Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for March 17, 2003






                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           03/14/2003 - 03/17/2003



                              ** EVENT NUMBERS **



38513  39631  39660  39663  39670  39672  39673  





+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   38513       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 11/23/2001|

|    UNIT:  [1] [] []                 STATE:  FL |NOTIFICATION TIME: 12:30[EST]|

|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        11/23/2001|

+------------------------------------------------+EVENT TIME:        12:10[EST]|

| NRC NOTIFIED BY:  CHARLIE PIKE                 |LAST UPDATE DATE:  03/16/2003|

|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |

|10 CFR SECTION:                                 |                             |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION TO FLORIDA STATE INVOLVING RECOVERED SEA TURTLE FROM    |

| UNIT 1 INTAKE STRUCTURE                                                      |

|                                                                              |

| "A sea turtle with no external injuries but appearing to be distressed was   |

| recovered from the Unit 1 Intake Structure.  The State Stranding Coordinator |

| for sea turtles has been contacted."                                         |

|                                                                              |

| * * * UPDATE 11/23/01 AT 1255EST FROM CHARLIE PIKE TO S. SANDIN * * *        |

|                                                                              |

| "Turtle has died."                                                           |

|                                                                              |

| The licensee informed both the State of Florida and the NRC Resident         |

| Inspector.                                                                   |

|                                                                              |

| * * * UPDATE 1413EST ON 12/3/01 FROM JACK BREEN TO FANGIE JONES * * *        |

|                                                                              |

| At approximately 1215 EST on 12/3/01, a report was made to the Florida       |

| Department of Fish and Wildlife concerning the recovery of an injured sea    |

| turtle from the plant's intake canal.  The turtle was a green sea turtle in  |

| the intake canal that appeared distressed and looked to have a wound from a  |

| boat motor on its back.  It will be transferred to the State for             |

| rehabilitation.                                                              |

|                                                                              |

| The licensee plans to notify the NRC resident inspector.  Notified           |

| R2DO(MacAlpine).                                                             |

|                                                                              |

| * * * UPDATE 1333EST ON 12/15/01 FROM JACK BREEN TO JOHN MACKINNON * * *     |

|                                                                              |

| At approximately 1215 EST on 12/15/01, a report was made to the Florida      |

| Department of Fish and Wildlife Conservation Commission to pick up a Green   |

| Turtle for rehabilitation. The Green Turtle was taken from the plant's       |

| intake canal, and the turtle appears to have shark bites.                    |

|                                                                              |

| The licensee plans to notify the NRC resident inspector.  Notified R2DO      |

| (Chuck Ogle).                                                                |

|                                                                              |

| * * * UPDATE 1450EST ON 01/06/02 FROM TULLIDGE TO JOHN MACKINNON * * *       |

|                                                                              |

| At 1350EST, a notification to the State of Florida Department of Fish and    |

| Wildlife Conservation Commission was made due to finding an injured          |

| Loggerhead sea turtle in Unit 1 intake. The sea turtle was transported       |

| offsite for rehabilitation. R2DO (Tom Decker) notified.                      |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

