Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for July 9, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           07/08/2003 - 07/09/2003



                              ** EVENT NUMBERS **



39975  39976  39982  39984  39985  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39975       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 07/03/2003|

|LICENSEE:  H&G INSPECTION                       |NOTIFICATION TIME: 17:59[EDT]|

|    CITY:  Texas City               REGION:  4  |EVENT DATE:        05/20/2003|

|  COUNTY:                            STATE:  TX |EVENT TIME:        14:30[CDT]|

|LICENSE#:  L02181                AGREEMENT:  Y  |LAST UPDATE DATE:  07/03/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CHARLES MARSCHALL    R4      |

|                                                |THOMAS ESSIG         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  HELEN WATKINS                |                             |

|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OVEREXPOSURE                                                                 |

|                                                                              |

| Event occurred on May 20, 2003 between the hours of 0200 and 0230 hours CDT  |

| at the Amoco Refinery in Texas City, TX. Overexposure was reported to the    |

| Texas Dept. of Health on July 3, 2003.                                       |

|                                                                              |

| "A radiography source was not cranked into the fully shielded position       |

| resulting in a 6.403 R whole body exposure to a radiographer.  The           |

| radiographer was making wall thickness exposures using a 100 curie cobalt 60 |

| source with a directional collimator.  The radiographer made the last        |

| exposure for the night, then proceeded to retrieve the film and take it for  |

| development in the darkroom.  The radiographer believed the pigtail had been |

| fully retracted, however, his initial survey was not conclusive because his  |

| survey meter was not turned on.  Although the ratemeter was alarming,        |

| because of the noise level and the ear plugs, he did not initially hear      |

| ratemeter alarming.  When he did hear the faint ringing he checked the meter |

| and it was off. When the radiographer turned the meter on and resurveyed the |

| guide tubes, the needle went off-scale.  He checked his pocket dosimeter and |

| it was off scale.  The radiographer then retracted the pigtail into the      |

| fully shielded position.  The radiographers reported the event to their      |

| management by telephone, then returned to the company shop.                  |

|                                                                              |

| "The following day the personnel monitoring badge was sent for emergency     |

| processing.  The radiographer believes he was exposed for about one minute.  |

|                                                                              |

| "We will provide additional information as it is collected"                  |

|                                                                              |

| Source Production & Equipment Company.                                       |

| Source Information:                                                          |

| Model G-70 sn# C60-02                                                        |

| 101 Curies cobalt-60 on May 29, 2002 (3737GBq)                               |

|                                                                              |

| Texas Incident No:  I-8033                                                   |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39976       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 07/03/2003|

|LICENSEE:  SUNOCO CHEMICALS                     |NOTIFICATION TIME: 18:41[EDT]|

|    CITY:  LaPorte                  REGION:  4  |EVENT DATE:        06/19/2003|

|  COUNTY:                            STATE:  TX |EVENT TIME:        06:45[CDT]|

|LICENSE#:  L02778                AGREEMENT:  Y  |LAST UPDATE DATE:  07/03/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CHARLES MARSCHALL    R4      |

|                                                |THOMAS ESSIG         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  HELEN WATKINS                |                             |

|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| DAMAGED TEXAS NUCLEAR MODEL 5180A LEVEL GAUGE                                |

|                                                                              |

| "An explosion and fire occurred in a distillation unit.  The operating units |

| were shut down and the fire was extinguished.  A visual inspection of a      |

| level gauge installed on a vessel located in the area showed the device was  |

| intact with no apparent physical damage except heat discoloration was        |

| visible on the device.  A preliminary survey found no readings above the     |

| regulatory limits.  However, an attempt to close the shutter was made and    |

| debris and molten materials made the closing difficult.  A wipe test was     |

| performed with no leakage found.  The device and area was barricaded to      |

| prevent unauthorized entry.                                                  |

|                                                                              |

| "Consultant Assistance:                                                      |

| A radiation technician from Alpha Process Sales inspected the device and the |

| area.  Occupancy surveys were made and showed no persons who entered the     |

| area received exposures over the allowable limits.                           |

|                                                                              |

| "Thermo-Measuretech of Round Rock, TX, an authorized company, removed the    |

| device and took possession for disposal.                                     |

|                                                                              |

| "TX Nuclear Level Gauge                                                      |

| TN model 5180A                                                               |

| source sn# B380, 500mCi [millicuries] Cs-137"                                |

|                                                                              |

| Texas Incident No: I-8032                                                    |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39982       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: LASALLE                  REGION:  3  |NOTIFICATION DATE: 07/08/2003|

