Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for September 27, 2002


                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/26/2002 - 09/27/2002

                              ** EVENT NUMBERS **

39210  39213  39218  39219  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39210       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  OK DEQ RAD MANAGEMENT                |NOTIFICATION DATE: 09/23/2002|
|LICENSEE:  APAC                                 |NOTIFICATION TIME: 10:47[EDT]|
|    CITY:  OKLAHOMA CITY            REGION:  4  |EVENT DATE:        09/21/2002|
|  COUNTY:                            STATE:  OK |EVENT TIME:        02:30[CDT]|
|LICENSE#:  OK26937-01            AGREEMENT:  Y  |LAST UPDATE DATE:  09/24/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN PELLET          R4      |
|                                                |DOUG BROADDUS        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MIKE BRODERICK               |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE                               |
|                                                                              |
| The licensee reported to the State of Oklahoma that on Friday night that one |
| of their trucks was proceeding south on I-35 near 4th St. in Moore, OK when  |
| a Troxler gauge was bounced out of the bed of the truck.  The gauge was      |
| struck by another vehicle and damaged severely.  The gauge was recovered and |
| taken to the shop where a survey indicated 8 millirem around the outside of  |
| the case.  A leak test is being conducted, results are not yet available.    |
| The company has contacted Troxler concerning the gauge.  More information    |
| will be available later.                                                     |
|                                                                              |
| * * * UPDATE AT 1316 EDT ON 9/24/02 FROM PAM BISHOP TO GERRY WAIG * * *      |
|                                                                              |
| The Oklahoma Dept. of Environmental Quality called to report that the        |
| damaged Troxler gauge, model #4640, serial #750143, is licensed to APAC      |
| Oklahoma Inc, P. O. Box 580670, 3605 North 129th East Ave, Tulsa, OK         |
| 74158-0670.  The source is a Cs-137,  7.1 millicurie source. The gauge has   |
| been disassembled and no external contamination was detected. Wipes and      |
| pictures of the damaged gauge have been sent to Troxler for evaluation. The  |
| damaged gauge is being held by the licensee in it's Shawnee, OK office. The  |
| APAC Radiation Safety Officer is Mr. John Ringwald (918) 438-2020.           |
|                                                                              |
| Notified R4DO (John Pellet) and NMSS (Doug Broaddus)                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39213       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  OR DEPT OF HEALTH RAD PROTECTION     |NOTIFICATION DATE: 09/24/2002|
|LICENSEE:  GEOPACIFIC TESTING                   |NOTIFICATION TIME: 11:43[EDT]|
|    CITY:                           REGION:  4  |EVENT DATE:        09/23/2002|
|  COUNTY:                            STATE:  OR |EVENT TIME:             [PDT]|
|LICENSE#:  ORE-90987             AGREEMENT:  Y  |LAST UPDATE DATE:  09/24/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN PELLET          R4      |
|                                                |DOUG BROADDUS        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  TERRY LINDSEY                |                             |
|  HQ OPS OFFICER:  GERRY WAIG                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|BLO1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MOISTURE DENSITY GAUGE LOST DURING TRANSPORT                                 |
|                                                                              |
| A Troxler gauge, model # 3440, serial # 19495 was lost while being           |
| transported from Beverton, OR to North Portland, OR. The gauge is an 8       |
| millicurie Cs-137, 40 millicurie Am-241 Be source and is licensed to         |
| GeoPacific Testing Inc, Tigard, OR 97224. The licensee discovered the lost   |
| gauge on 9/23/02 at approximately 1700 PDT and notified the State of Oregon  |
| on 9/23/02 at 1858 PDT. The gauge was lost north of Highway 26 between the   |
| intersection of Emily Lane and Northwest Bethany Blvd and Northwest          |
| Germantown Rd.  A search is being conducted to recover the lost gauge. A     |
| press release is planned. The Oregon State Police, Oregon Emergency Response |
| System, Washington County Sheriff, Beaverton Police and the Portland Police  |
| have been notified. The State of Oregon also intends to notify NRC Region    |
| 4.                                                                           |
|                                                                              |
| * * * UPDATE ON 9/24/02 AT 2138 EDT FROM TERRY LINDSEY TO GERRY WAIG * * *   |
|                                                                              |
| The Troxler moisture density gauge lost during transit was discovered by a   |
| passing volunteer fireman from Scapoose, OR. The fireman happened by the     |
