The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for October 21, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
10/18/2002 - 10/21/2002
** EVENT NUMBERS **
39285 39289 39290 39293 39301 39302 39303 39304 39305
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39285 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 10/15/2002|
|LICENSEE: BAYLOR ALL SAINTS MED CENTER, MEDI-PH|NOTIFICATION TIME: 11:35[EDT]|
| CITY: FORT WORTH, DALLAS REGION: 4 |EVENT DATE: 09/25/2002|
| COUNTY: STATE: TX |EVENT TIME: 11:30[CDT]|
|LICENSE#: L2212, L05529 AGREEMENT: Y |LAST UPDATE DATE: 10/15/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |WAYNE HODGES NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: HELEN WATKINS | |
| HQ OPS OFFICER: MIKE RIPLEY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PERSONNEL CONTAMINATION AND EXCESSIVE PACKAGE LEVELS AT NUCLEAR MEDICINE |
| FACILITIES |
| |
| "A 300 millicurie multidose glass vial of technetium-99m was dropped on the |
| floor at about 11:30 am [September 25, 2002] in a hot lab area at Baylor by |
| a nuclear medicine technologist. About 40% of the vial contents spilled on |
| the tech's pants, legs, and shoes. The initial radiation reading on the |
| tech's clothing was 35.2 [millirem]/hr. An initial wipe test of the floor |
| gave a reading of 81,012 dpm. The floor was decontaminated using radiowash |
| until radiation wipe levels were at 366 dpm and the survey meter detected |
| 1.8 [millirem]/hr. The tech's clothing were placed in storage for decay. |
| |
| "An outgoing nuclear medicine ammo box was about three feet from the spill. |
| The box was labeled and had been surveyed and was ready for pickup by the |
| nuclear pharmacy, Medi-Physics. The technologist did not believe the spill |
| had contaminated the ammo box and did not perform an additional survey of |
| it. The ammo box was picked up by a courier for the nuclear pharmacy. The |
| courier picked up the ammo box by using the keypad lock to access the |
| unoccupied hot lab as was his normal routine. |
| |
| "At around 1:00pm, as the courier was leaving the Medi-Physics facility, he |
| surveyed his hands and noticed radiation readings. Both palms were |
| contaminated and so was his shirt and pants. The hands gave readings of 8340 |
| cpm's. The courier was decontaminated to approximate background levels. The |
| only package picked up and transported by the courier was the ammo box from |
| Baylor. The nuclear pharmacy contacted Baylor and notified the State. |
| |
| "The ammo box radiation readings were 2,664,800 cpm's and the main area of |
| contamination read 150 [millirem]/hr. The courier vehicle showed |
| contamination on the door handle, radio knob, steering wheel, and gear |
| shift. Radiation readings were in the range of 81,649 cpm's. The ammo box |
| was placed in storage for decay. The vehicle was quarantined, decontaminated |
| to background revels, and returned to service the following day. |
| |
| "Additional information will be provided to the Agency in the Licensee's |
| written report. An onsite investigation by the Texas Department of Health |
| Bureau of Radiation Control identified items of noncompliance with Agency |
| regulations." |
| |
| Texas Incident No. I-7938 |
| |
| Medi-Physics, Inc (doing business as Amersham Health of Dallas) Dallas, TX |
| - License No. L05529 |
| BaylorAll Saints Med Center, Ft. Worth, TX - License No. L02212 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39289 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ARIZONA RADIATION REGULATORY AGENCY |NOTIFICATION DATE: 10/15/2002|
|LICENSEE: CONSTRUCTION INSPECTION AND TESTING |NOTIFICATION TIME: 19:18[EDT]|
| CITY: TEMPE REGION: 4 |EVENT DATE: 10/15/2002|
| COUNTY: STATE: AZ |EVENT TIME: 15:25[MST]|
|LICENSE#: 7-98 AGREEMENT: Y |LAST UPDATE DATE: 10/15/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |M. WAYNE HODGES NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: AZ RAD REGULATORY AGENCY | |
| HQ OPS OFFICER: GERRY WAIG | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE - LOST OR STOLEN TROXLER MOISTURE DENSITY GAUGE |
| |
| "Description of event: The licensee reported the loss of a Troxler |
| moisture/density gauge sometime between 1030 and 1115 on 15 October after |
