Event Notification Report for July 11, 2011

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/10/2011 - 07/11/2011

EVENT NUMBERS
47040470414704247044

Power Reactor
Event Number: 47040
Facility: COOK
Region: 3     State: MI
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BEN HUFFMAN
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/11/2011
Notification Time: 03:00 [ET]
Event Date: 07/11/2011
Event Time: 04:00 [EDT]
Last Update Date: 07/11/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
DAVID HILLS (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
UNAVAILABILITY OF TSC VENTILATION SYSTEM DUE TO SCHEDULED MAINTENANCE

"At 0400 EDT on Monday, July 11, 2011, the Cook Nuclear Plant (CNP) Technical Support Center (TSC) air conditioning and charcoal filtration systems will be removed from service for scheduled maintenance.

"Under certain accident conditions the TSC may become unavailable due to the inability of the air conditioning and charcoal filtration systems to maintain a habitable atmosphere. Compensatory measures exist to relocate TSC personnel to the unaffected unit's control room if necessary.

"TSC ventilation system maintenance is scheduled to be completed by 2000 EDT on Monday, July 11, 2011.

"The licensee has notified the NRC Resident Inspector.

"This notification is being made in accordance with 10 CFR 50.72 (b)(3)(xiii) due to the loss of an emergency response facility."

* * * UPDATE FROM DAN KURTH TO JOE O'HARA AT 2151 ON 7/11/11 * * *

"TSC ventilation system maintenance was completed satisfactorily and the system restored to service at 1800 EDT on 7/11/11. The NRC Resident Inspector will be notified."

Notified R3DO(Bloomer)


Power Reactor
Event Number: 47041
Facility: PRAIRIE ISLAND
Region: 3     State: MN
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: STEPHEN SEILHYMER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 07/11/2011
Notification Time: 04:00 [ET]
Event Date: 07/11/2011
Event Time: 01:25 [CDT]
Last Update Date: 07/11/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
DAVID HILLS (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
INADVERTENT EMERGENCY SIREN ACTIVATION COINCIDENT WITH ADVERSE WEATHER

"At approximately 0125 CDT on July 11, 2011 licensee was notified by Goodhue County Sheriff's Department of an inadvertent emergency siren activation (R17) in the city of Red Wing, MN. The Sheriff's Department deactivated the siren and notified the siren vendor. Siren initiation was coincident with severe storm activity in the area, including lighting strikes. Siren remains out of service and is the only siren out of service within the 10 mile Emergency Planning Zone (EPZ)."

The licensee informed the NRC Resident Inspector.


Power Reactor
Event Number: 47042
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JOHN A WALKOWIAK
HQ OPS Officer: KARL DIEDERICH
Notification Date: 07/11/2011
Notification Time: 10:58 [ET]
Event Date: 07/11/2011
Event Time: 10:22 [EDT]
Last Update Date: 07/11/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JAMES DWYER (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
TEMPORARY LOSS OF ERDS AND SPDS DUE TO PLANNED MAINTENANCE

"The Emergency Plant Information Computer (EPIC) has been shutdown for planned maintenance. The maintenance is expected to last less than six (6) hours. The shutdown of EPIC has caused a loss of the Safety Parameter Display System (SPDS) and Emergency Response Data System (ERDS). This is determined to be a partial, but significant Loss of Emergency Assessment Capability, and is an 8-hr. Non-Emergency 10 CFR 50.72(b)(3)(xiii) required notification.

"There are no plant transients or power maneuvers in progress or planned.

"Actions taken include: performance of the site specific Computer Out-of-service Surveillance (ST-40C) which provides for enhanced Control Room parameter monitoring, additional operating rounds in-plant on a recurring basis, and restriction of scheduled activities that could cause a plant transient. Members of the JAF [James A Fitzpatrick] Emergency Response Organization (ERO) have been briefed on contingencies required during an E-Plan [Emergency Plan] activation. A contingency plan for around the clock maintenance coverage to recover the EPIC if it is not restored as scheduled does exists."

The licensee has notified the State, the County, and the NRC Resident Inspector.


Agreement State
Event Number: 47044
Rep Org: SC DIV OF HEALTH & ENV CONTROL
Licensee: COLLETON MEDICAL CENTER
Region: 1
City: WALTERBORO   State: SC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: ANDREW ROXBURGH
HQ OPS Officer: JOE O'HARA
Notification Date: 07/12/2011
Notification Time: 14:11 [ET]
Event Date: 07/11/2011
Event Time: 09:00 [EDT]
Last Update Date: 07/12/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES DWYER (R1DO)
CHRIS EINBERG (FSME)
Event Text
AGREEMENT STATE REPORT - POTENTIAL OVEREXPOSURE TO WHOLE BODY (WB) AND HANDS

The following was received via fax:

"The Department of Health and Environmental Control was notified on July 12, 2011 at 10:25 AM by the licensee that it had received notification from Landauer that one of the employees WB and Ring badges exceeded the limits. The licensee stated that the WB badge had a reading of 77480 mR and the Ring badge had a reading of 65468 mR. The employee in question only administered doses to patients 6 out of the 10 days worked during the reporting period. The licensee is authorized for diagnostic administration of radioactive material (Tc-99m and TI-201 ).

"The licensee was advised by [the state] to submit a written report detailing this event to the Department of Health and Environmental Control within 30 days. The event is open and pending the licensee's investigation and report to the Department, updates will be made through the national NMED system."