|                                                                              |

| ***UPDATE 1330EST ON 4/23/02 FROM JACK BREEN TO RICH LAURA***                |

|                                                                              |

| The licensee rescued a  Loggerhead sea turtle from the intake canal.  The    |

| Florida Fish and Wildlife Conservation Commission was notified, and the      |

| turtle was turned over for rehabilitation.                                   |

|                                                                              |

| The NRC Resident Inspector was informed.  Notified R2DO (B. Bonser).         |

|                                                                              |

| ***UPDATE 1241EDT ON 5/29/02 FROM DAVE WILLIAMS TO RICHARD LAURA***          |

|                                                                              |

| The licensee reported that an offsite notification was made to the Florida   |

| Fish and Wildlife Conservation Commission concerning the discovery of a live |

| loggerhead sea turtle found in the plant's intake canal.  The turtle was     |

| lethargic and was sent for rehabilitation.                                   |

|                                                                              |

| The NRC Resident Inspector was informed.  Notified R2DO (K. Landis).         |

|                                                                              |

| ***** UPDATE AT 1125 EDT ON 06/01/02 FROM CHARLES MARPLE TO LEIGH TROCINE    |

| *****                                                                        |

|                                                                              |

| The following text is a portion of a facsimile received from the licensee:   |

|                                                                              |

| "At 1020 on 06/01/02, a notification was made to the Florida Fish and        |

| Wildlife Conservation Commission regarding a weak and emaciated Loggerhead   |

| turtle found in the plant intake barrier net.  The turtle will be sent       |

| off-site to the Marine Life Center for Rehabilitation."                      |

|                                                                              |

| The licensee notified the NRC resident inspector.  The NRC operations        |

| officer notified the R2DO (Kerry Landis).                                    |

|                                                                              |

| *****UPDATE AT 11:53 EDT ON 6/2/02 FROM MARPLE TO LAURA******                |

|                                                                              |

| "A notification was made to the Florida Fish and Wildlife Conservation       |

| Commission regarding a dead small green sea turtle found in the tangle net.  |

| The turtle will be maintained on ice for a postmortem examination."          |

|                                                                              |

| The NRC resident inspector was notified. Notified R2DO (K. Landis)           |

|                                                                              |

| *****UPDATE AT 12:45 EDT ON 7/18/02 FROM BREEN TO LAURA******                |

|                                                                              |

| A notification was made to the State regarding a dead green sea turtle that  |

| was removed from the intake canal.                                           |

|                                                                              |

| The NRC resident inspector will be notified.                                 |

|                                                                              |

| Notified R2DO (C. Payne                                                      |

|                                                                              |

| ***UPDATE AT 1045 EDT ON 10/20/02 FROM KORTH TO NORRIS***                    |

|                                                                              |

| A Loggerhead turtle was retrieved from the plant's intake canal.  The turtle |

| was in need of rehabilitation.  Per the plant's turtle permit, the Florida   |

| Fish and Wildlife Conservation Commission (FWCC) was notified at 0927 EDT.   |

|                                                                              |

| The NRC Resident Inspector has been notified.                                |

|                                                                              |

| Notified R2DO (Barr)                                                         |

|                                                                              |

| * * * UPDATE AT 1338 EDT ON 10/22/02 FROM KELLY KORTH TO GERRY WAIG * * *    |

|                                                                              |

| A Loggerhead turtle was retrieved from the plant's intake canal.  The turtle |

| was in need of rehabilitation.  Per the plant's turtle permit, the Florida   |

| Fish and Wildlife Conservation Commission (FWCC) was notified at 1250 EDT.   |

|                                                                              |

| The NRC Resident Inspector will be notified by the licensee.                 |

|                                                                              |

| Notified R2DO (Bob Haag)                                                     |

|                                                                              |

| * * * UPDATE ON 11/22/2002 @ 1821 BY FIELDS TO GOULD * * *                   |

|                                                                              |

| The licensee notified the Florida Department of Environmental Protection of  |

| the recovery of a distressed loggerhead sea turtle from their intake canal.  |

| The turtle was taken to a rehabilitation facility.                           |

|                                                                              |

| The NRC Resident inspector will be notified.  Notified R2DO (David Ayres).   |

|                                                                              |

| * * * UPDATE AT 1320 EST ON 12/16/02 FROM BILL PARKS TO GERRY WAIG * * *     |

