Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for November 27, 2002


                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/26/2002 - 11/27/2002

                              ** EVENT NUMBERS **

39390  39398  39406  39407  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39390       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE: 11/22/2002|
|LICENSEE:  SOUTHERN CALIFORNIA SOIL AND TESTING |NOTIFICATION TIME: 13:03[EST]|
|    CITY:  SAN DIEGO                REGION:  4  |EVENT DATE:        11/21/2002|
|  COUNTY:                            STATE:  CA |EVENT TIME:        09:00[PST]|
|LICENSE#:  3329-37               AGREEMENT:  Y  |LAST UPDATE DATE:  11/22/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DALE POWERS          R4      |
|                                                |DOUG BROADUS         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  HAMRICK                      |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STATE LICENSEE REPORTED A CPN MOISTURE DENSITY GAUGE BEING STOLEN            |
|                                                                              |
|                                                                              |
| State Licensee, Southern California Soil and Testing, Inc. reported that a   |
| CPN MC-3, serial # 360203032, moisture/density gauge was stolen from the     |
| operator's vehicle in San Diego County.  The gauge had been secured to the   |
| bed of the truck using a cable and locks.  The cable was cut in two places   |
| and the gauge was removed.  The operator was unsure of the exact location    |
| where the theft took place.   He made two stops after picking the gauge up   |
| from his office, one at his home for 25 mins and one at a 7/11 store at      |
| 6:45am.   He did not notice the gauge was missing from the back of his truck |
| until an hour later when he checked to see if the gauge had shifted after    |
| braking in traffic.   The gauge contained 10 millicuries of Cs-137 and 50    |
| millicuries of Am-241:Be.  The local law enforcement was notified.           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39398       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NE DIV OF RADIOACTIVE MATERIALS      |NOTIFICATION DATE: 11/22/2002|
|LICENSEE:  BRIAN LGH MEDICAL CENTER             |NOTIFICATION TIME: 16:46[EST]|
|    CITY:  LINCOLN                  REGION:  4  |EVENT DATE:        11/22/2002|
|  COUNTY:                            STATE:  NE |EVENT TIME:        10:30[CST]|
|LICENSE#:  02-06-03              AGREEMENT:  Y  |LAST UPDATE DATE:  11/22/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DALE POWERS          R4      |
|                                                |C.W. (BILL) REAMER   NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BRENT FRIESEN                |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MISSING 5 MILLICURIE STRONTIUM-90 SOURCE.                                    |
|                                                                              |
| The Radiation Safety Officer for Brian LGH Medical Center located at 1300    |
| South 16th Street in Lincoln, NE, noticed at 1030 CST on 11/22/02 that a     |
| source was missing from a Novoste Beta Cath System source holder.  The       |
| source holder holds 16 sources of strontium-90, each source is 5             |
| millicuries, and one of the sources was found missing.  A search of the      |
| device and of the lab did not find the missing source.  The RSO contacted    |
| the manufacturer.  The last time the Novoste Beta Cath System was used was   |
| November 13, 2002.                                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39406       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 11/26/2002|
|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 08:24[EST]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        11/26/2002|
+------------------------------------------------+EVENT TIME:        03:42[CST]|
| NRC NOTIFIED BY:  BRUCE FRANZEN                |LAST UPDATE DATE:  11/26/2002|
|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES CREED          R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       97       Power Operation  |97       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 2 HPCI SYSTEM DECLARED INOPERABLE                                       |
|                                                                              |
| Unit 2 HPCI (High Pressure Coolant Injection) system was declared inoperable |
| at 0342 [CST] due to a failed relay for the MGU (Motor Gear Unit) flow       |
| control circuit.  The relay is normally energized when the MGU is at the     |
| High Speed Stop and is utilized to de-energize the motor gear unit when a    |
| limit switch is reached to prevent damage to the MGU motor.  The resultant   |
| failure affects HPCI such that the MGU will not function from a signal       |
| generated by the Flow Indicating Controller.  HPCI can be operated manually  |
| from [the] Control Room.                                                     |
|                                                                              |
| The Resident Inspector was notified of this event.                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39407       |
+------------------------------------------------------------------------------+
!!!!!!!!                    This Event is not Available                  !!!!!!!
!!!     for public disclosure per Agreement State request until 11/29/02   !!!
+------------------------------------------------------------------------------+
| REP ORG:  GEORGIA RADIOACTIVE MATERIAL PGM     |NOTIFICATION DATE: 11/26/2002|
|LICENSEE:  GEORGIA DEPT. OF TRANSPORTATION      |NOTIFICATION TIME: 14:02[EST]|
|    CITY:  TIFTON                   REGION:  2  |EVENT DATE:        11/25/2002|
|  COUNTY:                            STATE:  GA |EVENT TIME:        14:30[EST]|
|LICENSE#:  GA 50-1               AGREEMENT:  Y  |LAST UPDATE DATE:  11/26/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CAROLYN EVANS        R2      |
|                                                |THOMAS ESSIG         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  THOMAS E. HILL               |                             |
|  HQ OPS OFFICER:  JASON FLEMMING               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE NOTIFICATION - DAMAGE TO TROXLER MOISTURE DENSITY GAUGE      |
|                                                                              |
| "While a back scatter measurement was being taken in a closed lane of        |
| Interstate 75 southbound a tractor-trailer swerved to avoid another vehicle, |
| struck the gauge damaging it. Based on field measurements there is no        |
| evidence of the sources being breached or leaking, no contamination          |
| identified. Source was separated from the source rod. The gauge has been     |
| recovered and returned to the [Georgia] DOT [Department of Transportation]   |
| headquarters office. This is all that is known about the incident at this    |
| time."                                                                       |
|                                                                              |
| The gauge contained 10 millicuries of Cs -137 and 40 millicuries of Am-241   |
+------------------------------------------------------------------------------+



Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021