Event Notification Report for August 21, 2014

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
08/20/2014 - 08/21/2014

** EVENT NUMBERS **


50381 50382 50383 50384

Power Reactor Event Number: 50381
Facility: DAVIS BESSE
Region: 3 State: OH
Unit: [1] [ ] [ ]
RX Type: [1] B&W-R-LP
NRC Notified By: THOMAS COBBLEDICK
HQ OPS Officer: CHARLES TEAL
Notification Date: 08/19/2014
Notification Time: 14:29 [ET]
Event Date: 08/18/2014
Event Time: 19:25 [EDT]
Last Update Date: 08/20/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
DAVE PASSEHL (R3DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation

Event Text

SHIELD BUILDING BOUNDARY DOOR FAILED TO LATCH

"At 1925 EDT on 08/18/2014 an equipment failure prevented a boundary door to the Shield Building Negative Pressure Area to latch closed upon egress, thereby preventing fulfillment of the Station Emergency Ventilation System safety function. Necessary door repairs per normal station practices were completed at 1935 EDT to establish full safety system function.

"This event was previously considered not reportable. Subsequent review determined the event reportable. The NRC Resident has been notified of the event. The failure to meet the 8-hour reporting requirement has been entered into the Corrective Action Program."

The licensee will notify the State, Ottawa, and Lucas counties

* * * UPDATE FROM THOMAS COBBLEDICK TO JOHN SHOEMAKER AT 1027 EDT ON 8/20/14 * * *

"At approximately 0413 [EDT] on 8/20/14, the boundary door to the Shield Building Negative Pressure Area again failed to latch closed upon egress. The door was able to be closed and latched at 0419, restoring the Station Emergency Ventilation System safety function. Door use will be limited to essential activities until final repairs to the door closure and latching mechanism are complete. The NRC Resident has been notified of the event."

The licensee will notify the State of Ohio and local authorities.

Notified R3DO (Passehl).

Power Reactor Event Number: 50382
Facility: KEWAUNEE
Region: 3 State: WI
Unit: [1] [ ] [ ]
RX Type: [1] W-2-LP
NRC Notified By: WILLIAM SWANSON
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 08/20/2014
Notification Time: 09:23 [ET]
Event Date: 08/20/2014
Event Time: 07:47 [CDT]
Last Update Date: 08/20/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
DAVE PASSEHL (R3DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Defueled 0 Defueled

Event Text

SERVICE WATER RETURN RADIATION MONITOR NONFUNCTIONAL FOR PLANNED MAINTENANCE

"On August 20, 2014, at 0747 hours CDT, Kewaunee Power Station rendered the Auxiliary Building Service Water Return Monitor (R-20) nonfunctional for planned maintenance. R-20 is used for Emergency Action Level (EAL) classification of an unplanned release of liquid radioactivity to the environment that would result in an Alert or Unusual Event and is being conservatively reported under 10CFR50.72(b)(3)(xii) as a loss of emergency assessment capability.

"R-20 is planned to be restored to functional by 1400 CDT today, 08/20/2014.

"The NRC Regional Inspector has been notified."

Fuel Cycle Facility Event Number: 50383
Facility: HONEYWELL INTERNATIONAL, INC.
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
Comments: UF6 CONVERSION (DRY PROCESS)
Region: 2
City: METROPOLIS State: IL
County: MASSAC
License #: SUB-526
Agreement: Y
Docket: 04003392
NRC Notified By: ROSS LINBERG
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 08/20/2014
Notification Time: 09:50 [ET]
Event Date: 08/20/2014
Event Time: 03:00 [CDT]
Last Update Date: 08/20/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
40.60(b)(3) - MED TREAT INVOLVING CONTAM
Person (Organization):
JAMES HICKEY (R2DO)
ROBERT JOHNSON (NMSS)

Event Text

UNPLANNED MEDICAL TREATMENT OF A CONTAMINATED INDIVIDUAL

"An employee, with dust in his eye, reported to the on-site dispensary this morning. First aid was administered. A whole body survey of the employee, in his plant clothing, was performed; the maximum amount of contamination present was on the employee's work boots, 44,441 dpm/100cm2. The employee was able to return to work following treatment. The employee remained inside the Restricted Area over the entire course of the event."

There was no contamination in the employee's eye.

The licensee has informed the NRC Region II Senior Fuel Facility Inspector (Hartland) via email.

Fuel Cycle Facility Event Number: 50384
Facility: PORTSMOUTH AMERICAN CENTRIFUGE
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
                   6903 ROCKLEDGE DRIVE
                   BETHESDA, MD 20817
Region: 2
City: PIKETON State: OH
County: PIKE
License #: SNM-2011
Agreement: Y
Docket: 70-7004
NRC Notified By: ERIC SPAETH
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 08/20/2014
Notification Time: 18:21 [ET]
Event Date: 08/20/2014
Event Time: 08:20 [EDT]
Last Update Date: 08/20/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
70.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
JAMES HICKEY (R2DO)
ROBERT JOHNSON (NMSS)

Event Text

AN ISOLATION VALVE DID NOT CLOSE DURING A MAINTENANCE EVOLUTION

"On 8/20/2014, 0820 hrs [EDT], the Plant Shift Superintendent was notified of the following condition:

"During a maintenance evolution to change the machine drive unit (MDU) software, one of the four primary isolation valves comprising the machine isolation valve (MIV) set did not close as required. Specifically, the purge vacuum (PV) isolation valve did not close. All other isolation valves did close as required.

"This event is being reported as a loss or degradation of an IROFS [Item Relied on for Safety] that results in a failure to meet the performance requirements of Section 70.61 [and is reportable per 70.50(b)(2)]."

The licensee will notify the NRC Resident Inspector.