Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for May 22, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           05/21/2003 - 05/22/2003



                              ** EVENT NUMBERS **



39754  39853  39869  39870  39871  39872  39873  39874  39875  



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39754       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 04/13/2003|

|    UNIT:  [1] [] []                 STATE:  TX |NOTIFICATION TIME: 19:06[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        04/13/2003|

+------------------------------------------------+EVENT TIME:        16:56[CDT]|

| NRC NOTIFIED BY:  RON GIBBS                    |LAST UPDATE DATE:  05/21/2003|

|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |DAVID LOVELESS       R4      |

|10 CFR SECTION:                                 |                             |

|ADEG 50.72(b)(3)(ii)(A)  DEGRADED CONDITION     |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| REACTOR VESSEL BOTTOM HEAD DEGRADED CONDITION                                |

|                                                                              |

| "On 4/12/2003, during the Unit 1 11th (1RE11) refueling outage, an           |

| inspection was performed of the vessel bottom head. This bare metal          |

| inspection identified a potential leak indication at the head to penetration |

| interface for Bottom Mounted Instrumentation (BMI) penetrations 1 and 46.    |

| There was a small amount of residue around the outer circumference of the    |

| BMI penetrations. No wastage was observed. Samples of the residue were taken |

| and the area was cleaned with demineralized water. Chemical sample results   |

| available as of 1300 on 4/13/2003 are not conclusive; however, they have     |

| confirmed that the residue found at the Penetration 46 contains boron,       |

| indicating that this could be an RCS leak. The residue removed from          |

| Penetration 1 was characterized as 'gummy' and its composition is still      |

| under investigation. Additional exams are planned to confirm the likely      |

| origin of the residue and to determine the scope of any repairs. There has   |

| been no indication of RCS leakage observed at the BMI penetrations during    |

| previous operational cycles. This notification is being made in accordance   |

| with 10 CFR 50.72(b)(3)(ii)(A)."                                             |

|                                                                              |

| Unit 1 will remain in mode 5 until appropriate corrective actions are        |

| identified.  The licensee informed the NRC resident inspector.               |

|                                                                              |

| * * * * UPDATE 1151 EDT 04/18/03 FROM WAYNE HARRISON TO MIKE RIPLEY  * * *   |

|                                                                              |

| "STP Nuclear Operating Co. will be making a press release [at 12:00 pm       |

| 04/18/03] concerning the indications found on the Bottom Mounted             |

| Instrumentation penetrations on Unit 1. The release is being coordinated     |

| with NRC Region IV.                                                          |

|                                                                              |

| "STP has notified or will be notifying various federal, state and local      |

| agencies, including FEMA, the governors office, Matagorda County, Bay City.  |

| City of Palacios, state representatives and state senators, US               |

| representatives and US Senators."                                            |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

|                                                                              |

| Notified R4DO (C. Johnson), HQ PAO (W. Beecher)                              |

|                                                                              |

| *** UPDATE AT 1745 EDT ON 05/21/03 FROM WAYNE HARRISON TO ARLON COSTA ***    |

|                                                                              |

| "STP Nuclear Operating Co. expects to make a press release on 5/22/2003      |

| concerning the indications found on the Bottom Mounted Instrumentation       |

| penetrations on Unit 1.  NRC Region IV has been advised of the planned press |

| release.  STPNOC will also be sharing the press release with various local   |

| and state government agencies.                                               |

|                                                                              |

| "The draft release is attached.                                              |

|                                                                              |

| "NRC was notified of the leakage per 10CFR50.72 on 4/13/2003 (EN# 39754).    |

|                                                                              |

| "NRC was notified of a press release describing the leakage on 4/18/2003     |

| (EN#39754 update)."                                                          |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

|                                                                              |

| Notified HQ PAO (W. Beecher) and R4DO(T. Pruett).                            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Fuel Cycle Facility                              |Event Number:   39853       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 05/16/2003|

|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 10:04[EDT]|

| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/15/2003|

|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        14:00[EDT]|

|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  05/21/2003|

|    CITY:  PIKETON                  REGION:  3  +-----------------------------+

|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |

|LICENSE#:  GDP-2                 AGREEMENT:  N  |SONIA BURGESS        R3      |

|  DOCKET:  0707002                              |TOM ESSIG            NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  MCCLEERY                     |                             |

