Event Notification Report for March 11, 2003






                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           03/10/2003 - 03/11/2003



                              ** EVENT NUMBERS **



39640  39641  39642  39643  39650  39651  39652  39653  39654  39657  39658 

39659  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39640       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  LOUISIANA DEPT ENV QUALITY           |NOTIFICATION DATE: 03/06/2003|

|LICENSEE:  COMPUTALOG WIRELINE SERVICES         |NOTIFICATION TIME: 15:29[EST]|

|    CITY:                           REGION:  4  |EVENT DATE:        03/05/2003|

|  COUNTY:                            STATE:  LA |EVENT TIME:             [CST]|

|LICENSE#:  LA-4413-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  03/06/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |DALE POWERS          R4      |

|                                                |DOUG BROADDUS        NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  SCOTT BALCKWELL              |                             |

|  HQ OPS OFFICER:  YAMIR DIAZ                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| IRRETRIEVABLE SEALED SOURCE                                                  |

|                                                                              |

| "Computalog was performing analysis of the amount of petroleum in the        |

| Strategic Petroleum Reserve salt dome in Hackberry, LA.   The tool hung up   |

| on the casing near the top and fell to the bottom.   The source was a 172    |

| mCi [milli Curie]  source of Cs- 137 and it fell to a depth of 4000 ft.      |

| Attempts were not made to retrieve the tool because the dome is so wide at   |

| the bottom. DEQ is waiting on the written report for additional              |

| information."                                                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39641       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  LOUISIANA DEPT ENV QUALITY           |NOTIFICATION DATE: 03/06/2003|

|LICENSEE:  HARTFIELD TECHNICAL SERVICES         |NOTIFICATION TIME: 15:30[EST]|

|    CITY:                           REGION:  4  |EVENT DATE:        02/17/2003|

|  COUNTY:                            STATE:  LA |EVENT TIME:             [CST]|

|LICENSE#:  LA-4543-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  03/06/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |DALE POWERS          R4      |

|                                                |DOUG BROADDUS        NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  SCOTT BLACKWELL              |                             |

|  HQ OPS OFFICER:  YAMIR DIAZ                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| IRRETRIEVABLE SEALED SOURCE                                                  |

|                                                                              |

| "A 3 Ci [Curie] sealed source of AmBe 241 was lost down hole on February 17, |

| 2003 at a depth of 6600 ft.   Attempts were made to retrieve the source but  |

| they were unsuccessful.   A vented bridge plug was set at 5335 ft and low    |

| permeability cement was dumped until 5300 ft. Additional information will be |

| sent at a later date."                                                       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39642       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  LOUISIANA DEPT ENV QUALITY           |NOTIFICATION DATE: 03/06/2003|

|LICENSEE:  HALIBURTON                           |NOTIFICATION TIME: 15:31[EST]|

|    CITY:                           REGION:  4  |EVENT DATE:        02/14/2003|

|  COUNTY:                            STATE:  LA |EVENT TIME:             [CST]|

|LICENSE#:  LA-2353-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  03/06/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |DALE POWERS          R4      |

|                                                |DOUG BROADDUS        NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  SCOTT BLACKWELL              |                             |

|  HQ OPS OFFICER:  YAMIR DIAZ                   |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| IRRETRIEVABLE SEALED SOURCE                                                  |

|                                                                              |

| "An NWA tool with a 2 Ci [Curie] source of Cs-137 and a 4 Ci source of       |

| Am241Be were lost down hole at 11540 feet on February 14, 2003.   Attempts   |

| were made until February 20, 2003 to retrieve the tool, but they were        |

| unsuccessful. The well was back filled with 500 ft of cement to a depth of   |

| 10881 ft.   DEQ is currently waiting for the written report for additional   |

| information."                                                                |

+------------------------------------------------------------------------------+



!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!

+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39643       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PERRY                    REGION:  3  |NOTIFICATION DATE: 03/07/2003|

|    UNIT:  [1] [] []                 STATE:  OH |NOTIFICATION TIME: 19:17[EST]|

|   RXTYPE: [1] GE-6                             |EVENT DATE:        03/07/2003|

+------------------------------------------------+EVENT TIME:        14:40[EST]|

| NRC NOTIFIED BY:  ROBERT KIDDER                |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MONTE PHILLIPS       R3      |

|10 CFR SECTION:                                 |JOHN DAVIDSON        IAT     |

|DDDD 73.71(b)(1)         SAFEGUARDS REPORTS     |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       83       Power Operation  |83       Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| 1- HOUR SAFEGUARD REPORT                                                     |

|                                                                              |

| Discovery of criminal act involving individual granted access to the site.   |

| Immediate compensatory measures taken upon discovery.  Contact the           |

| Headquarters Operations Officer for details.                                 |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

|                                                                              |

| **** RETRACTION ON 03/10/03 AT 1555 ET BY TOM VEITCH TAKEN BY MACKINNON      |

| ****                                                                         |

|                                                                              |

| After additional review, it was determined that drugs do not fall into the   |

| classification of contraband and thus need not be reported under this        |

| criterion.  R3DO (Ken O'Brien) notified.                                     |

|                                                                              |

| The NRC Resident Inspector was notified of this retraction by the licensee.  |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39650       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 03/10/2003|

|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 00:46[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/09/2003|

