Event Notification Report for March 27, 2003
                    U.S. Nuclear Regulatory Commission
                              Operations Center
                              Event Reports For
                           03/26/2003 - 03/27/2003
                              ** EVENT NUMBERS **
39685  39689  39701  39702  39703  39704  
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39685       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 03/21/2003|
|LICENSEE:  LAW ENGINEERING & ENVIRONMENTAL SERVI|NOTIFICATION TIME: 11:58[EST]|
|    CITY:  FORT WORTH               REGION:  4  |EVENT DATE:        03/21/2003|
|  COUNTY:                            STATE:  TX |EVENT TIME:        03:40[CST]|
|LICENSE#:  L05490-000            AGREEMENT:  Y  |LAST UPDATE DATE:  03/21/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLAUDE JOHNSON       R4      |
|                                                |LARRY CAMPER         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES H. OGDEN, JR.          |                             |
|  HQ OPS OFFICER:  ARLON COSTA                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT: STOLEN TROXLER MOISTURE DENSITY GAUGE                |
|                                                                              |
| "Gauge operator was working the swing shift supporting operations of         |
| construction of the Dallas Area Rapid Transit (DART) in Dallas, Texas.       |
| Enroute to company office, he stopped by his residence from 3:00 a.m. to     |
| 3:40 a.m. for breakfast.  Before departing for the storage location, 2200    |
| Gravel Drive, Fort Worth, he noted that the gauge and chain were missing     |
| from his company [Law Engineering & Environmental Services, Inc.] truck      |
| (Black Ford, F-150).  The stolen gauge is a Troxler 3411 B, Serial No.       |
| 10732, with two sealed sources: Cs-137, 8 millicuries, Serial No. 40-8208    |
| and AM-241/Be, 40 millicuries, Serial No. 46-2134.  A report of the theft    |
| was made to the White Settlement Police Department and to his supervisor,    |
| [DELETED].  The gauge, chain, and lock are completely missing from the       |
| vehicle.                                                                     |
|                                                                              |
| "Licensee notified White Settlement Police Department, and Texas Department  |
| of Health/Bureau of Radiation Control, TDH/BRC will notify NRC, INEEL,       |
| Troxler Electronic Labs, and the states of Arizona, Arkansas, Louisiana, New |
| Mexico, and Oklahoma, as well as, the country of Mexico.                     |
|                                                                              |
| "Media attention: None at this time.  Licensee is debating notifications to  |
| local media and possibly offering a reward for return of the gauge."         |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39689       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ALABAMA RADIATION CONTROL            |NOTIFICATION DATE: 03/22/2003|
|LICENSEE:  GALLET AND ASSOCIATES                |NOTIFICATION TIME: 18:44[EST]|
|    CITY:  HOMEWOOD                 REGION:  2  |EVENT DATE:        03/22/2003|
|  COUNTY:                            STATE:  AL |EVENT TIME:        09:30[CST]|
|LICENSE#:  991                   AGREEMENT:  Y  |LAST UPDATE DATE:  03/22/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CAUDLE JULIAN        R2      |
|                                                |LARRY CAMPER         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES L. MCNEES              |                             |
|  HQ OPS OFFICER:  ARLON COSTA                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT: STOLEN MOISTURE DENSITY GAUGE                        |
|                                                                              |
| "At 11:12 a.m. on Saturday March 22, 2003 James L. McNees of the Office of   |
| Radiation Control was contacted at his home by Mr. Tad Nelson of Gallet and  |
| Associates, (Alabama Radioactive Material License No. 991) and notified that |
| at approximately 10:00 a.m. this morning that a Campbell Pacific model MC-3  |
| moisture density gauge had been stolen from the back of a company pickup     |
| truck at an employee's home.  Nelson stated that the Homewood (Alabama)      |
| Police Department was currently at the location investigating.  The device   |
| contains approximately 10 mCi [millicuries] of Cs-137 and 40 mCi             |
| [millicuries] of Am-241.  Nelson further stated that the shipping container  |
| housing the device was locked, as was the control mechanism on the device,   |
| and that the thief(s) reportedly obtained the device by cutting the chain by |
| which the shipping container was locked to the bed of the truck.             |
|                                                                              |
| "Alabama Emergency Management Agency was notified at 11:28 a.m., who [in     |
| turn] alerted other civil authorities in the Jefferson County area.  The     |
| principal concern being that once the thief discovers that the stolen device |
