Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for July 6, 2012

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
07/05/2012 - 07/06/2012

** EVENT NUMBERS **


48050 48054 48071 48072

Agreement State Event Number: 48050
Rep Org: OR DEPT OF HEALTH RAD PROTECTION
Licensee: METRO METALS
Region: 4
City: PORTLAND State: OR
County: MULTNOMAH
License #:
Agreement: Y
Docket: 12-0551
NRC Notified By: KEVIN SIEBERT
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/27/2012
Notification Time: 11:30 [ET]
Event Date: 06/25/2012
Event Time: 13:00 [PDT]
Last Update Date: 06/27/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JEFF CLARK (R4DO)
FSME RESOURCE (EMAI)

This material event contains a "Less than Cat 3" level of radioactive material.

Event Text

STATIC ELIMINATOR BAR FOUND IN SCRAP YARD

"[Metro Metals] phoned that a flatbed truck with metal scrap from a recycler in WA (Paymore Recycling & Salvage, Montesano, WA) set off their portal monitor. Hand-held exposure meters were used to survey the load and levels were found at 4000 microrem/hr. This load is waiting for RPS [Radiation Protection Services] to check.

"Responded to Metro Metals. Found a static bar. Wrapped and sent back to recycler. Max reading, with Ludlum 2401 EC, at front edge of bar was 6 mR/hr. Exploranium identified Am-241. Static bar was about 5 to 6 feet in length and was cut in half. Item was wrapped in plastic and placed in a drum for return to the recycler."

Radiation Protection Services No: 12-0020

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

Agreement State Event Number: 48054
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: MILLER ENGINEERING & TESTING
Region: 1
City: NORTHBORO State: MA
County:
License #:
Agreement: Y
Docket: 23-4571
NRC Notified By: DOUG CULLEN
HQ OPS Officer: JOE O'HARA
Notification Date: 06/28/2012
Notification Time: 14:18 [ET]
Event Date: 06/28/2012
Event Time: 11:30 [EDT]
Last Update Date: 06/28/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
ANNE DeFRANCISCO (R1DO)
ILTAB VIA EMAIL ()
FSME RESOURCE ()

This material event contains a "Less than Cat 3" level of radioactive material.

Event Text

STOLEN NUCLEAR DENSITY GAUGE

The following was received from the Commonwealth of MA. via fax.

"An automobile with a Nuclear Density Gauge stored in its trunk was stolen from a work site in Roslindale, MA. The nuclear density gauge was manufactured by Campbell-Pacific, Model No. MC3, Serial No. M390204846, containing sealed sources of Cs-137 and Am-241, of less than 10 millicuries and 50 millicuries, respectively. The gauge is licensed with the MA Radiation control Program, with Miller Engineering & Testing of Northboro, MA under license No. 23-4571.

"A police report for the stolen property is being filed with the Boston Police.

"Agency [state] continues with the investigation into this matter, and has asked the licensee for a copy of the police report and subsequent findings. Thus, the investigation remains open."

* * * UPDATE FROM DOUG CULLEN TO JOE O'HARA AT 1607 EDT ON 6/28/12 * * *

The Boston Police Department has recovered the stolen vehicle with the gauge intact in the trunk of the vehicle. The radiation profile is normal for the gauge and the police have notified the company to come and recover the gauge.

Notified R1DO (DeFrancisco) and FSME/ILTAB via e-mail


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source

Power Reactor Event Number: 48071
Facility: SALEM
Region: 1 State: NJ
Unit: [ ] [2] [ ]
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: JASON MORGAN
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 07/05/2012
Notification Time: 17:45 [ET]
Event Date: 07/05/2012
Event Time: 10:00 [EDT]
Last Update Date: 07/05/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
PAMELA HENDERSON (R1DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation

Event Text

VALVE IMPROPERLY ALIGNED FOR ACCIDENT MITIGATION

"On 7/5/12 at 0307 hrs (EDT), Salem Unit 2 declared 21 Auxiliary Feedwater Pump out of service due to the failure of the 23AF21, Auxiliary Feedwater Flow Control valve to the 23 Steam Generator. 23AF21 had failed to a full open position during performance of the in-service test. Salem Unit 2 entered Technical Specification 3.7.1.2 a, Action Statement a, which requires restoring the pump to operable status within 72 hours, otherwise be in at least Hot Standby within the next 6 hrs and in Hot Shutdown within the following 6 hours.

"At 1000 hrs on 7/5/12, the air supply to the 23AF21 was found isolated. Troubleshooting and repair of the 23AF21 was completed and, following in service testing, the valve was declared operable at 1349 hrs.

"Review of the valve's operability concluded that the failure of the 23AF21 valve to close represented a condition that could have prevented fulfillment of a safety function needed to mitigate the consequences of an accident. The Salem UFSAR assumes that during a Category IV Main Steam break accident, a faulted Steam Generator would be identified and Auxiliary Feedwater would be isolated to the affected Steam Generator within 10 minutes. Since the valve was failed open and could not be operated from the control room, the plant would have to manually isolate 23AF21 or trip the 21 Auxiliary Feedwater Pump to ensure feedwater isolation to the affected, faulted Steam Generator. The time to perform manual isolation or tripping of the Auxiliary Feedwater Pump may have required more time than that analyzed by the plant UFSAR.

"This is being reported under 10CFR50.72(b)(3)(v), the nuclear plant being in a condition that could have prevented fulfillment of a safety function needed to mitigate the consequences of an accident.

"There were no other safety related systems affected by this event and there were no injuries associated with this event."

Maintenance was last performed on this system on May 17, 2012.

The licensee will notify the NRC Resident Inspector and Lower Alloways Creek Township.

Power Reactor Event Number: 48072
Facility: MONTICELLO
Region: 3 State: MN
Unit: [1] [ ] [ ]
RX Type: [1] GE-3
NRC Notified By: WILLIAM STANG
HQ OPS Officer: HOWIE CROUCH
Notification Date: 07/05/2012
Notification Time: 21:24 [ET]
Event Date: 07/05/2012
Event Time: 12:58 [CDT]
Last Update Date: 07/05/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
ROBERT DALEY (R3DO)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation

Event Text

UNANALYZED CONDITION DUE TO BLOCKING BOTH REACTOR BUILDING RAILROAD BAY DOORS

"At 1258 CDT on 07/05/2012, Operations was notified that both panels of Door 45 (south doors for the reactor building railroad bay airlock) were blocked by a man lift. Blocking both doors represents an unanalyzed condition as a flow path through the door is assumed for pressure relief during postulated HELB events. The man lift was immediately removed correcting the situation and all work related to Door 45 was stopped. Door 45 was blocked for approximately 20 minutes.

"The NRC Resident Inspector has been notified."