Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 22, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           04/21/2003 - 04/22/2003



                              ** EVENT NUMBERS **



39763  39777  39778  39779  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39763       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  MA RADIATION CONTROL PROGRAM         |NOTIFICATION DATE: 04/16/2003|

|LICENSEE:  AEA TECHNOLOGY QSA                   |NOTIFICATION TIME: 10:07[EDT]|

|    CITY:  BURLINGTON               REGION:  1  |EVENT DATE:        04/15/2003|

|  COUNTY:                            STATE:  MA |EVENT TIME:             [EDT]|

|LICENSE#:  12-8361               AGREEMENT:  Y  |LAST UPDATE DATE:  04/16/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |DAVID SILK           R1      |

|                                                |THOMAS ESSIG         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  BRUCE PACKARD                |                             |

|  HQ OPS OFFICER:  RICH LAURA                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MASSACHUSETTS AGREEMENT STATE REPORT ON SHIPPING PACKAGE RADIOLOGICAL ISSUE  |

|                                                                              |

| "On April 15, 2003, a Yellow-III Package containing 30 millicuries (1.1 Gbq) |

| of Co-60 measured 400 millirem/hr on the surface. The Shipper was AEA        |

| Technology QSA GMBH, Giesilweg 1, D-38110 Braunschweig, Germany. The         |

| carriers included Federal Express Freight and Ground Control. Immediate      |

| reporting requirements means investigation is not complete at the time of    |

| report."                                                                     |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39777       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: FITZPATRICK              REGION:  1  |NOTIFICATION DATE: 04/21/2003|

|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 12:35[EDT]|

|   RXTYPE: [1] GE-4                             |EVENT DATE:        04/21/2003|

+------------------------------------------------+EVENT TIME:        11:40[EDT]|

| NRC NOTIFIED BY:  A. HALLIDAY                  |LAST UPDATE DATE:  04/21/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |HAROLD GRAY          R1      |

|10 CFR SECTION:                                 |                             |

|DDDD 73.71(b)(1)         SAFEGUARDS REPORTS     |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| DISCOVERY OF SAFEGUARDS INFORMATION.                                         |

|                                                                              |

| IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY.                        |

|                                                                              |

| THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED OF THIS EVENT BY THE LICENSEE.   |

|                                                                              |

| CONTACT THE HOO FOR FURTHER DETAILS.                                         |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39778       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: GINNA                    REGION:  1  |NOTIFICATION DATE: 04/21/2003|

|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 15:32[EDT]|

|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        04/21/2003|

+------------------------------------------------+EVENT TIME:        07:30[EDT]|

| NRC NOTIFIED BY:  MIKE MICKLOW                 |LAST UPDATE DATE:  04/21/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |HAROLD GRAY          R1      |

|10 CFR SECTION:                                 |                             |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| EMERGENCY RESPONSE SIREN ACTUATED.                                           |

|                                                                              |

| At approximately 1430 hours EDT, control room personnel received             |

| notification that one emergency response siren may have inadvertently        |

| actuated.  At approximately 1400 hours EDT control room personnel were       |

| notified that local press and media outlets were informed of the siren       |

| malfunction.  Currently 94 of 96 sirens are operable.                        |

|                                                                              |

| The NRC Resident Inspector will notified of this event by the licensee.      |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39779       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: NINE MILE POINT          REGION:  1  |NOTIFICATION DATE: 04/21/2003|

|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 22:26[EDT]|

|   RXTYPE: [1] GE-2,[2] GE-5                    |EVENT DATE:        04/21/2003|

+------------------------------------------------+EVENT TIME:        21:17[EDT]|

| NRC NOTIFIED BY:  JOHN APRIL                   |LAST UPDATE DATE:  04/21/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |HAROLD GRAY          R1      |

|10 CFR SECTION:                                 |                             |

|ASHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       23       Power Operation  |23       Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ELECTROMATIC RELIEF VALVE FAILED TO OPEN DURING POWER ASCENSION TESTING.     |

|                                                                              |

| While performing Technical Specification required surveillance testing       |

| during power ascension per NI-ST-C2, Solenoid-Activated Pressure Relief      |

| Valves Operability and Flow Verification Test, 111 Electromatic Relief Valve |

| (ERV) failed to open as required.  111  ERV has been declared inoperable and |

| Technical Specification 3.1.5. (b)  has been entered. This Limiting          |

| Condition of Operation requires reactor coolant dome pressure be reduced to  |

| 110 psig or less within 10 hours (start time is 2117 EDT).  The cause for    |

| the failure of 111 ERV is under investigation.  The other 5 ERV's (used also |

| as ADV valves) tested satisfactorily.  Plant preparations are in progress.   |

| The electrical grid is stable and their Emergency Diesel Generators are      |

| fully operable if needed.  All Emergency Core Cooling systems (including the |

| Isolation Condenser) are fully except for 111 ERV.   The licensee notified   |

| the New York Service Commission of this event.                               |

|                                                                              |

| The NRC Resident Inspector was notified of this event by the licensee.       |

+------------------------------------------------------------------------------+



                    

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021