Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 28, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           04/25/2003 - 04/28/2003



                              ** EVENT NUMBERS **



39780  39790  39796  39797  39799  39800  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39780       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  MARYLAND DEPT OF THE ENVIRONMENT     |NOTIFICATION DATE: 04/22/2003|

|LICENSEE:  ENGINEERING CONSULTANT SERVICES      |NOTIFICATION TIME: 11:05[EDT]|

|    CITY:  FREDERICK                REGION:  1  |EVENT DATE:        04/22/2003|

|  COUNTY:  FREDERICK                 STATE:  MD |EVENT TIME:             [EDT]|

|LICENSE#:  MD2103701             AGREEMENT:  Y  |LAST UPDATE DATE:  04/22/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |HAROLD GRAY          R1      |

|                                                |TOM ESSIG            NMSS    |

+------------------------------------------------+MATT HAHN            IAT     |

| NRC NOTIFIED BY:  ALAN JACOBSON                |                             |

|  HQ OPS OFFICER:  MIKE RIPLEY                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE                       |

|                                                                              |

| The licensee reported that upon arriving at their work site in Bethesda, MD  |

| early in the morning of 04/22/03 they discovered that their construction     |

| trailer was broken into and a moisture density gauge stolen.  The gauge is a |

| CPN Model # MC1DR, S/N MD00305503 containing 10 millicuries Cs-137 and 50    |

| millicuries Am-241:Be.  The licensee notified the Montgomery County Police   |

| (Case # B03089862).                                                          |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39790       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 04/24/2003|

|    UNIT:  [1] [2] []                STATE:  MI |NOTIFICATION TIME: 04:40[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        04/24/2003|

+------------------------------------------------+EVENT TIME:        03:48[EDT]|

| NRC NOTIFIED BY:  STUART SCHUETTPELZ           |LAST UPDATE DATE:  04/25/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          ALERT                 |MONTE PHILLIPS       R3      |

|10 CFR SECTION:                                 |JAMES LYONS          NRR     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |MICHELE EVANS        IRO     |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|CHUCK CAIN           R4      |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|CHARLIE BAGWELL      FEMA    |

|                                                |JOHN FLACH           NRC     |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     M/R        Y       100      Power Operation  |0        Hot Standby      |

|2     M/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ALERT DECLARED                                                               |