|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 02:52[EDT]|

|   RXTYPE: [1] GE-5,[2] GE-5                    |EVENT DATE:        07/07/2003|

+------------------------------------------------+EVENT TIME:        23:19[CDT]|

| NRC NOTIFIED BY:  LARRY BLUNK                  |LAST UPDATE DATE:  07/08/2003|

|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHRIS MILLER         R3      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     A/R        Y       100      Power Operation  |0        Hot Shutdown     |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC REACTOR SCRAM AT LaSALLE UNIT 2 DUE TO TRIP OF THE MAIN TURBINE    |

|                                                                              |

| "At 2319 CDT on July 7, 2003 LaSalle Unit 2 Automatically scrammed due to a  |

| trip of the main turbine. The main turbine trip was caused by a main         |

| generator lockout due to a fault on the "B" phase of the main power          |

| disconnect. All rods inserted on the scram. Three safety relief valves       |

| actuated in the relief mode on the turbine trip. Both reactor recirc pumps   |

| tripped off and all three circulation water pumps tripped off. The main      |

| steam line isolation valves and main steam line drains were closed due to    |

| the loss of the circulating water pumps. Tech Spec 3.0.3 was entered due to  |

| simultaneous inoperability of A, B, and C residual heat removal pumps. "A"   |

| residual heat removal pump was declared inoperable due to use in suppression |

| pool cooling. "B" and "C" residual heat removal pumps were inoperable at the |

| beginning of the event for planned [preventive] maintenance on the essential |

| core cooling system ventilation. There were no automatic actuations of ECCS  |

| systems and no primary or secondary containment isolation system actuations. |

| There [were] no ECCS injections into the reactor vessel. There were 3        |

| subsequent auto scram signals on low reactor level due to level shrink on    |

| SRV closure in pressure control."                                            |

|                                                                              |

| Unit 2 is currently stable with reactor feedwater being provided by the      |

| condensate system and reactor heat removal using SRV steam discharge to the  |

| suppression pool. Residual heat removal pumps "A" and "B" are operating to   |

| provide suppression pool cooling. "C" residual heat removal pump has been    |

| returned to operable status. All emergency diesel generators are available.  |

|                                                                              |

| The licensee also reported that the electrical system transient resulted in  |

| the need to reduce power on LaSalle Unit 1 from 100% to ~92% to stabilize    |

| condensate booster pump suction pressure.                                    |

|                                                                              |

| The licensee has notified the NRC Resident Inspector                         |

|                                                                              |

| * * * UPDATE ON 7/8/03 AT 1108 EDT FROM DANIEL COVEYOU TO GERRY WAIG * * *   |

|                                                                              |

| "At 0306 [CDT] on 7/8/03 there was an automatic RPS [Reactor Protection      |

| System] actuation due to reactor water level 3. At the time of the scram all |

| control rods were already fully inserted. There was no rod movement as a     |

| result of the 0306 [CDT] auto reactor scram. The low level condition was a   |

| momentary response due to level shrink upon safety relief valve closure. The |

| safety relief valves were being manually operated to control reactor         |

| pressure."                                                                   |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

|                                                                              |

| Notified R3DO ( Chris Miller)                                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39984       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: ROBINSON                 REGION:  2  |NOTIFICATION DATE: 07/08/2003|

|    UNIT:  [2] [] []                 STATE:  SC |NOTIFICATION TIME: 16:42[EDT]|

|   RXTYPE: [2] W-3-LP                           |EVENT DATE:        07/08/2003|

+------------------------------------------------+EVENT TIME:        10:58[EDT]|

| NRC NOTIFIED BY:  CHUCK BAUCOM                 |LAST UPDATE DATE:  07/08/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |THOMAS DECKER        R2      |

