The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for January 22, 2003
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
01/21/2003 - 01/22/2003
** EVENT NUMBERS **
39517 39518
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39517 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: OHIO BUREAU OF RADIATION PROTECTION |NOTIFICATION DATE: 01/17/2003|
|LICENSEE: ABB INCORPORATED |NOTIFICATION TIME: 09:44[EST]|
| CITY: COLUMBUS REGION: 3 |EVENT DATE: 01/16/2003|
| COUNTY: STATE: OH |EVENT TIME: 17:00[EST]|
|LICENSE#: 03211250000 AGREEMENT: Y |LAST UPDATE DATE: 01/17/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |DAVID HILLS R3 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: SNEE | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LEAKING PROMETHIUM - 147 SOURCE |
| |
| The licensee informed the Ohio Department of Health on 1/16/03 of a leaking |
| Pm-147 source possibly caused by a defective or failed material. The source |
| had been received by ABB from a customer in Japan (Yokagawa Electric). The |
| source was contained and no spread of contamination was detected. ABB will |
| inform the facility in Japan and properly dispose of the source. The |
| leaking source was a 70 millicurie Pm-147, ABB model S-11. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39518 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 01/17/2003|
|LICENSEE: GEOTECH ENGINEERING AND TESTING |NOTIFICATION TIME: 12:18[EST]|
| CITY: HOUSTON REGION: 4 |EVENT DATE: 01/16/2003|
| COUNTY: STATE: TX |EVENT TIME: 16:45[CST]|
|LICENSE#: L03923-002 AGREEMENT: Y |LAST UPDATE DATE: 01/17/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GARY SANBORN R4 |
| |FRED BROWN NMSS |
+------------------------------------------------+CATHY HANEY IAT |
| NRC NOTIFIED BY: JIM OGDEN | |
| HQ OPS OFFICER: RICH LAURA | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TEXAS AGREEMENT STATE REPORT FOR STOLEN MOISTURE DENSITY GAUGE |
| |
| "Event location: Near intersection of Milam and 700 block of Clay Road, |
| Houston, Texas (Downtown) |
| "Event type: RAM Stolen (Stolen Moisture-Density Gauge) |
| "Notifications: TDH Medical Duty Officer, TDH/BRC, City of Houston Police |
| Department |
| |
| "Event description: Driver/operator returned to his vehicle at completion of |
| the work day (construction site for a Houston Metro Station) and discovered |
| the nuclear moisture density gauge and case are missing from his truck. The |
| chain and lock were still attached to the truck. The company believes the |
| gauge handle and latch were pried from the case. The gauge and case are |
| missing. The missing gauge is a Troxler Model 3411B, Serial No. 20098, with |
| two sealed sources: 8 millicuries of Cs-137, Serial No. 751355; and 40 |
| millicuries of Am-241/Be, Serial No. 4715582". |
+------------------------------------------------------------------------------+