| the technician left a job site in the vicinity of Cactus and 151st Ave. The |
| gauge had been in the back of a pickup with the tailgate down. The gauge did |
| not have a handle lock. A search of his route for several hours failed to |
| turn up the gauge. The gauge is a Troxler Model 3400 series, serial number |
| 29519. It contains approximately 10 millicuries of cesium 137 and |
| approximately 50 millicuries of americium-beryllium. The company is offering |
| a $250 reward for information leading to the return of the gauge and truck. |
| |
| "The U.S. NRC, FBI, Mexico, and the states of Colorado, Nevada, Utah, New |
| Mexico and California are being informed of this incident." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39290 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: COLORADO DEPT OF HEALTH |NOTIFICATION DATE: 10/15/2002|
|LICENSEE: MIDWEST INSPECTION SERVICES |NOTIFICATION TIME: 19:15[EDT]|
| CITY: DENVER REGION: 4 |EVENT DATE: 10/14/2002|
| COUNTY: STATE: CO |EVENT TIME: [MDT]|
|LICENSE#: CO 902-01 AGREEMENT: Y |LAST UPDATE DATE: 10/15/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |M. WAYNE HODGES NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TIM BONZER (VIA FAX) | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING INDUSTRIAL RADIOGRAPHY INCIDENT |
| |
| The following information was documented as a telecon "to file" received by |
| State of Colorado staff: |
| |
| "Received phone notification today from Jeff Conners at Midwest Inspection |
| Services concerning a source disconnect incident that happened yesterday, |
| 10/14/02. Mr. Conners reported a radiography crew, working at a field site |
| north of Denver, was unable to retract an Iridium-192 radiography source |
| back into the camera. The radiographers called Mr. Conners, who is the |
| assistant Radiation Safety Officer, for help. Mr. Conners reported that he |
| responded to the scene and was successful in connecting the source assembly |
| to the drive cable and retracting it back into the radiography camera. He |
| also responded that there were no overexposures to the radiography crew or |
| members of the public. Mr. Conners estimated his exposure for the recovery |
| operation to be about 500 millirem, based on his pocket dosimeter readings. |
| He stated that he would send a detailed written report to the Department |
| within 30 days. The corporate RSO, David Ezell, was also notified of the |
| incident." |
| |
| Contact the Headquarters Operations Officer for additional information. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39293 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: OR DEPT OF HEALTH RAD PROTECTION |NOTIFICATION DATE: 10/16/2002|
|LICENSEE: GEOCON NORTHWEST INC |NOTIFICATION TIME: 14:04[EDT]|
| CITY: BEAVERTON REGION: 4 |EVENT DATE: 10/16/2002|
| COUNTY: STATE: OR |EVENT TIME: [PDT]|
|LICENSE#: ORE-90921 AGREEMENT: Y |LAST UPDATE DATE: 10/16/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |THOMAS ESSIG NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TERRY LINDSEY | |
| HQ OPS OFFICER: GERRY WAIG | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| STOLEN VEHICLE AND TROXLER MOISTURE DENSITY GAUGE |
| |
| On the evening 10/15/02 or the early morning of 10/16/02 a 1987 red Toyota 4 |
| Runner storing a Troxler moisture density gauge was stolen from the |
| residence of an authorized user. The local police were notified of the theft |
| at approximately 0800 PDT and the Oregon Radiation Protection Services at |
| 0855 PDT on 10/16/02. The gauge is a Troxler model 3440 serial number 26707 |
| and contains an 8 millicurie Cs-137 source, serial number 75-9841, and a 40 |
| millicurie Am-241:Be source, serial number 47-23181. The licensee is GEOCON |
| Northwest Inc., 8380 Southwest Ave., Beaverton, OR 97008. Oregon Radiation |
| Protection Services will notify NRC Region 4 and plans to make a press |
| release for this event. The Oregon event number for this incident is 020041. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 39301 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 10/17/2002|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 23:30[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 10/17/2002|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 16:40[CDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 10/18/2002|