|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|QSAF 72.75(c)(2)         SAFETY EQUIP DISABLED/F|                             |

|NONR                     OTHER UNSPEC REQMNT    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SAFETY SYSTEM ACTUATION                                                      |

|                                                                              |

| On 5/15/03 @1400 during pigtail disconnect, a small amount of particulate    |

| fell from the pigtail. This particulate began to smoke resulting in a see    |

| and flee.  During the see and flee the gas release alarm was activated.  The |

| alarm resulted in the actuation of a "Q" Safety system while in applicable   |

| mode (mode III).  The PSS Responded to the see and flee.  The affected       |

| cylinder was made inoperable.  No spread of contamination outside already    |

| posted area.   Air sampling results are less than MDA.                       |

|                                                                              |

| The NRC Resident Inspector was notified.                                     |

|                                                                              |

| * * * UPDATE AT 23:46 EDT ON 5/20/03 FROM McCLEERY TO CROUCH * * *           |

|                                                                              |

| The following update was received from the regulatee via facsimile:          |

|                                                                              |

| "5/20/05: As requested, this is additional information to clarify some       |

| questions in the initial report of PTS-2003-011.  Mode III (Cylinder/Pigtail |

| Operations) includes but is not limited to pigtail                           |

| connection/disconnections, roll/tilt and valve clarity checks; steam valves  |

| closed, cylinder valve or safety valve may or may not be closed.  MDA is     |

| minimum detectable activity.  The initial report should have been marked as  |

| Other Non-CFR Requirements in place of (c)(2) safety equipment failure.      |

|                                                                              |

| Additionally, during the investigation of the event it was determined the    |

| cylinder safety valve air supply was removed prior to the see and flee.      |

| This condition is reportable under 76.120 (c)(2)(ii) [and] 76.120 (d)(2).    |

| The equipment is required by Technical Safety Requirements (TSR) to be       |

| available and operable to perform the required safety function, while the    |

| autoclave is operating in mode III (cylinder/ pigtail operations).           |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Fuel Cycle Facility                              |Event Number:   39869       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 05/20/2003|

|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 23:46[EDT]|

| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/20/2003|

|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        09:30[EDT]|

|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  05/21/2003|

|    CITY:  PIKETON                  REGION:  3  +-----------------------------+

|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |

|LICENSE#:  GDP-2                 AGREEMENT:  N  |ANNE MARIE STONE     R3      |

|  DOCKET:  0707002                              |JOHN HICKEY          NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  JIM McCLEERY                 |                             |

|  HQ OPS OFFICER:  HOWIE CROUCH                 |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|OSAF 76.120(c)(2)        SAFETY EQUIPMENT FAILUR|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SAFETY EQUIPMENT FAILURE                                                     |

|                                                                              |

| The following information was obtained from the regulatee via facsimile:     |

|                                                                              |

| "05/20/03 at 0930 hrs. following the investigation into circumstances        |

| surrounding NRC Event #39853 (PTS-2003-011 update #1), the Plant Shift       |

| Superintendent's (PSS) office was notified that the air supply line to the   |

| parent cylinder safety valves had been disconnected during applicable TSR    |

| mode III (Cylinder/Pigtail Operations) on multiple occasions in both the     |

| X-343 and X-344 facilities.  Discussions with facility management and        |

| operating personnel indicate the air supply line was disconnected in         |

| preparation for sampling operations.  This condition is reportable under     |

| 76.120 (c)(2)(ii) and 76.120 (d)(2).  The equipment is required by Technical |

| Safety Requirements (TSR) to be available and operable and either should     |

| have been operating or have operated on demand.                              |

|                                                                              |

| "The PSS directed an extent of condition be performed for cylinder           |

| operations in X-342, X-343, X-344 and X-326 withdrawal station.  The result  |

| of the extent of condition placed the X-343 sample autoclaves in mode VII    |

| (shutdown) and removed from service until affected procedures can be         |

| changed, the X-344 autoclaves remain operable, the X-342 autoclaves remains  |

| inoperable, and the X-326 withdrawal station remains operable."              |

|                                                                              |

| The regulatee has notified the NRC Resident Inspector.                       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Fuel Cycle Facility                              |Event Number:   39870       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 05/21/2003|

