Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 23, 2003




                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           06/20/2003 - 06/23/2003



                              ** EVENT NUMBERS **



39952  39954  39955  



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39952       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 06/20/2003|

|    UNIT:  [1] [2] []                STATE:  TN |NOTIFICATION TIME: 16:08[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/11/2003|

+------------------------------------------------+EVENT TIME:        22:00[EDT]|

| NRC NOTIFIED BY:  JAY WHITWORTH                |LAST UPDATE DATE:  06/20/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |LEONARD WERT         R2      |

|10 CFR SECTION:                                 |                             |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION TO STATE OF TENNESSEE MADE DUE TO LOSS OF POWER TO      |

| EMERGENCY SIRENS                                                             |

|                                                                              |

| The following information was obtained from the licensee via facsimile:      |

|                                                                              |

| "On June 11, 2003, 23 of the 108 emergency sirens were out of service        |

| because of a storm passing through the area, causing power outages.  The TVA |

| Operations Duty Specialist notified the State of Tennessee of the loss of    |

| the sirens. This report is being made to NRC in accordance with 10 CFR       |

| 50.72(b)(2)(xi) as a situation, related to the health and safety of the      |

| public or on-site personnel, or protection of the environment, for which a   |

| news release is planned or notification to other government agencies has     |

| been made.  As power was restored to the area, the sirens were returned to   |

| service.                                                                     |

|                                                                              |

| "This report is being made at this time since Sequoyah Operations personnel  |

| have become aware that the State of Tennessee was notified by the TVA        |

| Operations Duty Specialist on June 11, 2003."                                |

|                                                                              |

| The TVA Operations Duty Specialist is based in a location different from the |

| Sequoyah plant.                                                              |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Other Nuclear Material                           |Event Number:   39954       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  NUCOR STEEL                          |NOTIFICATION DATE: 06/21/2003|

|LICENSEE:  NUCOR STEEL                          |NOTIFICATION TIME: 13:50[EDT]|

|    CITY:  CRAWFORDSVILLE           REGION:  3  |EVENT DATE:        06/21/2003|

|  COUNTY:                            STATE:  IN |EVENT TIME:        11:50[CST]|

|LICENSE#:  13-25975-01           AGREEMENT:  N  |LAST UPDATE DATE:  06/21/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KENNETH RIEMER       R3      |

|                                                |C.W. (BILL) REAMER   NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  JEFF JORDAN                  |                             |

|  HQ OPS OFFICER:  HOWIE CROUCH                 |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|ISAF 30.50(b)(2)         SAFETY EQUIPMENT FAILUR|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SOURCE HOLDER FRAME AND CONTROL SYSTEM DAMAGED                               |

|                                                                              |

|                                                                              |

| On 6/21/03 at approximately 1150 CST,  a source holder frame that houses a 1 |

| Curie Am-241 source was damaged.  The licensee, Nucor Steel, uses the source |

| to determine steel strip thickness.  The source holder and the source are    |

| intact and the source is retracted into the safe position.  Only the metal   |

| frame that supports the source holder and the source control system was      |

| damaged.  The manufacturer, Radiometric, has been contacted to repair the    |

| frame.  The source is exposed using an air signal which is currently locked  |

| and tagged out by the licensee.                                              |

|                                                                              |

| Informed R3DO (Riemer) and NMSS EO (Reamer).                                 |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39955       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 06/22/2003|

|    UNIT:  [] [3] []                 STATE:  NY |NOTIFICATION TIME: 21:18[EDT]|

|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        06/22/2003|

+------------------------------------------------+EVENT TIME:        17:42[EDT]|

| NRC NOTIFIED BY:  ANDY BARTLIK                 |LAST UPDATE DATE:  06/22/2003|

|  HQ OPS OFFICER:  BILL GOTT                    +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |KENNETH JENISON      R1      |

|10 CFR SECTION:                                 |RICHARD WESSMAN      IRO     |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|HERB BERKOW          NRR     |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|3     A/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC REACTOR TRIP WITH AFW ACTUATION                                    |

|                                                                              |

| The following information was obtained from the licensee via facsimile:      |

|                                                                              |

| "In order to support maintenance on feeder W-98 [Distribution Line], 345 KV  |

| Circuit Breaker #3 was opened.  Indian Point 3 remained in service utilizing |

| the feed via 345 KV Circuit Breaker #1.  After Con Edison completed          |

| maintenance on W-98, at 17:42 [EDT] an attempt was made to close 345 KV      |

| Circuit Breaker #3.  While attempting to close 345 KV Circuit Breaker #3, a  |

| fault occurred, resulting in an automatic Generator Trip, Reactor Trip and   |

| Turbine Trip.                                                                |

|                                                                              |

| "Automatic Safety Features operated as required, with all control rods       |

| inserting.                                                                   |

|                                                                              |

| "Decay heat is being removed by the Steam Generators, with make up provided  |

| by Auxiliary Feedwater with steam being relieved to the Main Condenser.      |

|                                                                              |

| "Off site power feeders remained available.  Off Site power is currently     |

| stable and providing power to all 480 Volt Safeguards Buses.  Automatic      |

| start and operation of the Emergency Diesel 'G' was not required."           |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

+------------------------------------------------------------------------------+



                    