Event Notification Report for December 31, 2003
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/30/2003 - 12/31/2003 ** EVENT NUMBERS ** | | Power Reactor | Event Number: 40418 | Facility: FT CALHOUN Region: 4 State: NE Unit: [1] [ ] [ ] RX Type: [1] CE NRC Notified By: ERICK MATZKE HQ OPS Officer: CHAUNCEY GOULD | Notification Date: 12/30/2003 Notification Time: 12:27 [ET] Event Date: 12/30/2003 Event Time: 08:30 [CST] Last Update Date: 12/30/2003 | Emergency Class: NON EMERGENCY 10 CFR Section: 26.73 - FITNESS FOR DUTY | Person (Organization): Tom Farnholtz (R4) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text LICENSED EMPLOYEE FAILED A RANDOM FITNESS FOR DUTY ALCOHOL TEST Contact the HOO for additional details. The NRC Resident Inspector was notified | | Power Reactor | Event Number: 40419 | Facility: COOK Region: 3 State: MI Unit: [ ] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: SCOTT RICHARDSON HQ OPS Officer: CHAUNCEY GOULD | Notification Date: 12/30/2003 Notification Time: 15:01 [ET] Event Date: 12/30/2003 Event Time: 13:30 [EST] Last Update Date: 12/30/2003 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION | Person (Organization): KENNETH RIEMER (R3) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 2 | A/R | Y | 100 | Power Operation | 0 | Hot Standby | Event Text REACTOR TRIPPED FROM 100% POWER DUE TO LOW STEAM GENERATOR Cook unit 2 automatically tripped from 100% power due to low steam generator level coincident with feed flow less than steam flow. The cause of this condition is under investigation, but it is suspected that unplanned closure of the steam generator 2 & 3 feedwater isolation valves led to the initiating signal. It is believed that the feedwater isolation valve closure originated from an abnormality in the Control Room Instrument Distribution(CRID) 120VAC power system. Technicians were landing leads on a Residual Heat Removal (RHR) System flow transmitter which was fed from the suspected CRID supply at the time of the event. An arc was observed during the lead landing procedure. The main generator also required a manual trip signal by control room operators due to sticking of the main stop valve which is also being investigated. All other systems responded as expected. All rods fully inserted, no ECCS actuation occurred, and no relief valves lifted. The unit is stable in mode 3 with aux feedwater providing heat sink supply. The NRC Resident Inspector has been informed. | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021