| has little value at sale, and is hazardous, that it will be abandoned.       |
|                                                                              |
| "Mr. Nelson agreed that if the device was not recovered by this afternoon    |
| that a press release should be made.  At 5:00 p.m. today, March 22, 2003,    |
| the writer was informed by Mr. Nelson that the device had not been           |
| recovered.  Both agreed that Gallet and Associates should forward the        |
| attached press release to local Jefferson County media outlets.              |
|                                                                              |
| The Licensee, Gullet & Associates, issued the following Press Release on     |
| March 22, 2003:                                                              |
|                                                                              |
| "Around or before 9:30 on March 22, 2003, a moisture-density gauge           |
| containing sealed sources of radioactive material was stolen from its case   |
| locked to a truck owned by Gallet & Associates, Inc. of Birmingham, Alabama. |
| The truck was parked at a home in the Edgewood community of Homewood,        |
| Alabama near the Palisades Shopping Center.  The Homewood Police Department  |
| was notified and is continuing their investigation.                          |
|                                                                              |
| "The Attached is a sketch of the gauge stolen.  Labels indicating the device |
| is radioactive should be visible on the gauge itself.  Normally the          |
| radioactive sealed source is locked in a safe position.  The device does not |
| pose a health hazard as long as it is not tampered with or handled by        |
| untrained individuals.  Please notify the Homewood Police Department at      |
| (205) 877-8637, Gallet & Associates, Inc. at (205) 942-1289, the Alabama     |
| Division of Radiation Control at 1-800-582-1866, or your local police        |
| department if found.                                                         |
|                                                                              |
| "Since the device and sale of such is regulated it therefore has no resale   |
| value and can only be used to determine the moisture content and density of  |
| soils by licensed, qualified personnel.                                      |
|                                                                              |
| "A reward is offered for the recovery or information leading to the recovery |
| of the device."                                                              |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39701       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/26/2003|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 00:30[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/25/2003|
+------------------------------------------------+EVENT TIME:        23:58[EST]|
| NRC NOTIFIED BY:  ROBERT BOESCH                |LAST UPDATE DATE:  03/26/2003|
|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |PAMELA HENDERSON     R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION OF MEDICAL CONDITION                                    |
|                                                                              |
| "On 3/25/03 at 23:45 [EST] the Main Control Room was notified that an        |
| individual with a medical condition (believed to be a kidney stone) needed   |
| to be transported to the hospital by ambulance.  An ambulance was dispatched |
| to the site.   The individual was not contaminated.   The individual was     |
| transported to a local hospital for treatment.                               |
|                                                                              |
| "The Pennsylvania Emergency Management Agency was notified at 23:58 [EST].   |
| Due to notification to another government agency, this event is reportable   |
| under 10CFR50.72(b)(2)(xi)."                                                 |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39702       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 03/26/2003|
|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 06:04[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        03/26/2003|
+------------------------------------------------+EVENT TIME:        02:45[CST]|
| NRC NOTIFIED BY:  JOE BENNET                   |LAST UPDATE DATE:  03/26/2003|
|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |RUDOLPH BERNHARD     R2      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     M/R        Y       61       Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SHUTDOWN REQUIRED BY TECHNICAL SPECIFICATIONS                                |
|                                                                              |
| "On 3/26/03 at 02:45 [CST], Unit 2 experienced a trip of the 2B              |
| Recirculation system variable frequency drive (VFD).  The 2A VFD had tripped |
| earlier in the shift.  This resulted in entry into Technical Specification   |
| 3.4.1 .B, which requires the plant to be placed in Mode 3 within 12 hours.   |
