Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for January 13, 2003




                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           01/10/2003 - 01/13/2003



                              ** EVENT NUMBERS **



39494  39498  39500  39501  39502  39503  39504  39505  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39494       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 01/07/2003|

|LICENSEE:  SPECTRO INSTRUMENTS                  |NOTIFICATION TIME: 18:32[EST]|

|    CITY:  MARBLE FALLS             REGION:  4  |EVENT DATE:        01/07/2003|

|  COUNTY:                            STATE:  TX |EVENT TIME:        16:24[CST]|

|LICENSE#:  L02788                AGREEMENT:  Y  |LAST UPDATE DATE:  01/07/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CHUCK CAIN           R4      |

|                                                |E. WILLIAM BRACH     NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  HELEN WATKINS                |                             |

|  HQ OPS OFFICER:  ARLON COSTA                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT ON LEAKING SOURCES                                    |

|                                                                              |

| Texas Department of Health received a telephone notification from Spectro    |

| Instruments that two 50 microcurie Fe-55 sources were leaking.  Sources S/N  |

| 5069LG and S/N 6172LG were leak tested 0.4 microcuries and 0.13 microcuries  |

| respectively.                                                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39498       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PERRY                    REGION:  3  |NOTIFICATION DATE: 01/10/2003|

|    UNIT:  [1] [] []                 STATE:  OH |NOTIFICATION TIME: 12:47[EST]|

|   RXTYPE: [1] GE-6                             |EVENT DATE:        01/10/2003|

+------------------------------------------------+EVENT TIME:        09:00[EST]|

| NRC NOTIFIED BY:  ALAN RABENOLD                |LAST UPDATE DATE:  01/10/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ROGER LANKSBURY      R3      |

|10 CFR SECTION:                                 |                             |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION TO LOCAL COUNTY EMERGENCY AGENCIES                      |

|                                                                              |

| "At 0905, an injury occurred to a worker when the individual received 2nd    |

| degree burns to his forearms.  The worker was treated by the Company First   |

| Aid Team and released to Radiation Protection Personnel for deconning the    |

| individual.  The burn area had some contamination of 100 to 400 counts above |

| background.  The individual was deconned by our Radiation Protection         |

| Personnel and our Company Medical Personnel and is no longer contaminated.   |

| The individual was released back to work.                                    |

| The local County Emergency Management Agencies were notified of the          |

| potential for transportation of the individual to a local hospital, but      |

| transportation will not be required.  The individual has requested no        |

| medical treatment from the local hospital.  The local County Emergency       |

| Management Agencies were re-notified that the individual would not be        |

| transported."                                                                |

|                                                                              |

| The State of Ohio and local Counties were informed of this event.            |

|                                                                              |

| The NRC Resident Inspector was notified of this event by the licensee.       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39500       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: LASALLE                  REGION:  3  |NOTIFICATION DATE: 01/10/2003|

|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 16:05[EST]|

|   RXTYPE: [1] GE-5,[2] GE-5                    |EVENT DATE:        01/10/2003|

+------------------------------------------------+EVENT TIME:        11:56[CST]|

| NRC NOTIFIED BY:  AL BAILEY                    |LAST UPDATE DATE:  01/10/2003|

|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ROGER LANKSBURY      R3      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     M/R        Y       91       Power Operation  |0        Hot Shutdown     |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MANUAL SCRAM DUE TO LOWERING REACTOR VESSEL WATER LEVEL                      |

|                                                                              |

| "This report is being made pursuant to 10CFR50.72(b)(2)(iv)(B), RPS          |

| Actuation (scram). At 11:56 CDST on January 10,2003, during normal           |

| operation, unit 2 was manually scrammed due to lowering vessel water level.  |

| The lowering water level was from the loss of the 2B Condensate pump and the |

| 2A & 2C Heater Drain pumps which resulted in a loss of both Turbine Driven   |

| Feed Pumps. ECCS equipment responded as expected (no automatic injection or  |

| starts). Hot Standby Mode of Operation was achieved with out difficulties    |

| and residual heat is being rejected to the condenser. No Safety Relief       |

| Valves actuated.                                                             |

|                                                                              |

| "Initial investigation revealed that the 2B condensate pump motor failed and |

| may have resulted in an electrical fluctuation on electrical buses resulting |

| in tripping some non-essential components. Further investigation, including  |

| troubleshooting is in progress for activities related to the condensate and  |

| heater drain pump loss."                                                     |

|                                                                              |

| All rods properly inserted into the core.  The licensee notified the NRC     |

| Resident Inspector.                                                          |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39501       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 01/11/2003|

|    UNIT:  [1] [2] []                STATE:  NJ |NOTIFICATION TIME: 07:15[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        01/10/2003|