+------------------------------------------------+EVENT TIME:        20:47[CST]|

| NRC NOTIFIED BY:  JONATHAN PIERCE              |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |DALE POWERS          R4      |

|10 CFR SECTION:                                 |                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          N       0        Hot Standby      |0        Hot Standby      |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SAFETY INJECTION SYSTEM  ACTUATION AND CAUSE UNDER INVESTIGATION             |

|                                                                              |

| "At 20:47 on 3/9/03, Unit 2 experienced a Safety Injection while the plant   |

| was stable at NOP(2235 psig)/NOT                                             |

| (567 degrees) in Mode 3.  All systems actuated as designed.  An operator was |

| operating the 'B'  S/G PORV shortly                                          |

| before the event occurred.  All MSIVs were closed for ongoing work on the    |

| main turbine. The Sequence of                                                |

| events report showed all 3 channels of steam pressure spiking low on the 'B' |

| Steam Generator as the cause of the event. Initial look at trends on the     |

| integrated computer system showed [that] steam pressure channels did not     |

| lower to a point to cause the safety injection.  An Event Review Team is     |

| being formed to investigate this event.                                      |

|                                                                              |

| "A Reactor Coolant System PORV opened due to high pressure when the Spray    |

| valves closed due to the Instrument Air isolation (due to phase 'A') with    |

| the Pressurizer Heaters in manual. The Pressurizer heaters were secured and  |

| Reactor coolant System pressure stabilized.  All ESF systems actuated as     |

| designed. The following systems actuated: Auxiliary Feedwater, Safety        |

| Injection, Phase 'A', Control Room Envelope and Fuel Handling Building HVAC  |

| systems, Essential Cooling Water, Component Cooling Water, Emergency Diesel  |

| Generators and ESF sequencers."                                              |

|                                                                              |

| There was no safety injection since pressure was maintained above 2199 psi   |

| during the transient (Hi Head is 1700 psi).  Heat removal is being performed |

| through S/G PORVs and Unit 2 is currently stable at Mode 3.                  |

|                                                                              |

| The Licensee notified the NRC Resident Inspector.                            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39651       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: WATTS BAR                REGION:  2  |NOTIFICATION DATE: 03/10/2003|

|    UNIT:  [1] [] []                 STATE:  TN |NOTIFICATION TIME: 03:45[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/10/2003|

+------------------------------------------------+EVENT TIME:        00:12[EST]|

| NRC NOTIFIED BY:  JOHN RODEN                   |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |STEPHEN CAHILL       R2      |

|10 CFR SECTION:                                 |CAROLYN EVANS        R2      |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     A/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC REACTOR TRIP DUE TO TURBINE TRIP ON GENERATOR DIFFERENTIAL RELAY   |

| ACTUATION                                                                    |

|                                                                              |

| "At 0012 EST on March 10, 2003, with Watts Bar Unit 1 in Mode 1 at 100%      |

| power, the reactor tripped due to an automatic signal.  All plant safety     |

| systems were in service at the time to the trip, except  for the 2B-B diesel |

| generator which was out of service for scheduled maintenance, and all        |

| [safety systems] responded as designed.  All control rods inserted as        |

| required and the Auxiliary Feedwater System [AFW] initiated as expected.     |

|                                                                              |

| "The reactor trip resulted from a turbine trip signal that was generated as  |

| a result of a main generator/transformer differential electrical relay       |

| actuation.  The plant is currently stable in Mode 3 and will remain in this  |

| Mode until completion of the investigation."                                 |

|                                                                              |

| AFW was removed from operation and the main feed pumps have resumed normal   |

| feed to the Steam Generators.  The Licensee notified the NRC Resident        |

| Inspector.                                                                   |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Hospital                                         |Event Number:   39652       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  OAKWOOD HOSPITAL                     |NOTIFICATION DATE: 03/10/2003|

|LICENSEE:  OAKWOOD HOSPITAL                     |NOTIFICATION TIME: 11:43[EST]|

|    CITY:  DEARBORN                 REGION:  3  |EVENT DATE:        03/10/2003|

|  COUNTY:  WAYNE                     STATE:  MI |EVENT TIME:        10:00[EST]|

|LICENSE#:  21-04515-01           AGREEMENT:  N  |LAST UPDATE DATE:  03/10/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KEN O'BRIEN          R3      |