|                                                                              |

| "On 12-16-02, two loggerhead turtles were retrieved from the plant's intake  |

| canal. The turtles were determined to be in need of rehabilitation. The      |

| injuries to the turtles are not causal to plant operation. Per the plant's   |

| turtle permit, the Florida Fish and Wildlife Conservation Commission (FWCC)  |

| was notified at 1230 EST. This non-emergency notification is being made      |

| pursuant to 10 CFR 50.72(b)(2)(xi) due to the notification of FWCC."         |

|                                                                              |

| The NRC Resident inspector will be notified.  Notified R2DO (Mike Ernstes).  |

|                                                                              |

| * * * UPDATE AT 1350 EST ON 1/25/03 FROM DAVE FIELDS TO MIKE RIPLEY * * *    |

|                                                                              |

| "The State of Florida Department of Environmental Protection was notified    |

| that an injured juvenile loggerhead sea turtle was retrieved from the plant  |

| intake canal.  The turtle was sent to a rehabilitation facility."            |

|                                                                              |

| The NRC Resident inspector will be notified.  Notified R2DO (Ken Barr).      |

|                                                                              |

| * * * * UPDATE AT 1140 EST ON 2/12/03 FROM ALAN HALL TO MIKE RIPLEY * * * *  |

|                                                                              |

|                                                                              |

| On 02/12/03 (approximately 1030 hrs), one loggerhead turtle was retrieved    |

| from the plant's intake canal.  The turtle was determined to be in need of   |

| rehabilitation.  The injury to the turtle is not causal to plant operation.  |

| Per the plant's turtle permit, the Florida Fish and Wildlife Conservation    |

| Commission (FWCC) was notified at 1040 EST.   This non-emergency             |

| notification is being made pursuant to 10 CFR 50.72(b)(2)(xi) due to the     |

| notification of FWCC."                                                       |

|                                                                              |

| The licensee notified the NRC Resident Inspector.  Notified R2 DO (C.        |

| Ogle).                                                                       |

|                                                                              |

| * * * UPDATE AT 1313 ON 3/16/03 FROM TEREZAKIS TO GOULD * * *                |

|                                                                              |

| On 3-16-03, a loggerhead sea turtle was retrieved from the plants intake     |

| canal. The turtle was determined to be in need of rehabilitation. The        |

| injuries to the turtle are not causal to plant operation.   Per the plant's  |

| turtle permit, the Florida Fish and Wildlife Conservation Commission (FWCC)  |

| was notified at 1140 EST.   This non-emergency notification is being made    |

| pursuant to 10 CFR 50.72(b)(2)(xi) due to the notification of FWCC.          |

|                                                                              |

| The NRC Resident inspector will be informed                                  |

|                                                                              |

| Notfied Reg 2 RDO(Ayers).                                                    |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39631       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 03/02/2003|

|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 16:00[EST]|

|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        03/02/2003|

+------------------------------------------------+EVENT TIME:        14:30[EST]|

| NRC NOTIFIED BY:  CHARLES PIKE                 |LAST UPDATE DATE:  03/15/2003|

|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |WALTER RODGERS       R2      |

|10 CFR SECTION:                                 |DAVID AYRES          R2      |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION TO STATE AGENCY OF EXPIRED GREEN SEA TURTLE FOUND AT    |

| BARRIER NET                                                                  |

|                                                                              |

| "NRC notification [is] being made due to state notification to [the] Florida |

| Wildlife Commission regarding a Green Sea Turtle found dead at barrier net   |

| pursuant to 10 CFR 50.72(b)(2)(xi)."                                         |

|                                                                              |

| The turtle was found on the surface at the barrier net with no injuries or   |

| abnormalities except for fresh cuts common for turtles coming through pipes. |

| The cause of death is unknown at this time. A necropsy is planned.           |

|                                                                              |

| The NRC Resident Inspector will be notified by the licensee.                 |

|                                                                              |

| * * * UPDATE ON 3/15/03 @ 1033 EST FROM TEREZAKIS TO CROUCH * * *            |

|                                                                              |

| "On 3-15-03, a green sea turtle was retrieved from the plant's intake canal. |

| The turtle was determined to be in need of rehabilitation.  The injuries to  |

| the turtle are not causal to plant operation. Per the plant's turtle permit, |

| the Florida Fish and Wildlife Conservation Commission (FWCC) was notified at |

| 0920 EST.  This non-emergency notification is being made pursuant to 10 CFR  |

| 50.72(b)(2)(xi) due to the notification of FWCC."                            |

|                                                                              |

| The NRC Resident Inspector will be notified by the licensee.                 |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39660       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  OR DEPT OF HEALTH RAD PROTECTION     |NOTIFICATION DATE: 03/11/2003|