+------------------------------------------------+EVENT TIME:        23:20[EST]|

| NRC NOTIFIED BY:  JOE SULLIVAN                 |LAST UPDATE DATE:  01/11/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |RICHARD CONTE        R1      |

|10 CFR SECTION:                                 |                             |

|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOSS OF ALL METEOROLOGICAL DATA FOR WIND SPEED, DIRECTION, AND TEMPERATURE   |

|                                                                              |

| This report is from the Salem/Hope Creek site.  Both Salem units and the     |

| Hope Creek unit are in power operation.                                      |

|                                                                              |

| "This 8-hour notification is being made to report that the Salem and Hope    |

| Creek site lost all meteorological data for wind speed, direction and        |

| temperature at 1520 [EST] on 1/10/03.  All three units are operating at 100% |

| power.  No actuations have taken place related to this event.  The cause of  |

| this loss is being investigated.  Procedural guidance is available to obtain |

| the necessary data from the national weather service should this data be     |

| necessary."                                                                  |

|                                                                              |

| The NRC resident inspector will be notified.                                 |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39502       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: MCGUIRE                  REGION:  2  |NOTIFICATION DATE: 01/11/2003|

|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 23:45[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        01/11/2003|

+------------------------------------------------+EVENT TIME:        21:45[EST]|

| NRC NOTIFIED BY:  LARRY TUMBLESON              |LAST UPDATE DATE:  01/12/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ROBERT HAAG          R2      |

|10 CFR SECTION:                                 |JOHN DAVIDSON        IAT     |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION TO FBI AND LOCAL LAW ENFORCEMENT                        |

|                                                                              |

| At 2345 EST on 1/11/03, the licensee reported that they had contacted the    |

| Charlotte, NC FBI and the Charlotte-Mecklenburg, NC police department        |

| concerning a report they received at 2145 EST on 1/11/03 from the Mt.        |

| Gilead, NC Volunteer Fire Department concerning a plastic traffic cone that  |

| was set on fire on Highway 73 approximately one-eighth mile east of the main |

| entrance road to the McGuire Station and approximately one-half mile from    |

| the owner-controlled area checkpoint on the entrance road.                   |

|                                                                              |

| The licensee will be informing the NRC resident inspector.                   |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39503       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: DIABLO CANYON            REGION:  4  |NOTIFICATION DATE: 01/12/2003|

|    UNIT:  [1] [2] []                STATE:  CA |NOTIFICATION TIME: 18:14[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        01/12/2003|

+------------------------------------------------+EVENT TIME:        13:10[PST]|

| NRC NOTIFIED BY:  MR HARBOR                    |LAST UPDATE DATE:  01/12/2003|

|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHUCK CAIN           R4      |

|10 CFR SECTION:                                 |                             |

|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOSS OF MET TOWER DATA                                                       |