| CITY: PADUCAH REGION: 3 +-----------------------------+
| COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION |
|LICENSE#: GDP-1 AGREEMENT: Y |THOMAS KOZAK R3 |
| DOCKET: 0707001 |M. WAYNE HODGES NMSS |
+------------------------------------------------+NADER MAMISH IRO |
| NRC NOTIFIED BY: K. A. BEASLEY | |
| HQ OPS OFFICER: ARLON COSTA | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NBNL RESPONSE-BULLETIN | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 24-HOUR 91-01 BULLETIN RESPONSE NOTIFICATION |
| |
| "At 1708 on 10-17-02, the Plant Shift Superintendent (PSS) was notified that |
| potentially fissile (PF) waste had been discovered improperly stored at the |
| Wet Air Pump station in the C-333 building. A pile of used absorbent pads |
| was found in the floor at the West Air station. The absorbent pads are used |
| to soak up oil that has leaked from the pumps. These pads should have been |
| placed in an AQ-NCS approved 5.5 gallon drum and controlled as PF waste as |
| they were picked up. This is a violation of the requirements of NCSA |
| GEN-15. |
| |
| "The NRC Resident inspector has been notified of this event. |
| |
| "SAFETY SIGNIFICANCE OF EVENTS: The used absorbent pads were accumulated |
| incorrectly; however the uranium concentration for heterogeneous waste is |
| low and a large quantity of heterogeneous fissile material would be required |
| for a criticality to occur. |
| |
| "PATHWAYS INVOLVED: In order for a criticality to be possible, the |
| interaction process condition would also have to be violated. However, the |
| interaction control was maintained and therefore a criticality was not |
| possible. |
| |
| "CONTROLLED PARAMETERS: The two process conditions relied upon for double |
| contingency for this scenario are interaction and geometry. |
| |
| "NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEMS(S) AND DESCRIPTION |
| OF THE FAILURES OR DEFICIENCIES: The first leg of double contingency is |
| based on a minimum 2 ft. edge-to-edge spacing requirement to ensure double |
| contingency for spacing violations involving waste drums end other items |
| containing fissile/potentially fissile material. This control was not |
| violated. |
| |
| "The second leg of double contingency is based on geometry controls of the |
| waste when it is placed into an AQ-NCS approved waste drum and the secondary |
| containment pans used to store the drums. Since the waste was accumulated on |
| the floor and not into the NCS-approved container, this control was |
| violated. The process condition was not maintained and double contingency |
| was not maintained |
| |
| "Since the used absorbent pads were not generated into an AQ-NCS approved |
| waste container, the process condition for waste accumulation was not |
| maintained. Therefore, double contingency was not maintained. |
| |
| "CORRECTIVE ACTIONS: A buffer area has been established to control movement |
| of fissile material within the area. A remediation guide will be prepared by |
| NCS prior to removal of the used absorbent pads. |
| |
| *****UPDATE ON 10/18/02 AT 2120 FROM BEASLEY TO LAURA***** |
| |
| "As a result of continued evaluation, it was discovered that the pile of |
| absorbent pads was with 2 feet of the 4 inch diameter wet air header. |
| Therefore the minimum 2-foot spacing control has also been violated. Even |
| though the spacing control was violated, the existing configuration is |
| bounded by analysis, and it is acceptable to continue to use the header |
| piping within 2-feet of the pile of absorbent pads. |
| |
| "While approved analysis does exist to safely bound the current violation |
| configuration, both controls relied upon for the safe generation and |
| handling of potentially fissile waste material were violated. |
| |
| "In order for a criticality to be possible, an additional violation would |
| have to occur resulting in an unsafe mass of fissile material accumulating |
| in an unsafe geometry. |
| |
| "Approved analysis exists which bounds the existing configuration and |
| demonstrates it is subcritical. However, the process conditions for waste |
| accumulation were not maintained. Therefore, double contingency was not |
| maintained." |
| |