|LICENSEE:  ROGUE VALLEY MEDICAL CENTER          |NOTIFICATION TIME: 11:59[EST]|

|    CITY:  MEDFORD                  REGION:  4  |EVENT DATE:        03/11/2003|

|  COUNTY:  JACKSON                   STATE:  OR |EVENT TIME:             [PST]|

|LICENSE#:  ORE-90064             AGREEMENT:  Y  |LAST UPDATE DATE:  03/11/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |MARK SHAFFER         R4      |

|                                                |KEVIN HSUEH          NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  EDWIN WRIGHT                 |                             |

|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT: MISSING BRACHYTHERAPY IRIDIUM-192 SEED.              |

|                                                                              |

| Dr. Sinnott called to report the loss of an Ir-192 brachytherapy seed with a |

| current activity of 6 millicuries.  The source was last visually inventoried |

| in December 2002.  The loss was noted yesterday, March 9, 2003, while the    |

| physicist was packaging sources for return to the manufacturer.              |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39663       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  WA DIVISION OF RADIATION PROTECTION  |NOTIFICATION DATE: 03/12/2003|

|LICENSEE:  PM TESTING LABORATORY                |NOTIFICATION TIME: 11:11[EST]|

|    CITY:  Tacoma                   REGION:  4  |EVENT DATE:        03/05/2003|

|  COUNTY:                            STATE:  WA |EVENT TIME:        20:00[PST]|

|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  03/12/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |MARK SHAFFER         R4      |

|                                                |THOMAS ESSIG         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  ARDEN SCROGGS                |                             |

|  HQ OPS OFFICER:  RICH LAURA                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| WA AGREEMENT STATE REPORT ON POSSIBLE OVEREXPOSURE INCIDENT                  |

