| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/06/2010 - 12/07/2010 ** EVENT NUMBERS ** | | !!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!! | | General Information | Event Number: 46451 | Rep Org: NV DIV OF RAD HEALTH Licensee: CARDINAL HEALTH Region: 4 City: LAS VEGAS State: NV County: CLARK License #: 03-11-0505-01 Agreement: Y Docket: NRC Notified By: SNEHA RAVIKUMAR HQ OPS Officer: VINCE KLCO | Notification Date: 12/02/2010 Notification Time: 20:45 [ET] Event Date: 12/02/2010 Event Time: 03:20 [PST] Last Update Date: 12/03/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): DALE POWERS (R4DO) JAMES DANNA (FSME) | Event Text AGREEMENT STATE REPORT - EMPLOYEE CONTAMINATIONS DURING CYCLOTRON OPERATION The following information was received by e-mail: The state reported that three employees of Cardinal Health were contaminated by Fluorine 18 (F-18) from operation of a cyclotron. Initial contamination of the employees was 1600 cpm. Soap and water was used to decontaminate the personnel and at 1130 PST the contamination was reported to be 1300 dpm. The licensee believes the cause of the contamination to be faulty delivery lines. The cyclotron device is a General Electric Accelerator PETrace. Nevada Incident Number: NV100022 * * * RETRACTION FROM SNEHA RAVIKUMAR TO ERIC SIMPSON AT 1507 EST ON 12/3/10 * * * The following information was received by email from the State of Nevada: The State of Nevada is retracting the Event Report sent on December 2, 2010, regarding Cardinal Health. This event does not need to be reported based on the fact that a contamination events must restrict access to the area for more than 24 hours or cause doses to workers that exceed regulatory limits in order to be reportable. Due to the short half life of the material involved and the fact that it was limited to the transfer tube, it is unlikely that anyone received a dose >1 ALI (24 hr notification) or >5 ALI (immediate notification). Notified R4DO (Powers) and FSME (McIntosh). | | Power Reactor | Event Number: 46457 | Facility: WOLF CREEK Region: 4 State: KS Unit: [1] [ ] [ ] RX Type: [1] W-4-LP NRC Notified By: PRESTON LAWSON HQ OPS Officer: HOWIE CROUCH | Notification Date: 12/06/2010 Notification Time: 05:42 [ET] Event Date: 12/06/2010 Event Time: 04:18 [CST] Last Update Date: 12/06/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(2)(i) - PLANT S/D REQD BY TS | Person (Organization): DALE POWERS (R4DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 85 | Power Operation | Event Text TECH SPEC REQUIRED SHUTDOWN DUE TO EXCEEDING ALLOWED OUTAGE TIME ON THE 'A' EMERGENCY DIESEL GENERATOR "(KKJ01A) 'A' Emergency Diesel Generator (EDG) was removed from service and declared inoperable [on] 11/29/2010 at 0500 (CST) for a scheduled 7 day Technical Specification equipment outage to perform various scheduled maintenance items. Technical Specification 3.8.1 Condition B was entered for one Diesel Generator inoperable, utilizing Action B.4.2.2, 'Restore the Diesel Generator to OPERABLE within 7 days AND 10 days from discovery of failure to meet LCO'. "On 12/06/2010, it was discovered during the Operability Run Surveillance, STS KJ-015A, utilized to restore the EDG to service, the Engine Analyzer Data Acquisition [software] indicated the No. 12 cylinder is 'out of balance' and will require a clearance order and maintenance repair. On 12/06/2010 [at] 0350 hrs., it was determined that the work required to restore the EDG to service would cause the Tech Spec 3.8.1 Action B.4.2.2 Completion Time requirement of 7 days to be exceeded, requiring a Plant Shutdown per TS 3.8.1 Condition H, with Action H.1, 'Be in Mode 3 within 6 hours', and Action H.2, 'Be in Mode 5 within 36 hours'. "Plant Shutdown to Mode 3 was commenced [on] 12/06/2010 at 0418 (CST). "The [NRC] Resident Inspector has been contacted." The licensee indicated that required repairs should be completed within 8 hours and expects restart to occur on 12/06/2010. | | General Information | Event Number: 46461 | Rep Org: ULTRA ELECTRONICS Licensee: ULTRA ELECTRONICS Region: 4 City: ROUND ROCK State: TX County: WILLIAMSON License #: Agreement: Y Docket: NRC Notified By: MARK MCCRAY HQ OPS Officer: JOHN SHOEMAKER | Notification Date: 12/07/2010 Notification Time: 09:58 [ET] Event Date: 12/06/2010 Event Time: [CST] Last Update Date: 12/07/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: 21.21 - UNSPECIFIED PARAGRAPH | Person (Organization): CHRISTOPHER CAHILL (R1DO) SCOTT SHAEFFER (R2DO) ROBERT DALEY (R3DO) MICHAEL HAY (R4DO) NRR (EMAI) NRO (EMAI) | Event Text FAIL SAFE FUNCTION OF THE N7000 SERIES TEMPERATURE TRANSMITTER DOES NOT OPERATE CORRECTLY UNDER CERTAIN CONDITIONS "The functional issue is limited to N7000 transmitters where the field selectable jumper is set for downscale indication upon loss of input (open circuit, over range RTD, or short circuit). The transmitter may indicate a mid-range output upon open circuit or over range RTD input instead of going downscale (4 mA) as intended. Short circuit detection operates correctly in all cases. "This issue does not affect temperature transmitters during normal operating conditions, only the downscale input sensor failure indication function. N7000 transmitters that have been set for upscale sensor failure indication are not affected; however, this notification is applicable to all N7000 customers because the sensor failure indication is field selectable." The following sites are affected: Oconee, Calvert Cliffs, Perry, North Anna, Surry, Framatome ANP, Kewaunee, Diablo Canyon, and Hope Creek. | | Power Reactor | Event Number: 46463 | Facility: MCGUIRE Region: 2 State: NC Unit: [1] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: RICK JACKSON HQ OPS Officer: VINCE KLCO | Notification Date: 12/07/2010 Notification Time: 18:19 [ET] Event Date: 12/07/2010 Event Time: 15:32 [EST] Last Update Date: 12/07/2010 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(2)(xi) - OFFSITE NOTIFICATION | Person (Organization): JAMES MOORMAN (R2DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text OFFSITE NOTIFICATION DUE TO SEWAGE SPILL "An approximate 14,000 gallon sewage spill was identified outside the plant protected area [coming] from a sewage manhole. The spill was suspected to have begun on 12/6/10. Site personnel have responded and the upstream lift station has been secured which has stopped the spill. The manhole is presently being pumped down at this time. It appears at this time that the spill occurred from a severely corroded clean-out pipe cap. This sewage spill has no effect on safe operation of McGuire Units 1 and 2." The licensee will notify the NRC Resident Inspector and the North Carolina Department of Environment and Natural Resources in Mooresville, NC. | |