| Notified NMSS (HODGES). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 39302 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: US ARMY |NOTIFICATION DATE: 10/18/2002|
|LICENSEE: US ARMY |NOTIFICATION TIME: 09:52[EDT]|
| CITY: FT BRAGG REGION: 2 |EVENT DATE: 10/17/2002|
| COUNTY: STATE: NC |EVENT TIME: [EDT]|
|LICENSE#: 19-30563-01 AGREEMENT: Y |LAST UPDATE DATE: 10/18/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |KEN BARR R2 |
| | |
+------------------------------------------------+ |
| NRC NOTIFIED BY: KUYKENDALL | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|BLO2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| POSSIBLE LOST/STOLEN CHEMICAL AGENT DETECTOR |
| |
| The licensee is investigating the circumstances involving a chemical agent |
| detector being turned in to the Military Police (MP's) by the spouse of a |
| serviceman stationed at Fort Bragg NC. The CAD, containing 15 millicuries |
| of Ni-63, was being kept at the serviceman's home. The Army is trying to |
| determine if the device was stolen . |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39303 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: QUAD CITIES REGION: 3 |NOTIFICATION DATE: 10/19/2002|
| UNIT: [1] [] [] STATE: IL |NOTIFICATION TIME: 05:27[EDT]|
| RXTYPE: [1] GE-3,[2] GE-3 |EVENT DATE: 10/18/2002|
+------------------------------------------------+EVENT TIME: 21:30[CDT]|
| NRC NOTIFIED BY: JOHN LECHMAIER |LAST UPDATE DATE: 10/19/2002|
| HQ OPS OFFICER: MIKE NORRIS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |THOMAS KOZAK R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| RCIC HIGH STEAM FLOW ISOLATION INSTRUMENTATION INOPERABLE DUE TO BEING OUT |
| OF TOLERANCE |
| |
| "At 2130 hours CDT on 10/18/2002, the U1 RCIC High Steam Flow Isolation |
| Instrumentation was determined to have been inoperable. Both U1 RCIC High |
| Steam Flow switches were found to be outside their Technical Specification |
| Allowable Value during a calibration surveillance. Both U1 RCIC High Steam |
| Flow switches were subsequently recalibrated back to within their Technical |
| Specification Allowable Value. |
| |
| "This notification is being made in accordance with 10CFR50.72(b)(3)." |
| |
| The NRC Resident Inspector has been notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39304 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FERMI REGION: 3 |NOTIFICATION DATE: 10/19/2002|
| UNIT: [2] [] [] STATE: MI |NOTIFICATION TIME: 11:55[EDT]|
| RXTYPE: [2] GE-4 |EVENT DATE: 10/19/2002|
+------------------------------------------------+EVENT TIME: 10:15[EDT]|
| NRC NOTIFIED BY: JEFF GROFF |LAST UPDATE DATE: 10/19/2002|
| HQ OPS OFFICER: MIKE NORRIS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |THOMAS KOZAK R3 |
|10 CFR SECTION: | |
|ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF ENS AND COMMERCIAL TELECOMMUNICATIONS |
| |
| "At 10:15 on 10/19/02, the ENS and commercial telecommunications capability |
| to dial offsite was found to be non-functioning. Communications to outside |
| agencies have been verified using the microwave lines (RERP lines). The |
| cause of the problem is not yet determined, however, the local |
| telecommunications company is investigating." |
| |
| The NRC Resident Inspector was notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39305 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE REGION: 1 |NOTIFICATION DATE: 10/19/2002|
| UNIT: [] [2] [] STATE: CT |NOTIFICATION TIME: 14:14[EDT]|
| RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP |EVENT DATE: 10/19/2002|
+------------------------------------------------+EVENT TIME: 13:47[EDT]|
| NRC NOTIFIED BY: BARRY DOE |LAST UPDATE DATE: 10/19/2002|
| HQ OPS OFFICER: ARLON COSTA +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |KENNETH JENISON R1 |
|10 CFR SECTION: | |
|ASHU 50.72(b)(2)(i) PLANT S/D REQD BY TS | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |99 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TECH SPEC REQUIRED SHUTDOWN |
| |
| "Millstone U2 Initiation of plant shutdown as required by Technical |
| Specifications 10CFR50(b)(2)(i)" |
| |
| Power supply to the Engineering Safeguards Activation System was replaced |
| and tested satisfactory. Unit will subsequently return back to full power. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021