to-center lengths of straight pipe segments that exceed the minimum or maximum tolerances. (2) Bend Angle Deviations: These conditions include spool bend angles that exceed the minimum or maximum tolerances. (3) Minimum Wall Thickness Deviations: These conditions include pipe wall thickness below the applicable tolerance. These conditions typically have been found at some bends in the spools and at some ends of the pipe. (4) Other Conditions: These conditions include weld related attributes, potential carbon contamination, and tools marks." Uninstalled pipe spools are in storage and will be inspected, repaired or replaced prior to installation. Installed products will be identified and issues resolved as appropriate. Name and address of the individual or individuals informing the Commission: David Durham President WECTEC LLC 128 S. Tryon St., Suite 1000 Charlotte, NC 28202 | |
Page Last Reviewed/Updated Thursday, August 27, 2026
Page Last Reviewed/Updated Thursday, August 27, 2026