Event Notification Report for October 30, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
10/29/2002 - 10/30/2002
** EVENT NUMBERS **
39238 39326 39330
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39238 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DAVIS BESSE REGION: 3 |NOTIFICATION DATE: 10/02/2002|
| UNIT: [1] [] [] STATE: OH |NOTIFICATION TIME: 14:20[EDT]|
| RXTYPE: [1] B&W-R-LP |EVENT DATE: 10/02/2002|
+------------------------------------------------+EVENT TIME: 13:44[EDT]|
| NRC NOTIFIED BY: ART LEWIS |LAST UPDATE DATE: 10/29/2002|
| HQ OPS OFFICER: MIKE NORRIS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |SONIA BURGESS R3 |
|10 CFR SECTION: |JOHN DAVIDSON IAT |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION |TERRY REIS NRR |
|DDDD 73.71(b)(1) SAFEGUARDS REPORTS |BETH HAYDEN OPA |
| |SCOTT MORRIS EDO |
| |TIM MCGINTY IRO |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 1 HOUR SAFEGUARDS REPORT |
| |
| Attempted introduction of contraband into controlled access area. |
| |
| The NRC Resident Inspector was notified. |
| |
| Contact Headquarters Operations Officer for additional details. |
| |
| *** UPDATE ON 10/29/02 AT 1256ET BY AARON BLESS TAKEN BY MACKINNON**** |
| |
| "After further review of our procedures and the regulatory requirements of |
| 10 CFR 73 Appendix G the licensee has determined the issue of the contraband |
| which was discovered .. .. Located a significant distance from the |
| protected area, on October 2, 2002, to be not reportable. All information |
| was provided expeditiously to the NRC Operation Center during and after the |
| discovery of the contraband , however the event notification is being |
| rescinded due to the fact that the contraband was never introduced or |
| attempted to be introduced into the protected area, material access area, |
| vital area, or transport. The NRC Security Safeguards Staff of Region III |
| has been informed of the plans to rescind the event notification." R3DO |
| (Jim Creed) notified. |
| |
| "The NRC Resident Inspector has been notified of the update." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39326 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PERRY REGION: 3 |NOTIFICATION DATE: 10/29/2002|
| UNIT: [1] [] [] STATE: OH |NOTIFICATION TIME: 03:26[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 10/28/2002|
+------------------------------------------------+EVENT TIME: 23:15[EDT]|
| NRC NOTIFIED BY: JIM CASE |LAST UPDATE DATE: 10/29/2002|
| HQ OPS OFFICER: RICH LAURA +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |JAMES CREED R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DAMAGED CONTROL ROOM DOOR SEAL |
| |
| "Declared both trains of Control Room Emergency Recirc inoperable, entered |
| Tech Spec 3.0.3 from Tech Spec 3.7.3 on loss of Control Room boundary. A |
| damaged door seal leading from the Control Complex to the Service building |
| caused the loss of the Control room boundary. Door was closed and |
| temporarily sealed per SOI-M25/26. Exited Tech Spec 3.0.3 at 00:15 on |
| 10/29/02." |
| |
| The NRC Resident Inspector was notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39330 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 10/29/2002|
| UNIT: [1] [2] [] STATE: WI |NOTIFICATION TIME: 18:11[EST]|
| RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 10/29/2002|
+------------------------------------------------+EVENT TIME: 10:25[CDT]|
| NRC NOTIFIED BY: MIKE HOLTZMANN |LAST UPDATE DATE: 10/29/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |JAMES CREED R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AUXILIARY FEEDWATER SYSTEM (AFWS) DECLARED INOPERABLE |
| |
| "At 10:27 CST, the auxiliary feedwater system (AFWS) for Point Beach Nuclear |
| Plant, Units 1 and 2, was declared inoperable due to the potential for |
| fouling of the minimum recirculation orifices for each of the four AFW |
| pumps. The mechanism identified was the potential for foreign materials in |
| the AFW fluid restricting adequate flow through the flow control orifices in |
| the recirculation line. Under such conditions, it is possible that if the |
| discharge valves for the AFW pumps are throttled, adequate flow may be |
| unavailable through the recirculation line and pump damage could occur. |
| |
| "The potential for this common failure mode was realized while conducting an |
| extent-of-condition evaluation for reduced recirculation flow observed |
| during surveillance testing of the P-38A motor driven AFW pump on October |
| 24, 2002. The flow was less than expected but above the minimum required |
| for pump operability. Upon disassembly of the P-38A flow orifice we |
| discovered a build up of corrosion products in the orifice. |
| |
| "Both units entered Tech Spec [Action Condition] 3.7.5.E and required action |
| 3.7.5.E.1 which requires immediate steps to restore an AFWS to operable |
| status. Immediate corrective actions have consisted of briefing the |
| on-shift crew (on-coming crews will also be briefed) of the potential |
| consequences of restricted recirculation flow and directing the operators, |
| in the event of a situation requiring AFW flow, to secure a running AFW pump |
| if the pump discharge falls below minimum flow requirements. In addition, |
| information tags have been attached by the AFW pump flow indicators on the |
| main control boards to convey that information. These action were completed |
| at 1305 CST. At that time, with these administrative controls in place, we |
| declared the AFWS back in service. Longer term corrective actions, |
| including permanent procedure changes, are being evaluated." |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+