|                                                                              |

| At 0348 EDT on 4/24/03, the plant experienced an influx of fish on the       |

| intake screens for the circwater and essential service water (ESW) systems.  |

| This resulted in a loss of vacuum to Units 1 and 2 main turbines, which led  |

| operators to manually trip both reactors.  Following the trip, operators     |

| noted that ESW flow to all 4 emergency diesel generators (EDGs) was severely |

| degraded.  This resulted in the licensee declaring all 4 EDG's inoperable.   |

| An alert was declared at 0348 EDT, and the NRC entered Monitoring Mode at    |

| 0506 EDT.                                                                    |

|                                                                              |

| * * * UPDATE AT 0600 ON 4/24/03 FROM LICENSEE TO H. CROUCH * * *             |

|                                                                              |

| All EDG's have adequate flow to be used in an emergency, but remain          |

| inoperable.                                                                  |

|                                                                              |

| The licensee is assessing damage to intake screens and strainers in the ESW  |

| system, and manually backwashing ESW screens.                                |

|                                                                              |

| * * * UPDATE AT 0718 ON 4/24/03 FROM DEAN BRUCK TO E. THOMAS * * *           |

|                                                                              |

| The licensee made a 4-hour ENS notification under 10 CFR 50.72(b)(2)(iv)(B)  |

| to inform the NRC of the manual reactor trips inserted on Units 1 and 2 at   |

| 0328 and 0329 on 4/24/03 for the reasons listed above.  Post-trip response   |

| of the plant was normal.  Main Steam Isolation Valves were manually closed   |

| on both units due to lowering Reactor Coolant System temperature and         |

| lowering vacuum.  Both units remain in Mode 3.                               |

|                                                                              |

| * * * UPDATE AT 1020 ON 4/24/03 FROM TODD CASPER TO E. THOMAS * * *          |

|                                                                              |

| The licensee made an 8-hour ENS notification under 10 CFR 50.72(b)(3)(iv)(A) |

| to inform the NRC of the Auxiliary Feedwater System (AFW) actuations in      |

| Units 1 and 2 following the reactor trips.  The heat removal path for both   |

| units is via AFW to the steam generator pressure operated relief valves.     |

|                                                                              |

| * * * UPDATE AT 0532 ON 4/25/03 FROM R3 IRC TO E. THOMAS * * *               |

|                                                                              |

| The licensee terminated the Alert at 0521 EDT.  The Alert was terminated     |

| based on having one train of ESW and one EDG declared OPERABLE for each      |

| Unit.  The NRC exited the Monitoring Mode of normal operations at 0532 EDT.  |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39796       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 04/25/2003|

|    UNIT:  [1] [2] []                STATE:  MI |NOTIFICATION TIME: 09:58[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        04/24/2003|

+------------------------------------------------+EVENT TIME:        14:17[EDT]|

| NRC NOTIFIED BY:  LEE BUSH                     |LAST UPDATE DATE:  04/25/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MONTE PHILLIPS       R3      |

|10 CFR SECTION:                                 |                             |

|HFIT 26.73               FITNESS FOR DUTY       |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Hot Shutdown     |0        Hot Shutdown     |

|2     N          N       0        Hot Shutdown     |0        Hot Shutdown     |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| FITNESS FOR DUTY                                                             |

|                                                                              |

| A contract employee was determined to be under the influence of marijuana    |

| during a monitor result drug test.  The employee's access to the plant has   |

| been permanently terminated.  Contact the HOO for additional details.        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39797       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 04/25/2003|

|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 10:24[EDT]|

|   RXTYPE: [1] GE-4                             |EVENT DATE:        03/29/2003|

+------------------------------------------------+EVENT TIME:        01:14[CDT]|

| NRC NOTIFIED BY:  COY L. BLAIR                 |LAST UPDATE DATE:  04/25/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHUCK CAIN           R4      |

|10 CFR SECTION:                                 |                             |

|AINV 50.73(a)(1)         INVALID SPECIF SYSTEM A|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Refueling        |0        Refueling        |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| 60-DAY OPTIONAL REPORT FOR INVALID SPECIFIED SYSTEM ACTUATION                |

|                                                                              |

| The following information was obtained from the licensee via facsimile:      |

|                                                                              |

| "THIS IS BEING REPORTED PER 10 CFR 50.73(a)(2)(iv)(A).                       |

|                                                                              |

| "The following systems inadvertently actuated:                               |

|                                                                              |

| "Core Spray A                                                                |

| "Core Spray B                                                                |

| "#2 Diesel Generator started and came to speed                               |

|                                                                              |

| "Core Spray A and B were complete actuations.                                |

|                                                                              |

| "#2 Diesel Generator was a partial actuation since it did not load.  There   |

| was no loss of offsite power or requirement to load.                         |

|                                                                              |

| "Affected equipment started and functioned successfully."                    |

|                                                                              |

| The cause of the actuation was human error when the operator performing a    |

| Reactor Protection System surveillance test mechanically actuated the wrong  |

| relay.  The reactor was in refueling and flooded-up at the time of the core  |

| spray actuation.  There was a minor change in skimmer surge tank level       |

| before Operations personnel were able to manually isolate core spray.        |

|                                                                              |

| The licensee still has a Significant Condition Report (SCR) open that should |

| address ways to minimize re-occurrence.                                      |

|                                                                              |

| The licensee will be notifying the NRC Resident Inspector.                   |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39799       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: ROBINSON                 REGION:  2  |NOTIFICATION DATE: 04/26/2003|

|    UNIT:  [2] [] []                 STATE:  SC |NOTIFICATION TIME: 18:23[EDT]|

|   RXTYPE: [2] W-3-LP                           |EVENT DATE:        04/26/2003|

+------------------------------------------------+EVENT TIME:        17:46[EDT]|

| NRC NOTIFIED BY:  EAYRES                       |LAST UPDATE DATE:  04/26/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          UNUSUAL EVENT         |MIKE ERNSTES         R2      |

