Event Notification Report for March 9, 2004

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
03/08/2004 - 03/09/2004

** EVENT NUMBERS **


40573 40576

Power Reactor Event Number: 40573
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [1] [ ] [ ]
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: GORDON ROBINSON
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 03/07/2004
Notification Time: 04:06 [ET]
Event Date: 03/06/2004
Event Time: 22:10 [EST]
Last Update Date: 03/08/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
MOHAMED SHANBAKY (R1)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling

Event Text

SPDS WILL BE DE-ENERGIZED FOR MORE THAN 8 HOURS DUE TO REFUELING OUTAGE ACTIVITIES

"At 22:10 on March 6, 2004 the Unit 1 Safety Parameter Display System (SPDS) was deenergized during planned refuel outage activities. It has been determined that it will not be restored within the required eight hours. Currently, restoration is scheduled for March 7, 2004 at 17:00. All required instrumentation is available in the control room.
Since the Unit 1 SPDS computer system will be unavailable for greater than 8 hours, this is considered a Loss of Emergency Assessment Capability and therefore reportable under 10CFR50,72(b)(3)(xiii). Unit 1 is currently in Mode 5 for the planned 13th Refuel and Inspection Outage."


The licensee notified the NRC Resident Inspector

**** Update at 2219 EST on 03/07/04 by Gordon Robinson taken by MacKinnon ****

SPDS is still out of service and it will be restored to service by 0600 EST on 03/08/04. R1DO (M. Shanbaky) notified.

NRC Resident has be notified of the update by the licensee.


* * * UPDATE ON 03/09/04 @ 1122 BY GRANT FERNSLER TO C. GOULD* * *

As of 1117 the SPDS was energized and restored to service.

The NRC Resident Inspector was notified.

Reg 1 RDO(Cobey) was notified.

Power Reactor Event Number: 40576
Facility: PEACH BOTTOM
Region: 1 State: PA
Unit: [2] [ ] [ ]
RX Type: [2] GE-4,[3] GE-4
NRC Notified By: DANIEL FORRY
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/08/2004
Notification Time: 17:04 [ET]
Event Date: 03/08/2004
Event Time: 11:30 [EST]
Last Update Date: 03/08/2004
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
EUGENE COBEY (R1)

Unit SCRAM Code RX CRIT Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation

Event Text

HPCI SYSTEM INOPERABLE DUE TO FAILURE OF TORUS SUCTION VALVE TO FULLY OPEN

"U2 HPCI was declared inoperable to fulfill its safety function to mitigate the consequences of an accident.

"U2 HPCI torus suction valve MO-2-23-058 failed to fully open, during performance of ST-O-023-301-2 'HPCI Pump, Valve, Flow, and Unit Cooler Functional and In-Service Test.' The valve stopped in a mid-position. HPCI flow path from Condensate Storage Tank remains available for HPCI injection. Investigation into cause is continuing."

The licensee notified the NRC Resident Inspector.