|                                                                              |

|                                                                              |

| "Licensee: PM TESTING LABORATORY                                             |

| "Licensee number: WN-11R047-1                                                |

| "Type of licensee: Industrial Radiography                                    |

|                                                                              |

| "Date of event: March 5, 2003                                                |

| "Location of event: Port of Tacoma, WA. German cargo ship  'Big Lift'        |

|                                                                              |

| "ABSTRACT: (as reported by licensee's representative) A radiographer and     |

| Assistant Radiographer were performing radiography at the Port of Tacoma, on |

| a German cargo ship  Big 'Lift'  on March 5, 2003, at approximately 10 PM    |

| [PST]. The work required the radiographers to use a cherry-picker type       |

| lifting vehicle to access the work area since the area was about 100 feet    |

| above deck level. The Radiographer and Assistant were both in the lift       |

| bucket, 2 feet apart, at the time of the incident. The industrial            |

| radiographic device (Amersham Corporation Model 660B, containing             |

| approximately 70 curies of iridium 192) with connected guide tube,           |

| collimator and control cables had been lifted into position and secured in   |

| the area of the intended exposure. The exposure device had been made ready   |

| for the exposure. The operation required the Radiographer and Assistant to   |

| move the lift as far from the exposure area as possible while extending the  |

| control cable.                                                               |

|                                                                              |

| "As the lift was being positioned away from the work area it swayed, this    |

| startled the radiographer who dropped the control cable. The sway also       |

| caused the lift's engine to stall. The action of dropping the control cable  |

| to the extent of its length and resulting sudden stop at the end of the drop |

| caused the source to become unshielded. Their survey meter immediately went  |

| off scale on the highest scale and their alarm-rate meters were alarming.    |

|                                                                              |

| "It took the radiographers, by their estimate, about 30 seconds to restart   |

| the [lift] vehicle, move the bucket so they could recapture the control      |

| cable and secure the source. When they were able to check their pocket       |

| ion-chambers, they found them off scale. Work was stopped for the day and    |

| both film badges were sent for processing.                                   |

|                                                                              |

| "Results from film badge processing and analysis indicated the Radiographer  |

| received a whole body exposure of 1600 millirem. This coincided with the     |

| calculations made by the Radiographer after the incident. The film badge for |

| the Assistant indicated an exposure of 1,423,000 millirem. When the badge    |

| processor was contacted and asked to reanalyze the film they stated they got |

| the same exposure.                                                           |

|                                                                              |

| "Since both radiographers were within 2 feet of each other in the lift       |

| basket and calculations confirmed that the Radiographer's exposure was 1600  |

| milliRem, it appears the exposure to the Assistant was incorrectly           |

| determined. In addition, the Assistant is not exhibiting any signs of an     |

| excessive exposure. The company is submitting a report of the incident. The  |

| Division is performing an investigation. Media, at present, are not          |

| involved.                                                                    |

|                                                                              |

| "What is the notification or reporting criteria involved? WAC 246-221-260,   |

| Reports of overexposures and excessive levels and concentrations.            |

|                                                                              |

| "Activity and Isotope(s) involved? 70 curies of Iridium 192.                 |

|                                                                              |

| "Overexposure? Until the investigation indicates otherwise, the process      |

| report of the Assistant's film badge indicates a whole body exposure of      |

| about 1,423,000 milliRem. The over exposure is apparently not real since     |

| calculations using exposure time, distance and source activity and a second  |

| film badge, worn by another individual closely associated with the first all |

| indicate exposure is unusual but much lower. Staff will investigate."        |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39670       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  WESTINGHOUSE                         |NOTIFICATION DATE: 03/14/2003|

|LICENSEE:  ABB INC                              |NOTIFICATION TIME: 15:47[EST]|

|    CITY:  PITTSBURGH               REGION:  1  |EVENT DATE:        03/14/2003|

|  COUNTY:                            STATE:  PA |EVENT TIME:             [EST]|

|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  03/14/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |DAVID AYRES          R2      |

|                                                |MARK SHAFFER         R4      |

+------------------------------------------------+JACK FOSTER          NRR     |

| NRC NOTIFIED BY:  HANK SEPP                    |BRIAN MCDERMOTT      R1      |

|  HQ OPS OFFICER:  YAMIR DIAZ                   |KENNETH O'BRIEN      R3      |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| 10 CFR PART 21 REPORT REGARDING FAILURES OF ABB CIRCUIT  BREAKERS            |

|                                                                              |

| Circuit breakers manufactured by ABB Inc. and used for Class 1E applications |

| by Westinghouse were shipped to the Calvert Cliffs Plant with model 5        |

| operating mechanisms installed. Recently, Westinghouse had retrofitted the   |

| breakers with model 7 operating mechanisms manufactured by ABB Inc.          |

| Westinghouse validated that the original breaker qualifications (for Class   |

| 1E applications) are still applicable with the model 7 operating mechanism   |

| installed. Two of these breakers failed to close and latch during testing at |

| Calvert Cliffs. The first breaker failed to close and latch during           |

| acceptance testing on January 18, 2003. The second breaker failed to close   |

| and latch during its installation acceptance test in the breaker cubicle on  |

| January 27, 2001.                                                            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39672       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 03/16/2003|

|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 10:58[EST]|

|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        03/16/2003|

+------------------------------------------------+EVENT TIME:        05:25[CST]|

| NRC NOTIFIED BY:  RAYMOND SWAFFORD             |LAST UPDATE DATE:  03/16/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |DAVID AYRES          R2      |

|10 CFR SECTION:                                 |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          Y       31       Power Operation  |31       Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| ACCIDENT MITIGATION SYSTEM INADVERTENT ISOLATION                             |