|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 00:08[EDT]|

| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/20/2003|

|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        19:15[CDT]|

|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  05/21/2003|

|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+

|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |

|LICENSE#:  GDP-1                 AGREEMENT:  Y  |ANNE MARIE STONE     R3      |

|  DOCKET:  0707001                              |JOHN HICKEY          NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  C. PITTMAN                   |                             |

|  HQ OPS OFFICER:  HOWIE CROUCH                 |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NBNL                     RESPONSE-BULLETIN      |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| CRITICALITY CONTROL 24-HOUR REPORT (BULLETIN 91-01)                          |

|                                                                              |

| The following information was received from the regulatee via facsimile :    |

|                                                                              |

| "At 1915 on 5/20/03, the Plant Shift Superintendent (PSS) was notified that  |

| some removed process gas equipment item groups in C-720 have not received    |

| proper independent mass verification in violation of NCSA GEN-010.  The      |

| group mass is required to be independently verified to be within always safe |

| mass limits.  This is done by independently verifying the equipment item     |

| mass is correctly copied onto the grouping sheet.  An entry was discovered   |

| on the grouping sheet in which the mass on the equipment was 0 [zero]        |

| pounds, however the GEN-010 tag on the equipment item indicated a mass of    |

| 284 pounds of uranium at 1.38% enrichment.  Additionally, several equipment  |

| items were tagged with GEN-010 tags that had information lined out and       |

| corrected, appearing to violate the independent verification of the          |

| equipment item mass, on the tag.  This information was then subsequently     |

| used for grouping purposes on the equipment grouping sheet. This is a legacy |

| issue, as the dates on the tags are from the 97-98 timeframe.                |

|                                                                              |

| "SAFETY SIGNIFICANCE OF EVENTS:                                              |

|                                                                              |

| "Double contingency was not maintained because the independent verification  |

| of mass has not been performed. However, the policy for the shop is to only  |

| allow items which have been fully decontaminated into the shop, which gives  |

| high confidence that less than a safe mass is present.                       |

|                                                                              |

| "POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO(S) OF HOW           |

| CRITICALITY COULD OCCUR):                                                    |

|                                                                              |

| "In order for a criticality to be possible, greater than a critical mass of  |

| uranium must be accumulated [and] then become moderated.                     |

|                                                                              |

| "CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.):    |

|                                                                              |

| "Double contingency is maintained by implementing two controls on mass.      |

|                                                                              |

| "ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS    |

| LIMIT AND %  WORST CASE CRITICAL MASS):                                      |

|                                                                              |

| "Less than an always safe mass of uranium.                                   |

|                                                                              |

| "NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION  |

| OF THE FAILURES OR DEFICIENCIES:                                             |

|                                                                              |

| "The first leg of double contingency is based on mass.  NCSA GEN-010         |

| requires that the total uranium mass of grouped items be verified less than  |

| the UH [Uncomplicated Handling] mass limit and documented.  The mass of an   |

| equipment item was incorrectly copied onto the grouping sheet.  However, the |

| listed mass for the item is UH at the listed enrichment.  In addition, other |

| items in the group have tags, which indicate no visible contamination but    |

| have been updated and only have one signature.  This mass was then used in   |

| the grouping.  The control was violated, however the parameter has been      |

| maintained.                                                                  |

|                                                                              |

| "The second leg of double contingency is based on mass.  NCSA GEN-010        |

| requires that the total uranium mass of grouped items be independently       |

| verified less than the UH mass limit and documented in accordance with       |

| CP2-PO-FO1031 [a facility procedure].  The independent verification was      |

| incorrectly performed; therefore, this control was violated.  Since there    |

| are two controls on one parameter, double contingency was not maintained.    |

|                                                                              |

| "Since double contingency is based on two controls on one parameter, and a   |

| control was violated, double contingency was not maintained.                 |

|                                                                              |

| "CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEMS AND WHEN EACH WAS              |