|                                                                              |

| "Event: On January 7, 2003 the Primary Meteorological (Met) Tower was        |

| removed from service to repair                                               |

| the 76-meter wind direction function. Removing the primary tower from        |

| service results in all                                                       |

| functions (i.e. wind speed, wind direction, and air temperature) being       |

| declared INOPERABLE.                                                         |

| On January 12, 2003 at 1310, the 60-meter air temperature for the Back-up    |

| Meteorological Tower                                                         |

| was declared INOPERABLE due to faulty readings.                              |

|                                                                              |

| "Effects on Plant: This has resulted in a loss of the capability to          |

| determine differential temperature for emergency                             |

| assessment (plume}.                                                          |

|                                                                              |

| "Cause: The cause of the faulty Back-up Met Tower 60-meter temperature       |

| indication is under                                                          |

| investigation. The Primary Met tower is INOPERABLE because it is disabled to |

| correct the 76-                                                              |

| meter wind direction function.                                               |

|                                                                              |

| "Actions Taken or Planned: 1) The portable meteorological monitoring system  |

| is being placed in-service per Diablo Canyon Power Plant (DCPP) Equipment    |

| Control Guideline (ECG) 40.l-B.1. This restores differential temperature     |

| monitoring capability. 2) DCPP maintenance personnel have been dispatched to |

| repair either the primary or back-up tower. The plant will remain in a 7 day |

| ECG until either towers air temperature monitoring function has been         |

| restored to OPERABLE status."                                                |

|                                                                              |

| The NRC Resident Inspector. has been notified.                               |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39504       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: BRUNSWICK                REGION:  2  |NOTIFICATION DATE: 01/12/2003|

|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 18:40[EST]|

|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        01/12/2003|

+------------------------------------------------+EVENT TIME:        15:53[EST]|

| NRC NOTIFIED BY:  DAN HARDIN                   |LAST UPDATE DATE:  01/12/2003|

|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ROBERT HAAG          R2      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     A/R        Y       94       Power Operation  |0        Hot Shutdown     |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC SCRAM ON LOWERING REACTOR VESSEL WATER LEVEL DUE TO FEED PUMP      |

| TRIP                                                                         |

|                                                                              |

| "Unit 1 was operating at 94 percent power (presently max power) when 1B      |

| Reactor Feed Pump (RFP) low oil pressure annunciator was received coincident |

| with 1B RFP trip at 1552. Reactor water level lowered and initiated an       |

| automatic SCRAM as the Reactor Operator was inserting a manual SCRAM at      |

| 1553. All systems initiated and isolated as required. A group 6 [containment |

| atmospheric and sampling] and Group 2 [drywell floor equipment drain         |

| isolation valves] isolation was received on low Reactor water level and      |

| verified. The Emergency Diesel Generators started as expected due to a       |

| reverse power lockout of the main generator. After the SCRAM the 1A RFP      |

| tripped on high water level. Prior to restarting a RFP a second SCRAM signal |

| was received on low level. The Reactor Core Isolation Cooling (RCIC) system  |

| was manually started to restore level while the reactor feed pump was being  |

| restarted. The preliminary investigation indicates that the running lube oil |

| pump on the 1B RFP tripped. The standby lube oil pump started however,       |

| apparently, did not recover lube oil pressure in time to prevent a trip of   |

| 1B RFP."                                                                     |

|                                                                              |

| All control rods properly inserted into the reactor core. The NRC Resident   |

| Inspector was notified.                                                      |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39505       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: HOPE CREEK               REGION:  1  |NOTIFICATION DATE: 01/13/2003|

|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 02:48[EST]|

|   RXTYPE: [1] GE-4                             |EVENT DATE:        01/12/2003|

+------------------------------------------------+EVENT TIME:        23:04[EST]|

| NRC NOTIFIED BY:  RITA BRADDICK                |LAST UPDATE DATE:  01/13/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |RICHARD CONTE        R1      |

|10 CFR SECTION:                                 |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OPEN  DUCTWORK ACCESS PANEL PREVENTED MAINTAINING CONTROL ROOM POSITIVE      |

| PRESSURE                                                                     |

|                                                                              |

| "On January 12, 2003 at 2304, control room pressure was observed to be       |

| negative. At the time the "A" Control Room Emergency Filtration (CREF)       |

| system was tagged out for scheduled maintenance. The event was initiated     |

| when technicians opened an access panel on the "A" CREF control room air     |

| supply duct within the control room boundary to repair a gasket. This        |

| resulted in both "A" and "B" trains of CREF unable to perform its design     |

| safety function: specifically, maintaining the control room at a 1/8 inch    |

| water gauge positive pressure relative to adjacent areas. Without assurance  |

| of CREF system providing positive pressure in the control room, mitigating   |

| the consequences of an accident could have been prevented. Upon discovering  |

| the cause, technicians were ordered to close the access panel. Control room  |

| pressure promptly returned to a normal, positive value. Total time at        |

| negative pressure was ten minutes. No unexpected response was experienced.   |

| In addition to the "A" CREF train, the "A" Hydrogen/Oxygen analyzer was      |

| inoperable at the time of the event."                                        |

|                                                                              |

| The licensee has notified the NRC resident inspector.                        |

+------------------------------------------------------------------------------+

                   