Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 8, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           04/07/2003 - 04/08/2003



                              ** EVENT NUMBERS **



39723  39740  39741  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39723       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 04/03/2003|

|LICENSEE:  TEXAS DEPT OF TRANSPORTATION         |NOTIFICATION TIME: 12:21[EST]|

|    CITY:  ABILENE                  REGION:  4  |EVENT DATE:        03/31/2003|

|  COUNTY:                            STATE:  TX |EVENT TIME:        22:00[CST]|

|LICENSE#:  L00197                AGREEMENT:  Y  |LAST UPDATE DATE:  04/03/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |ANTHONY GODY         R4      |

|                                                |                             |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  JAMES H. OGDEN, JR           |                             |

|  HQ OPS OFFICER:  ERIC THOMAS                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ATTEMPTED THEFT OF A TROXLER GAUGE                                           |

|                                                                              |

| The Texas Department of Health reported the attempted theft of a Troxler     |

| Model 3430, (serial # unknown), on the night of 3/31/03 from a secure        |

| storage trailer at a Texas Department of Transportation construction site in |

| Abilene, TX.  Site personnel discovered the gauge in an open case on the     |

| floor of a construction trailer with its lock cut.  The trailer and its      |

| storage closet had been broken into.  The sealed source contains 8           |

| millicuries of Cs-137 and 40 millicuries of Am-241/Be.  Gauge is currently   |

| secured in a different area awaiting results of leak and serviceability      |

| tests.  An investigation is in process to determine whether other items were |

| stolen, or whether this gauge was the only target of the attempted theft.    |

|                                                                              |

| This event is technically not reportable, but was entered as an attempted    |

| theft due to three other similar incidents that did result in stolen gauges  |

| in the Dallas-Fort Worth area under similar circumstances.  The Texas        |

| Department of Transportation notified all other licensee's possessing        |

| portable nuclear gauges in the Abiline and Dallas-Fort Worth regions, along  |

| with local police and the Dallas FBI office.                                 |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39740       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: DAVIS BESSE              REGION:  3  |NOTIFICATION DATE: 04/07/2003|

|    UNIT:  [1] [] []                 STATE:  OH |NOTIFICATION TIME: 17:30[EDT]|

|   RXTYPE: [1] B&W-R-LP                         |EVENT DATE:        04/07/2003|

+------------------------------------------------+EVENT TIME:        17:00[EDT]|

| NRC NOTIFIED BY:  Art Lewis                    |LAST UPDATE DATE:  04/07/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MICHAEL PARKER       R3      |

|10 CFR SECTION:                                 |                             |

|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| UNANALYZED CONDITION                                                         |

|                                                                              |

| "During the System Health Readiness Review at Davis-Besse Nuclear Power      |

| Plant, a potential issue was discovered concerning operability of the HPI    |

| Pumps. When the HPI Pumps are taking suction from the emergency sump (i.e.,  |

| under post LOCA condition after the initial HPI injection has occurred and   |

| BWST has been depleted), it could receive particle size that could damage or |

| render the HPI pumps inoperable due to sump debris. A review of pump design  |

| and rotor dynamic analysis have determined that [the] pumps are unsuitable   |

| to take suction from a source that contains debris in the water, such as the |

| post LOCA debris (i.e., fibrous material from insulation) in the containment |

| emergency sump.                                                              |

|                                                                              |

| "The above issue is documented in Condition Report 03-01738 and is currently |

| being further investigated. Davis-Besse has determined that the above        |

| condition will be reportable under 10 CFR 50.73(a)(b)(v), Event or Condition |

| that could have prevented fulfillment of a safety function, and 10 CFR       |

| 50.73(a)(2)(ii), Degraded or Unanalyzed Condition. Although this condition   |

| was discovered during plant shutdown where HPI pumps are not required to be  |

| operable per TS 3.5.2, a subsequent review of immediate notification         |

| requirements found this condition may require an 8 hour notification via 10  |

| CFR 50.72(b)(3)(ii), i.e., that is to report a historical condition where    |

| [a] degraded/unanalyzed condition existed within 3 years. The Statements of  |

| Consideration for this reporting criterion implies such conditions if it     |

| existed within 3 years should be reported via 10 CFR 50.72(b)(3)(ii)."       |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39741       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 04/07/2003|

|    UNIT:  [] [2] []                 STATE:  MD |NOTIFICATION TIME: 22:36[EDT]|

|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        04/07/2003|

+------------------------------------------------+EVENT TIME:        22:19[EDT]|

| NRC NOTIFIED BY:  DAVE LYNCH                   |LAST UPDATE DATE:  04/08/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          UNUSUAL EVENT         |JAMES TRAPP          R1      |

|10 CFR SECTION:                                 |BRUCE BOGER          NRR     |

|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |RICHARD WESSMAN      IRO     |

|                                                |WILLIAM KANE         ET      |

|                                                |HUBERT MILLER        RI      |

|                                                |FEMA                         |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          N       0        Refueling        |0        Refueling        |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| UNUSUAL EVENT                                                                |

|                                                                              |

| At 2201, a fire started in the pressurizer doghouse.  Welding operations     |

| were ongoing in the upper part of the space, and a slag catchment device     |

| lower in the space caught fire.  The fire brigade responded to the scene.    |

| At 2219, the licensee declared an Unusual Event because of an ongoing fire   |

| in the vital area for greater than 15 minutes.  At 2234, the fire was put    |

| out by pouring water down onto the fire from above, and a reflash watch was  |

| set.  There was no damage noted to plant equipment, and no injuries to       |

| personnel.                                                                   |

|                                                                              |

| The licensee notified the NRC Resident Inspector and the surrounding         |

| counties.                                                                    |

|                                                                              |

| * * * UPDATE AT 2309 ON 4/7/03 FROM DAVE SEPANICH TO ERIC THOMAS * * *       |

|                                                                              |

| At 2300, the licensee secured from the Unusual Event.  There was no damage   |

| noted to plant components, and scaffolding will be erected to conduct        |

| further inspections.                                                         |

|                                                                              |

| The licensee notified the NRC Resident Inspector and the surrounding         |

| counties.                                                                    |

|                                                                              |

| * * * UPDATE AT 0008 ON 4/8/03 FROM MIKE KORSNICK TO ERIC THOMAS * * *       |

|                                                                              |

| The cause of the fire was slag from welding operations that fell through     |

| some fire blankets and ignited the herculite underneath.  A fire brigade     |

| member will be sent back into the space this morning to conduct further      |

| damage assessment.                                                           |

+------------------------------------------------------------------------------+





                    