|                                                |KEVIN HSUEH          NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  TALJIT SANDHER               |                             |

|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|LOTH 35.3045(a)(3)       DOSE TO OTHER SITE > SP|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MEDICAL EVENT TO AN UNINTENDED SITE                                          |

|                                                                              |

| At 1000 EST on 03/10/03  it was discovered that a patient at Oakwood         |

| Hospital located in Dearborn, MI had implanted 42 Iodine-125 seeds into his  |

| bulb of urethra instead of his prostrate.  The urologist had misinterpreted  |

| the ultrasound scan.   The total activity of the Iodine-125 seeds was 14.2   |

| millicuries, each seed was 0.338 millicuries. The patient and his Medical    |

| Doctor have been notified of the error.  No side affects to the patient.     |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39653       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 03/10/2003|

|    UNIT:  [] [2] []                 STATE:  TN |NOTIFICATION TIME: 12:12[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/10/2003|

+------------------------------------------------+EVENT TIME:        09:18[EST]|

| NRC NOTIFIED BY:  CALVIN FIELDS                |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CAROLYN EVANS        R2      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     M/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MANUAL REACTOR TRIP                                                          |

|                                                                              |

| Unit 2 Manual Reactor Trip at 0918 ET on 03/10/03 due to the following       |

| sequence events:                                                             |

|                                                                              |

| At 0903 Hotwell Pump "B" tripped on neutral overcurrent.                     |

|                                                                              |

| At 0911 Both # 7 Heater Drain Tank Pumps tripped.                            |

|                                                                              |

| Per AOP-S.04 started decreasing unit power.                                  |

|                                                                              |

| At 0918 Main Feedwater Pump "A"  tripped initiating Unit Runback Balance of  |

| Plant (BOP).                                                                 |

|                                                                              |

| At 0918 Manual Reactor Trip.                                                 |

|                                                                              |

| Due to both Main Feedwater Pump's rupture discs blown plant is using Steam   |

| Generator Atmospheric Relief Valves to cool the plant and maintain a Hot     |

| Standby condition.  No leaking steam generator tubes.  The electrical grid   |

| is stable and the emergency diesel generators are fully operable if needed.  |

| Sequoyah Unit 1 is in coastdown.                                             |

|                                                                              |

|                                                                              |

| The NRC Resident Inspector was notified of this event by the licensee.       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39654       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COMANCHE PEAK            REGION:  4  |NOTIFICATION DATE: 03/10/2003|

|    UNIT:  [1] [2] []                STATE:  TX |NOTIFICATION TIME: 14:26[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/07/2003|

+------------------------------------------------+EVENT TIME:        17:00[CST]|

| NRC NOTIFIED BY:  NEIL HARRIS                  |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MARK SHAFFER         R4      |

|10 CFR SECTION:                                 |                             |

|HFIT 26.73               FITNESS FOR DUTY       |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| FITNESS FOR DUTY FOR ALCOHOL                                                 |

|                                                                              |

| On 03/07/03 at 1700 hours CT a contract employee was asked to take a for     |

| cause test for alcohol.  He refused to take the test and he then resigned    |

| from his position.  At 1731 hours his unescorted access was terminated.  The |

| licensee escorted the individual offsite and to his residence.  His work     |

| record was reviewed and nothing unusual was found.                           |

|                                                                              |

| The NRC Resident Inspector will be informed by the licensee.                 |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39657       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: DIABLO CANYON            REGION:  4  |NOTIFICATION DATE: 03/10/2003|

|    UNIT:  [] [2] []                 STATE:  CA |NOTIFICATION TIME: 17:32[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/10/2003|

+------------------------------------------------+EVENT TIME:        07:31[PST]|

| NRC NOTIFIED BY:  JEFF KINSLEY                 |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MARK SHAFFER         R4      |

|10 CFR SECTION:                                 |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| REACTOR COOLANT SYSTEM LOW TEMPERATURE OVERPRESSURE PROTECTION (LTOP) NOT    |