|10 CFR SECTION:                                 |JAMES LYONS          NRR     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |MICHELE EVANS        IRO     |

|                                                |DAN SULLIVAN         FEMA    |

|                                                |ALTERNATE SITE               |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| NOUE DECLARED DUE TO FIRE IN THE OWNER PROTECTED AREA LASTING MORE THAN 10   |

| MINS.                                                                        |

|                                                                              |

| The licensee declared a NOUE at 1803 due to a fire in the owner protected    |

| area on the motor of the  "B" circulating water pump at the intake that      |

| lasted for more than 10 minutes.  There are a total of three pumps and two   |

| are now operable.  The smoking fire (no flames) was extinguished at 1823     |

| with no assistance from offsite.  There were no injuries or damage to the    |

| plant.  The licensee will not issue a press release.                         |

|                                                                              |

| The licensee notified the State of South Carolina, Darling , Lee, and        |

| Chesterfield counties.                                                       |

|                                                                              |

| The NRC Resident Inspector was notified.                                     |

|                                                                              |

| *****UPDATE ON 4/26/03 AT 19:30 FROM EAYRES TO LAURA*****                    |

|                                                                              |

| The NOUE was terminated at 19:23. The electrical fire is out and there was   |

| no impact on continued plant operation.                                      |

|                                                                              |

| Notified R2DO (ERNSTES), DIRO (EVANS), NRR (LYONS), NRC ALTERNATE SITE, FEMA |

| (EACHES)                                                                     |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Fuel Cycle Facility                              |Event Number:   39800       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 04/27/2003|

|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 18:05[EDT]|

| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        04/26/2003|

|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        22:06[CDT]|

|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  04/27/2003|

|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+

|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |

|LICENSE#:  GDP-1                 AGREEMENT:  Y  |MONTE PHILLIPS       R3      |

|  DOCKET:  0707001                              |DANIEL GILLEN        NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  SKAGGS                       |                             |

|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|OSAF 76.120(c)(2)        SAFETY EQUIPMENT FAILUR|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| PLANT HAD A SAFETY EQUIPMENT FAILURE                                         |

|                                                                              |

| At 2208 CST, on 4-26-03 the Plant Shift Superintendent (PSS) was notified    |

| that a UF6 Release Detection System smoke detector for the No. 3 Normetex    |

| Pump in C-315 had fired.   Operators responded and found no indications of a |

| UF6 release.   The No. 3 Normetex Pump was in TSR 2.3.1 Mode 4, "Not In Use" |

| at the time the smoke detector alarmed.   Operators then attempted to reset  |

| the smoke detector and a system trouble alarm was received.   The trouble    |

| alarm would not reset and attempts to test fire the smoke detectors for the  |

| Normetex Pumps was unsuccessful.   At the time of this incident, the C-315   |

| No.1 and No. 2 Normetex Pumps were in an operational mode in which the UF6   |

| Release Detection System was required to be operable, TSR 2.3.4.3 Mode 2,    |

| "Withdrawal".   The PSS declared the system inoperable and TSR LCO 2.3.4.3   |

| actions were implemented to establish a smoke watch and place the Normetex   |

| pumps in Mode 3, "Standby".   The failed smoke detector was replaced, post   |

| maintenance testing completed and the system was declared operable at 0053   |

| CST on 4-27-03.                                                              |

|                                                                              |

| The event is reportable as a 24 hour event, as required by 10 CFR            |

| 76.120(c)(2)(l); "An event in which equipment is disabled or fails to        |

| function as designed when the equipment is required by a TSR to prevent      |

| releases, prevent exposures to radiation and radioactive materials exceeding |

| specified limits, mitigate the consequences of an accident, or restore this  |

| facility to a pre-established safe condition after an accident."  The        |

| equipment was required by TSR to be available and operable and no redundant  |

| equipment was available to perform the required safety function.             |

|                                                                              |

| The NRC Resident Inspector has been notified of this event.                  |

+------------------------------------------------------------------------------+





                    