Event Notification Report for April 15, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/14/2008 - 04/15/2008

EVENT NUMBERS
4414244140

Power Reactor
Event Number: 44142
Facility: FARLEY
Region: 2     State: AL
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: TIM DRIGGERS
HQ OPS Officer: JOHN KNOKE
Notification Date: 04/15/2008
Notification Time: 17:13 [ET]
Event Date: 04/15/2008
Event Time: 08:49 [CDT]
Last Update Date: 04/15/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(B) - POT RHR INOP
Person (Organization):
KATHLEEN O'DONOHUE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 61 Power Operation 61 Power Operation
Event Text
RESIDUAL HEAT REMOVAL SYSTEM DECLARED INOPERABLE

"At 0849 the B train of service water (SW) AC and DC power distribution systems [were] declared inoperable due to voltage fluctuations below the Tech Spec minimum. During this time the A train of RHR for Unit 1 was inoperable due to an equipment outage. LCO 3.0.3 [was] entered due to both trains [of] RHR inoperable on Unit 1. At 1029 Unit 1 exited LCO 3.0.3 when the A train of RHR was restored. Currently ground isolation efforts are in progress on the B train SW power distribution system."


The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 44140
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: BRIAN PIGG
HQ OPS Officer: JOHN KNOKE
Notification Date: 04/15/2008
Notification Time: 12:50 [ET]
Event Date: 04/15/2008
Event Time: 07:00 [CDT]
Last Update Date: 04/15/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
LAURA KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 99 Power Operation 99 Power Operation
Event Text
HIGH PRESSURE COOLANT INJECTION DECLARED INOPERABLE

"Unit 2 HPCI (High Pressure Coolant Injection) System was declared inoperable due to discovery of a failed flow controller. The controller failure would prevent HPCI from achieving rated flow (safety function). Investigation into cause of failure and preparation for controller replacement are in progress. This event is being reported under 10CFR50.72(b)(3)(v)(B & D)."

The licensee notified the NRC Resident Inspector.

The licensee indicated the Isolation Condenser is operable. A 14 day LCO is in effect.