| The unit was manually scrammed at this time in accordance with plant         |
| procedures.                                                                  |
|                                                                              |
| "This event is reportable within 4 hours per 10CFR 50.72 (b)(2)(i) as 'The   |
| initiation of any nuclear plant shutdown required by the plant's Technical   |
| Specifications'.  It is also reportable per 10CFR 50.72(b)(3)(iv)(A) and     |
| 10CFR 50.73(a)(2)(i)(A) and (iv)(B)."                                        |
|                                                                              |
| The cause of the Recirculation System VFD is being investigated.  The        |
| licensee notified the NRC Resident Inspector.                                |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   39703       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  DOYLESTOWN HOSPITAL                  |NOTIFICATION DATE: 03/26/2003|
|LICENSEE:  DOYLESTOWN HOSPITAL                  |NOTIFICATION TIME: 11:10[EST]|
|    CITY:  DOYLESTOWN               REGION:  1  |EVENT DATE:        03/25/2003|
|  COUNTY:                            STATE:  PA |EVENT TIME:        09:00[EST]|
|LICENSE#:  37-13234-01           AGREEMENT:  N  |LAST UPDATE DATE:  03/26/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |PAMELA HENDERSON     R1      |
|                                                |TOM ESSIG            NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  NUNNO                        |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|LDIF 35.3045(a)(1)       DOSE <> PRESCRIBED DOSA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MEDICAL EVENT WHICH INVOLVED EXCEEDING THE PRESCRIBED DOSE TO A PATIENT      |
|                                                                              |
| During a procedure using a Galileo 3 IVB made by Guidant, the company        |
| trainer was demonstrating how to conduct the procedure.  A "hot" (wire       |
| containing approximately 100 millicuries of P-32)  wire was to be inserted   |
| into the patient's coronary vessel, but prior to this a dummy wire was to be |
| inserted.  The dummy wire was inserted but not all the way.  It was removed  |
| and then the "hot" wire was inserted to the same position and then removed.  |
| It was then realized that it was not fully inserted, so they reinserted it   |
| to the full position realizing that the patient would get more that the      |
| prescribed dose of 2,000 rads (actual dose received was 2,833 rads or 41%    |
| more than the prescribed dose), but the treatment was needed by the patient. |
| There would be no adverse affects to the patient and both the patient and    |
| prescribing physician were notified.                                         |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39704       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 03/26/2003|
|    UNIT:  [1] [] []                 STATE:  TN |NOTIFICATION TIME: 11:16[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/26/2003|
+------------------------------------------------+EVENT TIME:        10:12[EST]|
| NRC NOTIFIED BY:  MICHAEL HOWARD               |LAST UPDATE DATE:  03/26/2003|
|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |RUDOLPH BERNHARD     R2      |
|10 CFR SECTION:                                 |                             |
|ADEG 50.72(b)(3)(ii)(A)  DEGRADED CONDITION     |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling Shutdow|0        Refueling Shutdow|
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR VESSEL HEAD DEGRADED CONDITION                                       |
|                                                                              |
| "During the unit 1 cycle 12 refueling and steam generator replacement        |
| outage, an inspection was performed of the vessel head in accordance with    |
| NRC Order EA-03-009.  This bare metal inspection identified a potential leak |
| indication at the head to penetration interface for CRDM (Control Rod Drive  |
| Mechanism) penetration #3.  On March 26, 2003, at approximately 1012 hours   |
| EST, it was decided that the chemical samples have confirmed that the        |
| residue found at this interface contains boron, iron, and zinc, indicating   |
| that this was an RCS leak.  This leak is most likely from a through wall     |
| crack in the RCS pressure boundary at the CRDM interface.  Volumetric exams  |
| are planned to confirm the crack and to determine the scope of any repairs.  |
| In accordance with the Order, a 100% volumetric inspection is being prepared |
| for this outage.  Prior to this identification, this unit was rated as a     |
| 'low susceptibility category.'  There had been no indication of RCS leakage  |
| during the previous cycle's operation.  This notification is being made in   |
| accordance with 10 CFR 50.72(b)(3)(ii)(A)."                                  |
|                                                                              |
| The licensee has notified the NRC Resident Inspector.                        |
+------------------------------------------------------------------------------+              