Event Notification Report for June 12, 2013
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 06/11/2013 - 06/12/2013 ** EVENT NUMBERS ** | | Agreement State | Event Number: 49089 | Rep Org: TEXAS DEPARTMENT OF HEALTH Licensee: THE METHODIST HOSPITAL Region: 4 City: State: TX County: HOUSTON License #: 00457 Agreement: Y Docket: NRC Notified By: CHRIS MOORE HQ OPS Officer: CHARLES TEAL | Notification Date: 06/04/2013 Notification Time: 13:33 [ET] Event Date: 06/03/2013 Event Time: [CDT] Last Update Date: 06/04/2013 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): BLAIR SPITZBERG (R4DO) FSME EVENT RESOURCE (EMAI) | Event Text AGREEMENT STATE REPORT - SOURCE RETRACTION FAILURE The following was received from the State of Texas via email: "On June 3, 2013, the Agency [State of Texas] was notified by the licensee that on June 3, 2013, a medical event had occurred. The licensee reported a source retraction failure with a Novoste Beta-Cath intravascular brachytherapy system containing a 45.1 mCi strontium - 90 source. When the treatment was completed, upon source retraction, the source got stuck in another area of the blood vessel roughly 5 cm away from the treatment site for 1 minute. "The unintended absorbed dose to that area of the vessel is in the range of 5-6 Gy. The source open in air time was roughly 3 seconds from being retracted from the patient before being secured in a bail out box. Personnel exposure issues or concerns are not expected, however, dosimeters will be assessed. A technical representative was notified and during the next several days will inspect the system and assist in packaging the system for return shipment back to the manufacturer. Additional information will be provided as it is received in accordance with SA-300." Texas Incident #: I-9088 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | | Power Reactor | Event Number: 49105 | Facility: MILLSTONE Region: 1 State: CT Unit: [1] [ ] [ ] RX Type: [1] GE-3,[2] CE,[3] W-4-LP NRC Notified By: JOHN CLAIRE HQ OPS Officer: DONALD NORWOOD | Notification Date: 06/11/2013 Notification Time: 13:09 [ET] Event Date: 06/11/2013 Event Time: 10:18 [EDT] Last Update Date: 06/11/2013 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): GLENN DENTEL (R1DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | N | 0 | Decommissioned | 0 | Decommissioned | Event Text RADIATION MONITOR OUT-OF-SERVICE FOR PLANNED MAINTENANCE The licensee removed the Spent Fuel Pool Island Radiation Monitor from service for pre-planned maintenance to change the air filter. The radiation monitor was returned to service at 1030 EDT. The licensee notified the NRC Resident Inspector, state and local authorities. | | Power Reactor | Event Number: 49106 | Facility: FARLEY Region: 2 State: AL Unit: [1] [ ] [ ] RX Type: [1] W-3-LP,[2] W-3-LP NRC Notified By: WILLIAM ARENS HQ OPS Officer: CHARLES TEAL | Notification Date: 06/12/2013 Notification Time: 01:33 [ET] Event Date: 06/11/2013 Event Time: 21:05 [CDT] Last Update Date: 06/12/2013 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION 50.72(b)(2)(xi) - OFFSITE NOTIFICATION | Person (Organization): FRANK EHRHARDT (R2DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | A/R | Y | 100 | Power Operation | 0 | Hot Standby | Event Text UNIT 1 AUTOMATIC REACTOR TRIP DUE TO THE LOSS OF A START-UP TRANSFORMER "This is a report of an automatic RPS actuation and automatic ESF actuation per 10CFR50.72(b)(2)(iv)(B) and 10CFR50.72(b)(3)(iv)(A). Additionally, this is to report intentions for a press release per 10CFR50.72(b)(2)(xi). "At 2105 CDT on 6/11/13, Farley Unit 1 experienced an automatic reactor trip from 100% power. The initiating event was the loss of the 1B Start up Transformer which resulted in de-energization of the B-Train ESF 4KV buses and the 1B and 1C Reactor Coolant Pump Buses. The 1B Emergency Diesel Generator auto started and tied to the B-Train 4KV Emergency buses. "Both MDAFW (Motor Driven Auxiliary Feedwater) Pumps and the TDAFW (Turbine Driven Auxiliary Feedwater) Pump auto-started and are supplying AFW flow to the steam generators. Decay heat removal is via the steam dumps to the main condenser. "The cause of the loss of the 1B Start-up Transformer is unknown and is currently under investigation. All other systems functioned as expected in response to the loss of the 1B Start-up Transformer and reactor trip. "The NRC Senior Resident Inspector has been notified. "A press release is planned." All control rods fully inserted. There is no impact on Unit 2. Currently the licensee does not plan to restart the 1B and 1C Reactor Coolant Pumps. Pressurizer spray has been isolated from the 1B loop per procedure. Main Condenser vacuum is adequate for decay heat removal. | |
Page Last Reviewed/Updated Thursday, August 27, 2026
Page Last Reviewed/Updated Thursday, August 27, 2026