The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for October 28, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
10/25/2002 - 10/28/2002
** EVENT NUMBERS **
39313 39314 39321 39322
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39313 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NC DIV OF RADIATION PROTECTION |NOTIFICATION DATE: 10/23/2002|
|LICENSEE: FORSYTH MEDICAL CENTER |NOTIFICATION TIME: 16:40[EDT]|
| CITY: WINSTON-SALEM REGION: 2 |EVENT DATE: 10/23/2002|
| COUNTY: STATE: NC |EVENT TIME: 15:00[EDT]|
|LICENSE#: NC 034-0878-3 AGREEMENT: Y |LAST UPDATE DATE: 10/23/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |ROBERT HAAG R2 |
| |MELVYN LEACH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES ALBRIGHT | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STUCK SOURCE IN BRACHYTHERAPY DELIVERY SYSTEM |
| |
| North Carolina Incident Report #02-40. While performing a QA/QC test of a |
| Gamma Med Brachytherapy system, the source (unknown strength at this time) |
| stuck half way out. Efforts to retrieve the source normally, with the |
| emergency retrieval system, and the manual crank were not successful. The |
| manufacturer has been notified and the area secured. One physicist entered |
| the room during the recovery operation and may have received a dose, survey |
| meter pegged at 2 Rem/hour on entry to room. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39314 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NC DIV OF RADIATION PROTECTION |NOTIFICATION DATE: 10/23/2002|
|LICENSEE: PRIZM LABS |NOTIFICATION TIME: 17:09[EDT]|
| CITY: CHARLOTTE REGION: 2 |EVENT DATE: 10/14/2002|
| COUNTY: STATE: NC |EVENT TIME: [EDT]|
|LICENSE#: NC 1203-0G AGREEMENT: Y |LAST UPDATE DATE: 10/23/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |ROBERT HAAG R2 |
| |MELVYN LEACH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES ALBRIGHT | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - LEAKING SEALED SOURCE |
| |
| North Carolina Incident Report #02-41. Reported to North Carolina Division |
| of Radiation Protection on 10/23/02 that an electron capture device sealed |
| source (20 millicuries of Ni-63, serial #5339) has been determined to be |
| leaking. Smear read 180,000 DPM (0.08 microcuries). Prizm Labs is |
| contacting the manufacturer for disposal. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39321 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: ARKANSAS NUCLEAR REGION: 4 |NOTIFICATION DATE: 10/25/2002|
| UNIT: [1] [] [] STATE: AR |NOTIFICATION TIME: 04:43[EDT]|
| RXTYPE: [1] B&W-L-LP,[2] CE |EVENT DATE: 10/24/2002|
+------------------------------------------------+EVENT TIME: 20:52[CDT]|
| NRC NOTIFIED BY: DAVID THOMPSON |LAST UPDATE DATE: 10/25/2002|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |ANTHONY GODY R4 |
|10 CFR SECTION: | |
|AMED 50.72(b)(3)(xii) OFFSITE MEDICAL | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONTAMINATED WORKER TRANSPORTED OFFSITE FOR MEDICAL TREATMENT |
| |
| "While working under the ANO-1 Reactor Vessel Head, an individual bumped his |
| head on a Control Rod Drive Lead Screw. The contact resulted in a 1-inch |
| laceration on the side of the head. The Emergency Medical Response Team was |
| activated and responded to the scene. The Individual was conscious but |
| dazed. An initial survey for contamination was performed and was |
| inconclusive due to background levels at the scene and due to a head brace |
| which was placed on the individual as a precaution to guard against neck |
| injury. An ambulance was called to the site and the individual was |
| transported with a ANO Health Physicist to Saint Mary's Regional Medical |
| Center. Additional surveying of the individual revealed that the |
| individuals head was slightly contaminated at approximately 100 counts per |
| minute above background and the backboard used in transport had |
| approximately 150 counts per minute. The individual was decontaminated by |
| ANO Health Physics personnel dispatched to the hospital. All of the |
| radioactive material was retrieved and returned to the site. The individual |
| is in satisfactory condition and the wound required 3 stitches to close." |
| |
| The licensee will inform the state and has informed the NRC resident |
| inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 39322 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: US AIR FORCE |NOTIFICATION DATE: 10/25/2002|
|LICENSEE: US AIR FORCE |NOTIFICATION TIME: 09:15[EDT]|
| CITY: WASHINGTON REGION: 1 |EVENT DATE: 10/24/2002|
| COUNTY: STATE: DC |EVENT TIME: 11:00[EDT]|
|LICENSE#: 42-23539-01 AGREEMENT: N |LAST UPDATE DATE: 10/25/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |ANTHONY GODY R4 |
| |CHRISTINE LIPA R3 |
+------------------------------------------------+FRED BROWN NMSS |
| NRC NOTIFIED BY: PUGH | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|ICON 30.50(b)(1) UNPLANNED CONTAMINATION| |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNPLANNED CONTAMINATION OF AN INDIVIDUAL AFTER BREAKING A VIAL CONTAINING |
| TRITIUM FROM AN EXIT SIGN. |
| |
| An individual at the Wright Patterson Air Force Base was working in a 40' x |
| 40' rad storage facility when a glass vial from an exit sign(sealed source |
| and device #NY-594-D-102-D) slipped out of its protective plastic cover and |
| broke after hitting the floor. The vial contained approximately 3.226 |
| curies of tritium(calculated activity) which is less than he original |
| activity of 10 curies. The highest reading measured in the room from |
| surveys and swipes was 60,000 cpm. After initial wipe downs with wet rags, |
| contamination was reduced in that area to 800 cpm. They will continue to |
| survey and when contamination is found will continue to decontaminate until |
| acceptable release criteria is obtained. |
| |
| The gentleman that was in the room when the vial broke and release occurred |
| is having a bioassay and an estimate his whole body exposure is between |
| 11-12 mrem. He and a second person are performing the surveys and |
| decontamination of the room. The second individual will also probably get a |
| bioassay upon completion of decon. |
+------------------------------------------------------------------------------+