|                                                                              |

| The following information was obtained from the licensee via facsimile:      |

|                                                                              |

| "ON 03/16/2003 AT APPROXIMATELY 0525 CST, HPCI ISOLATED AND TRIPPED DURING   |

| PERFORMANCE OF 2-SR-3.5.1.7, HPCI MAIN & BOOSTER PUMP SET DEVELOPED HEAD &   |

| FLOW RATE TEST.   INITIAL INDICATIONS [ARE] HPCI ISOLATED ON A HIGH STEAM    |

| FLOW SIGNAL.  THERE IS NO INDICATION OF A STEAM LINE BREAK.  INVESTIGATION   |

| IS ON-GOING.                                                                 |

|                                                                              |

| "THIS IS REPORTABLE AS A 8-HOUR NON-EMERGENCY EVENT 10CFR50.72(b)(3)(v),     |

| AND A 60 DAY WRITTEN REPORT 10CFR50.73(a)(2)(vii),  AS "ANY EVENT OR         |

| CONDITION THAT AT THE TIME OF DISCOVERY COULD HAVE PREVENTED THE             |

| [FULFILLMENT] OF THE SAFETY FUNCTION OF STRUCTURES OR SYSTEMS THAT ARE       |

| NEEDED TO:                                                                   |

|                                                                              |

| (A)  SHUTDOWN THE REACTOR AND MAINTAIN IT IN A SAFE SHUTDOWN CONDITION       |

| (B)  REMOVE RESIDUAL HEAT                                                    |

| (C)  CONTROL THE RELEASE OF RADIOACTIVE MATERIAL; OR                         |

| (D)  MITIGATE THE CONSEQUENCES OF AN ACCIDENT."                              |

|                                                                              |

| The licensee will notify the NRC Resident Inspector.                         |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39673       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COMANCHE PEAK            REGION:  4  |NOTIFICATION DATE: 03/17/2003|

|    UNIT:  [1] [] []                 STATE:  TX |NOTIFICATION TIME: 01:25[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/16/2003|

+------------------------------------------------+EVENT TIME:        21:49[CST]|

| NRC NOTIFIED BY:  STEVEN SEWELL                |LAST UPDATE DATE:  03/17/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MARK SHAFFER         R4      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     M/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MANUAL REACTOR TRIP AND AUXILIARY FEEDWATER ACTUATION DUE TO CONDENSATE PUMP |

| TRIP                                                                         |

|                                                                              |

| The following information was obtained from the licensee via facsimile:      |

|                                                                              |

| "Unit 1 manual reactor trip (RPS actuation) was initiated at 2149 [CST] due  |

| to a loss of main feedwater.  The event was initiated by a trip of           |

| Condensate Pump 1-01 which resulted in a trip of Main Feedwater Pump 'B' and |

| Main Feedwater Pump 'A' due to inadequate suction pressure.                  |

|                                                                              |

| "An automatic initiation of Auxiliary Feedwater (ESF actuation) occurred     |

| when both Main Feedwater Pumps tripped.                                      |

|                                                                              |

| "Unit 1 is currently in Hot Standby (Mode 3) with decay heat removal via     |

| Auxiliary Feedwater and Steam Dump to the Main Condenser.  All safety        |

| systems responded appropriately.  The cause of the Condensate Pump 1-01 trip |

| is currently under investigation."                                           |

|                                                                              |

| All control rods fully inserted.  There are no indications of any            |

| primary-to-secondary leakage.  There were no primary or secondary power      |

| operated relief or manual relief valves lifted.  The electrical grid is      |

| stable.  The licensee did receive low steam generator level alarms (as       |

| expected) but levels were recovered and are being maintained via the         |

| Auxiliary Feedwater system.  Unit 2 is stable and was not affected by the    |

| Unit 1 trip.                                                                 |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

+------------------------------------------------------------------------------+