Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for October 17, 2002



                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           10/16/2002 - 10/17/2002

                              ** EVENT NUMBERS **

39273  39284  39291  39292  39294  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39273       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE: 10/11/2002|
|LICENSEE:                                       |NOTIFICATION TIME: 18:10[EDT]|
|    CITY:  LOS ANGLELES             REGION:  4  |EVENT DATE:        10/10/2002|
|  COUNTY:                            STATE:  CA |EVENT TIME:             [PDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  10/11/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |KRISS KENNEDY        R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  KATHLEEN KAUFMAN             |                             |
|  HQ OPS OFFICER:  GERRY WAIG                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT: LOST OR STOLEN GERMANIUM 68 SOURCE                   |
|                                                                              |
| A 10 millicurie Germanium 68 source was lost or stolen while in shipment by  |
| Federal Express (Fed Ex) from Cedar Rapids, IA to Burbank, CA. Fed Ex is     |
| attempting to locate the missing source. The State of California event       |
| number for this event is 101102.                                             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39284       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  LOUISIANA RADIATION PROTECTION DIV   |NOTIFICATION DATE: 10/14/2002|
|LICENSEE:  SCHLUMBERGER TECHNOLOGY CORP         |NOTIFICATION TIME: 16:27[EDT]|
|    CITY:  CAMERON                  REGION:  4  |EVENT DATE:        10/12/2002|
|  COUNTY:                            STATE:  LA |EVENT TIME:             [CDT]|
|LICENSE#:  LA-2783-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  10/14/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |KRISS KENNEDY        R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  SCOTT BLACKWELL (email)      |                             |
|  HQ OPS OFFICER:  GERRY WAIG                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE - IRRETRIEVABLE WELL LOGGING SOURCE                          |
|                                                                              |
| "Agreement State Agency: Louisiana Department of Environmental Quality       |
|                                                                              |
| "Event Report ID No.: LA020013                                               |
|                                                                              |
| "License No.: LA-2783-L01                                                    |
|                                                                              |
| "Licensee: Schlumberger Technology Corp                                      |
|                                                                              |
| "Event date and Time: October 12, 2002                                       |
|                                                                              |
| "Event Location: Miami Corp #1S in Cameron, LA                               |
|                                                                              |
| "Event type: Irretrievable Well Logging Source                               |
|                                                                              |
| "Notifications: Schlumberger notified the Louisiana Department of Natural    |
| Resources and the Louisiana Department of Environmental Quality.             |
|                                                                              |
| "Event description:                                                          |
|                                                                              |
| On October 9, 2002, a well logging tool was stuck down hole. The tool        |
| contained a 1.7 Ci source of Cs-137 model number GSRZ with s/n 2009 and a 16 |
| Ci source of Am241Be model number NSR-L with s/n 3068. There were repeated   |
| attempts to retrieve the tool. On October 12, 2002, it was decided to        |
| abandon the tool. Approval was given from the state of Louisiana on October  |
| 12, 2002, to abandon the tool. The approximate depth of the tool is 10,822   |
| feet.  A cement plug was going to be placed above the tool, cement is going  |
| to be added around the tool, and an upside down drill bit is to be used as a |
| deflection device."                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39291       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY                   REGION:  2  |NOTIFICATION DATE: 10/16/2002|
|    UNIT:  [1] [] []                 STATE:  AL |NOTIFICATION TIME: 01:45[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        10/15/2002|
+------------------------------------------------+EVENT TIME:        23:56[CDT]|
| NRC NOTIFIED BY:  JIM HUNTER                   |LAST UPDATE DATE:  10/16/2002|
|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |KEN BARR             R2      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     M/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL REACTOR TRIP DUE TO DROPPED ROD                                       |