|10 CFR SECTION:                                 |                             |

|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOSS OF COMMUNICATIONS CAPABILITY                                            |

|                                                                              |

| "At approximately 10:58 hours (EDT) on July 8, 2003, a fiber optic cable     |

| that provides service to H. B. Robinson Steam Electric Plant (HBRSEP), Unit  |

| No. 2, was removed from service due to highway bridge repairs on State Road  |

| 23, Old Camden Road, approximately 1.5 miles west of the plant site. This    |

| resulted in the loss of circuits supported by Bellsouth, which includes the  |

| selective signaling system for communication with the state and counties, an |

| additional phone system for internal and external communication called ESSX, |

| the NRC T1 link, and dial 9 service from the internal plant telephone        |

| system. Communications capability remained available via the on-site PBX     |

| telephone service, cellular phone service, satellite phone, and the Progress |

| Energy Voicenet system.                                                      |

|                                                                              |

| "At approximately 09:00 hours [EDT], Bellsouth personnel informed HBRSEP,    |

| Unit No. 2, personnel of the plan to temporarily remove the cable from       |

| service at approximately 11:00 hours [EDT] in support of the bridge repair   |

| work. HBRSEP, Unit No. 2, Emergency Preparedness personnel notified the      |

| control room Superintendent of Shift Operations pertaining to the impending  |

| communications outage and verified that a cellular phone and satellite phone |

| were available in the control room. The state and county emergency operation |

| centers, warning points, and back-up warning points were notified of the     |

| planned communications link outage prior to its removal from service. The    |

| fiber optic cable was placed back in service at approximately 14:51 hours    |

| [EDT] and the systems were subsequently tested satisfactorily.               |

|                                                                              |

| "This report is being made in accordance with 10 CFR 50.72(b)(3)(xiii),      |

| which is any event that results in a major loss of offsite communications    |

| capability. The capability to provide notification as required was           |

| maintained by use of alternate systems, specifically cellular phone,         |

| satellite phone, and the Progress Energy Voicenet system. The resident       |

| inspector has been notified."                                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39985       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COMANCHE PEAK            REGION:  4  |NOTIFICATION DATE: 07/09/2003|

|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 03:05[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        07/09/2003|

+------------------------------------------------+EVENT TIME:        01:09[CDT]|

| NRC NOTIFIED BY:  LES MILLER                   |LAST UPDATE DATE:  07/09/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |KRISS KENNEDY        R4      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     A/R        Y       99       Power Operation  |0        Hot Standby      |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC REACTOR TRIP DUE TO REACTOR COOLANT PUMP BREAKER OPENING WITH      |

| INITIATION OF AUXILIARY FEEDWATER SYSTEM AFTER THE TRIP                      |

|                                                                              |

| "At 0109 hrs. CDT, Unit 2 reactor tripped due to opening of RCP [Reactor     |

| Coolant Pump] 2-04 breaker resulting in "Rx >48% 1/4 loop flow low trip".    |

| Cause of the breaker opening is unknown and under investigation.  All        |

| systems responded as required.  Auxiliary Feed Water auto-start occurred due |

| to steam generator shrink, both motor driver AFW pumps and Turbine Driven    |

| AFW pump started (ESF)."                                                     |

|                                                                              |

| All rods inserted into the core during the trip.  The electrical grid is     |

| stable.  There were no power-operated or manual relief valve lifts during    |

| the transient.  The other unit was not affected by the transient.  Decay     |

| heat is being removed via steam generator blowdown and AFW.  The plant is    |

| maintaining at NOP/NOT in mode 3 until the cause of the breaker trip is      |

| known and repaired.  Pressurizer pressure control is in automatic.  There is |

| no identified primary-to-secondary leakage.                                  |

|                                                                              |

| The licensee has informed the NRC Resident Inspector.                        |

+------------------------------------------------------------------------------+





                    