| IMPLEMENTED:                                                                 |

|                                                                              |

| "Ensure each item in the group is properly tagged according to CP2-CO-CN2030 |

| [a facility procedure].  Properly group and document each equipment item     |

| according to CP2-CO-CN2030.  Upon completion of the above corrective         |

| actions, the exclusion zone and postings may be removed."                    |

|                                                                              |

| The regulatee has notified the NRC Resident Inspector.                       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39871       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PALO VERDE               REGION:  4  |NOTIFICATION DATE: 05/21/2003|

|    UNIT:  [1] [2] [3]               STATE:  AZ |NOTIFICATION TIME: 09:15[EDT]|

|   RXTYPE: [1] CE,[2] CE,[3] CE                 |EVENT DATE:        05/21/2003|

+------------------------------------------------+EVENT TIME:        02:20[MST]|

| NRC NOTIFIED BY:  COSENZA                      |LAST UPDATE DATE:  05/21/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |TROY PRUETT          R4      |

|10 CFR SECTION:                                 |                             |

|NINF                     INFORMATION ONLY       |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       98       Power Operation  |98       Power Operation  |

|2     N          Y       98       Power Operation  |98       Power Operation  |

|3     N          Y       98       Power Operation  |98       Power Operation  |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| FAILURE OF THE SECURITY FORCES HAND HELD RADIOS                              |

|                                                                              |

| Security at the site had a partial loss of their radio system.  Their Bay    |

| station and telephone communications systems were up, but the hand held      |

| radios could not transmit out.  These radios, however could receive.  This   |

| problem has occurred in the past.   Their communications people were able to |

| reboot the system and go back to the secondary and returned the radios back  |

| to service.  There was no evidence that equipment had been tampered with.    |

|                                                                              |

| The NRC Resident will be notified.                                           |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39872       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 05/21/2003|

|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 11:31[EDT]|

|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        05/21/2003|

+------------------------------------------------+EVENT TIME:        04:18[CDT]|

| NRC NOTIFIED BY:  DENNIS FRANCIS               |LAST UPDATE DATE:  05/21/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ANNE MARIE STONE     R3      |

|10 CFR SECTION:                                 |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          Y       85       Power Operation  |85       Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ACCIDENT MITIGATION DEGRADED DUE TO PRESSURE SWITCHES OUTSIDE TECHNICAL      |

| SPECIFICATION ALLOWANCES                                                     |

|                                                                              |

| "During calibration of Dresden Unit 2 Electromatic Relief Valve/Target Rock  |

| Valve Pressure Switches, two of the five pressure switches were found        |

| outside the Technical Specification (TS) Allowable Range and outside the     |

| Analytical Limit (1.5 psig above the TS Allowable).  Setpoints for the B and |

| C Electromatic Relief Valves (ERVs) were found at 3.1 and 2.4 psig above the |

| TS allowable respectively.  The TS Bases state that four ERVs are required   |

| to accomplish the safety function for pressure mitigation.  This event is    |

| reportable because two of five ERV pressure switches were outside TS         |

| allowables, which could have prevented fulfillment of the safety function    |

| for pressure mitigation (10 CFR 50.73(a)(2)(v)].  The pressure switch        |

| setpoints have been subsequently calibrated and returned to within TS        |

| allowable values."                                                           |

|                                                                              |

| The licensee notified NRC Resident Inspector.                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Other Nuclear Material                           |Event Number:   39873       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  S.K. GEOTECHNICAL CORPORATION        |NOTIFICATION DATE: 05/21/2003|

|LICENSEE:  S.K. GEOTECHNICAL CORPORATION        |NOTIFICATION TIME: 13:06[EDT]|

|    CITY:  HELENA                   REGION:  4  |EVENT DATE:        05/21/2003|

|  COUNTY:                            STATE:  MT |EVENT TIME:        07:00[MDT]|

|LICENSE#:  25-27594-01           AGREEMENT:  N  |LAST UPDATE DATE:  05/21/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |TROY PRUETT          R4      |