|                                                                              |
| "The Unit 1 Operator-At-The-Controls moved control rod bank D rods in 1/2    |
| step for routine flux control at 2353 on 10/15/02.  He immediately noticed   |
| rod F-6 indicated 198 steps.  The remainder of the rods in bank D indicated  |
| 221 steps.  A negative rate trip was received on Excore Nuclear Instrument   |
| N43 and reactor power decreased approximately 1/2% RTP [rated thermal        |
| power].  A manual reactor trip was initiated at 2356 in accordance with      |
| Abnormal Operating Procedure FNP-1-AOP-19.0.  All plant systems responded    |
| per design to the reactor trip.  The plant is currently stable in Mode 3.    |
| The cause for the rod drop is being investigated.  Both motor driven         |
| auxiliary feedwater pumps and the turbine driven auxiliary feedwater pumps   |
| auto started in response to the main steam generator feed pumps trip."       |
|                                                                              |
| All rods fully inserted into the core.  The Main Condenser is being          |
| maintained as the primary heat sink.                                         |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39292       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAN ONOFRE               REGION:  4  |NOTIFICATION DATE: 10/16/2002|
|    UNIT:  [] [] [3]                 STATE:  CA |NOTIFICATION TIME: 12:02[EDT]|
|   RXTYPE: [1] W-3-LP,[2] CE,[3] CE             |EVENT DATE:        10/16/2002|
+------------------------------------------------+EVENT TIME:        01:52[PDT]|
| NRC NOTIFIED BY:  GEOFFREY COOK                |LAST UPDATE DATE:  10/16/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |GREG PICK            R4      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          Y       100      Power Operation  |75       Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL ACTUATION OF THE EMERGENCY FEEDWATER SYSTEM                           |
|                                                                              |
| "On October 16, 2002 at about 0150 PDT, to test the normal lube oil system   |
| for Unit 3 normal feedwater pump K006, plant operators started the second    |
| (3P-109) of the two lube oil pumps for normal feedwater pump K006 at San     |
| Onofre Unit 3. For this test, after normal operation of the second pump has  |
| been observed, the first lube oil pump (3P-122) is stopped. At 0152 PDT, the |
| first lube oil pump (3P-122) was manually stopped by plant operators and     |
| normal feedwater pump K006 automatically tripped. Because 100 percent power  |
| operation cannot be sustained with only one of the two normal feedwater      |
| pumps in operation, plant operators began reducing reactor power level to    |
| about 75 percent. As specified by plant procedures as a precautionary        |
| measure, plant operators also manually initiated the Emergency Feedwater     |
| system, which successfully started all three emergency feed water pumps.     |
| Because 10CFR50.72(b)(3)(iv)(A) requires licensees to report any event or    |
| condition that results in valid actuation of the emergency feedwater system, |
| SCE is providing this notification to the NRC.                               |
|                                                                              |
| "The cause of this event is currently under investigation and will be        |
| reported to the NRC in the required follow-up 60-day written report.         |
|                                                                              |
| "At the time of this occurrence, both Units 2 and 3 were operating at about  |
| 100 percent power.                                                           |
|                                                                              |
| "SCE has notified the NRC resident inspectors about this occurrence and will |
| provide them with a copy of this report."                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39294       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 10/16/2002|
|    UNIT:  [1] [2] []                STATE:  MD |NOTIFICATION TIME: 16:35[EDT]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        10/16/2002|
+------------------------------------------------+EVENT TIME:        15:25[EDT]|
| NRC NOTIFIED BY:  DAVID FRYE                   |LAST UPDATE DATE:  10/16/2002|
|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |KENNETH JENISON      R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 4 HOUR OFFSITE NOTIFICATION TO MD DEPARTMENT OF ENVIRONMENT                  |
|                                                                              |
| "Calvert Cliffs made a report to the  Maryland Department of the Environment |
| for positive coliform bacteria in the [potable water for the] office         |
| facilities."                                                                 |
|                                                                              |
| The NRC Resident Inspector will be notified by the Licensee.                 |
+------------------------------------------------------------------------------+