| ENABLED                                                                      |

|                                                                              |

| During the eleventh refueling outage on Unit 2 (2R11) the reactor coolant    |

| system low temperature overpressure (LTOP) protection was inoperable due to  |

| the individual power operated relief valves (PORV's) control switches being  |

| selected to the "closed" position. LTOP was unable to perform its required   |

| automatic function from 0829 PT on 03/09/03 until the discovery time of 0731 |

| PT on 03/10/03.  This discrepancy was discovered by the operator during the  |

| beginning of shift board walkdown, at which time the PORV selector switches  |

| were returned to "auto" and LTOP protection was enabled.  At no time were    |

| any of the LTOP setpoints challenged.  Residual Heat Removal (RHR) pump      |

| suction relief valves (setpoint is 450 psi) were also available during this  |

| time frame to provide overpressure protection. Reactor Coolant temperature   |

| was 109 degrees F.  LTOP setpoint was for 435 psi.    The LTOP PORV's        |

| control switches were closed during the vacuum degas procedure.   Licensee   |

| is still investigating this event.                                           |

|                                                                              |

| The NRC Resident Inspector was notified of this event by the licensee.       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39658       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: RIVER BEND               REGION:  4  |NOTIFICATION DATE: 03/10/2003|

|    UNIT:  [1] [] []                 STATE:  LA |NOTIFICATION TIME: 18:24[EST]|

|   RXTYPE: [1] GE-6                             |EVENT DATE:        03/10/2003|

+------------------------------------------------+EVENT TIME:        11:37[CST]|

| NRC NOTIFIED BY:  SAM BELCHER                  |LAST UPDATE DATE:  03/10/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MARK SHAFFER         R4      |

|10 CFR SECTION:                                 |                             |

|AINC 50.72(b)(3)(v)(C)   POT UNCNTRL RAD REL    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       87       Power Operation  |87       Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| PRIMARY CONTAINMENT AIRLOCK SEALS DEFLATED.                                  |

|                                                                              |

| At 1137 CST on 03/10/03, with the plant at 87% power, the Main Control Room  |

| team received indications that the seals were deflated on both doors of      |

| primary containment airlock JRB-DRA1.  Personnel were exiting containment    |

| through the airlock at this time.  Personnel were dispatched and airlock     |

| integrity was restored at 1208 CST.  The cause of the condition appears to   |

| be related to the mechanical interlock.  This interlock did not function as  |

| required to prevent deflation of the seals on both doors concurrently.  This |

| condition is being evaluated.                                                |

|                                                                              |

| This condition could have resulted in a loss of function of the Primary      |

| Containment to confine a postulated release of radioactive material to       |

| within limits.                                                               |

|                                                                              |

| The Senior Resident Inspector was notified of this event by the licensee.    |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39659       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 03/11/2003|

|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 05:23[EST]|

|   RXTYPE: [1] GE-4                             |EVENT DATE:        03/10/2003|

+------------------------------------------------+EVENT TIME:        22:38[CST]|

| NRC NOTIFIED BY:  ANDREW OHRABLO               |LAST UPDATE DATE:  03/11/2003|

|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MARK SHAFFER         R4      |

|10 CFR SECTION:                                 |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Refueling        |0        Refueling        |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| POTENTIAL RAD GROUND RELEASE PATH DISCOVERED DUE TO LOSS OF SECONDARY        |

| CONTAINMENT                                                                  |

|                                                                              |

| "This notification is being made pursuant to NRC regulation                  |

| 10CFR50.72(b)(3)(v)(D), any event or condition that at the time of discovery |

| could have prevented the fulfillment of the safety function of structures or |

| systems that are needed to mitigate the consequences of an accident.         |

|                                                                              |

| "On March 10, 2003 at 22:38, it was determined that the secondary            |

| containment was inoperable due to a leak in the Z sump manway gasket. The    |

| plant was in Mode 5, shutdown, performing fuel shuffle when secondary        |

| containment was declared inoperable. LCO 3.6.4.1 was entered. The fuel       |

| shuffle was secured at 22:40 after the completion of the fuel move that was  |

| in progress. No additional Core Alterations or OPDRVs [Operations            |

| Potentially Draining the Reactor Vessel] were in progress. Upon              |

| investigation into the secondary containment operability, it was determined  |

| that a non-Tech Spec surveillance performed on dayshift also rendered        |

| secondary containment inoperable due to additional leakage pathway via the Z |

| sump.  A principal safety function of Secondary Containment is to limit the  |

| ground level release to the environs of airborne radioactive materials       |

| resulting from a fuel handling accident.                                     |

|                                                                              |

| "As a result of the alignment of the Z sump the potential existed that if a  |

| radioactive release were to occur due to a fuel handling accident, part of   |

| the filtered release via Standby Gas Treatment System could be a ground      |

| level release vice a release through the Elevated Release Point. The         |

| surveillance has been completed and the additional leakage paths that were   |

| opened due to the surveillance have been sealed. The leaking manway gasket   |

| was determined to be due to not adequately torquing the gasket bolts. The    |

| bolts have been retorqued. Secondary containment was reestablished, and was  |

| declared OPERABLE at 02:55, 3-11-03.                                         |

|                                                                              |

| "The NRC Senior Resident has been notified."                                 |

+------------------------------------------------------------------------------+

                 