|                                                |JIM WHITNEY          TAS     |

+------------------------------------------------+LARRY CAMPER         NMSS    |

| NRC NOTIFIED BY:  LOWELL KLOCKE                |                             |

|  HQ OPS OFFICER:  ARLON COSTA                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|BLO1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| STOLEN MOISTURE DENSITY GAUGE                                                |

|                                                                              |

| A Campbell Pacific Nuclear portable moisture density gauge Model MC-3,       |

| Serial Number MC 39058846 was stolen from the licensee's storage trailer.    |

| The gauge contains a cesium-americium-beryllium radioactive source (10       |

| millicuries Cs-137 and 50 millicuries Am-241/Be).  The licensee's trailer    |

| containing the stolen gauge was located at a Home Depot construction site,   |

| 1801 Custer Ave, Helena, MT 59601.  Helena City police is investigating this |

| and other thefts that occurred overnight at several trailers located at this |

| same site.                                                                   |

|                                                                              |

| The licensee contacted Region IV (M. Shaffer) and will contact the Montana   |

| Department of Health.                                                        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39874       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 05/21/2003|

|    UNIT:  [2] [3] []                STATE:  NY |NOTIFICATION TIME: 17:32[EDT]|

|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        05/21/2003|

+------------------------------------------------+EVENT TIME:        13:55[EDT]|

| NRC NOTIFIED BY:  RICHARD ALEXANDER            |LAST UPDATE DATE:  05/21/2003|

|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ANTHONY DIMITRIADIS  R1      |

|10 CFR SECTION:                                 |                             |

|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|2     N          Y       100      Power Operation  |100      Power Operation  |

|3     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOSS COMMUNICATION DUE TO MORE THAN 10% AVAILABILITY OF SIRENS               |

|                                                                              |

| "On May  21, 2003 at 1355 hours, during on site monitoring of the offsite    |

| emergency notification system, three (3) sirens out of a total of 10 in      |

| Putnam County indicated a communications failure.  The cause for the failure |

| was subsequently determined, based on information obtained by the crew, to   |

| have been attributed to communication failure due to fuse failure at the     |

| sirens.  Communication was fully restored to the affected sirens at          |

| approximately 1549 hours on May 21, 2003.  Route alerting was available      |

| during the loss of sirens.                                                   |

|                                                                              |

| "The NRC resident inspectors, State and Putnam county were notified of this  |

| event."                                                                      |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Other Nuclear Material                           |Event Number:   39875       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TERRACON CORPORATION                 |NOTIFICATION DATE: 05/21/2003|

|LICENSEE:  TERRACON CORPORATION                 |NOTIFICATION TIME: 18:08[EDT]|

|    CITY:  Raymore                  REGION:  3  |EVENT DATE:        05/21/2003|

|  COUNTY:                            STATE:  MO |EVENT TIME:             [CDT]|

|LICENSE#:  15-27070-01           AGREEMENT:  N  |LAST UPDATE DATE:  05/21/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |TROY PRUETT          R4      |

|                                                |MARK SHAFFER         R4      |

+------------------------------------------------+LARRY CAMPER         NMSS    |

| NRC NOTIFIED BY:  Bob Weber                    |ANNE MARIE STONE     R3      |

|  HQ OPS OFFICER:  MIKE RIPLEY                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NONR                     OTHER UNSPEC REQMNT    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| DAMAGED MOISTURE DENSITY GUAGE                                               |

|                                                                              |

| A moisture density gauge owned by the licensee was damaged when it was run   |

| over at a construction site in Raymore, Missouri (Hwy. 58 at Lauris Dr.).    |

| The gauge is a Campbell Pacific model CPN1DR containing a 10 millicurie      |

| Cs-137 source and a 50 millicurie Am-241:Be source.  The gauge has been      |

| isolated and it has been determined that the sources appear intact.   The    |

| licensee is the process of retrieving the gauge for return to the            |

| manufacturer.                                                                |

|                                                                              |

| Notified R3DO (A. Stone),  R4DO (T. Pruett), R4 (Mark Shaffer), NMSS EO (L.  |

| Camper)                                                                      |

+------------------------------------------------------------------------------+





                    