| gauge, picked up the gauge and case, and secured it at the fire house. The   |
| gauge was found on 185th Ave., along the original route traveled when lost,  |
| approximately 15 minutes after it was lost.  The gauge was reported found    |
| after news of the missing gauge was aired today on local media. The gauge is |
| currently being stored by the Scapoose Fire Dept. and will be returned to    |
| GeoPacific Testing tomorrow.                                                 |
|                                                                              |
| Notified R4DO (John Pellet) and NMSS (John Greeves)                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39218       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK              REGION:  1  |NOTIFICATION DATE: 09/26/2002|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 14:10[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        09/26/2002|
+------------------------------------------------+EVENT TIME:        10:44[EDT]|
| NRC NOTIFIED BY:  PAGE                         |LAST UPDATE DATE:  09/26/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANIELLO DELLA GRECA  R1      |
|10 CFR SECTION:                                 |VERN HODGE           NRR     |
|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PART 21 REPORT FROM LICENSEE REGARDING MALFUNCTIONING OVERCURRENT SENSORS    |
|                                                                              |
| Two new EC-1 overcurrent sensors withdrawn from warehouse stock failed       |
| during bench testing in preparation for installation in the plant during the |
| upcoming refueling outage. The failure mode was premature tripping of the    |
| magnetic (instantaneous) element of the device, such that the associated     |
| circuit breaker would have tripped early and the corresponding loads would   |
| not have remained energized to perform their required safety function.       |
|                                                                              |
| The only application of these specific EC-l overcurrent sensors is in the    |
| circuit breaker used in cubicle 71-11510, which is the emergency bus feeder  |
| breaker providing 600 VAC power to Motor Control Center (MCC)- 151. (The     |
| circuit breaker contains a total of three of these devices, one per phase.)  |
| Electrical loads powered from this MCC include various safety systems such   |
| as the Standby Gas Treatment System (SBGT), Residual Heat Removal System     |
| (RHR) and High Pressure Coolant Injection System (HPCI). The loss of the MCC |
| could have resulted in the failure of SBGT to perform its safety function.   |
|                                                                              |
| The test information indicates that the circuit breaker would have           |
| prematurely tripped based on the starting current of the 'A' SBGT Exhaust    |
| Fan and thus the associated MCC would not have remained energized.  Assuming |
| a concurrent single failure of the 'B' SBGT subsystem, this could have       |
| resulted in the loss of both subsystems and the failure of SBGT to perform   |
| its safety function. Therefore, a substantial safety hazard existed in that  |
| the potential existed for a major deficiency/major degradation of essential  |
| safety-related equipment.                                                    |
|                                                                              |
| No other safety functions would have been lost.                              |
|                                                                              |
| Component and Supplier:                                                      |
| GE Model Type EC-1 Trip Device                                               |
| General Electric Nuclear                                                     |
| 225 Amp, 60 Cycle                                                            |
| M/C397                                                                       |
| Sensor Trip, Characteristic 1 B-2C                                           |
| 175 Curtner Ave.                                                             |
| GE P/N QEC10225ABCG10N00                                                     |
| San Jose, CA 95125                                                           |
| Serial Nos. 77386-3A and 77386-3B                                            |
|                                                                              |
| The defective components were placed in a "hold" status to prevent issuance  |
| in the plant.   A Corrective Action Request will be issued to General        |
| Electric for evaluation.                                                     |
|                                                                              |
| The NRC Resident Inspector was notified                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39219       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ARTIC PIPE INPSECTIONS               |NOTIFICATION DATE: 09/26/2002|
|LICENSEE:  ARTIC PIPE INSPECTIONS               |NOTIFICATION TIME: 17:06[EDT]|
|    CITY:  HOUSTON                  REGION:  4  |EVENT DATE:        09/26/2002|
|  COUNTY:                            STATE:  TX |EVENT TIME:        09:00[CDT]|
|LICENSE#:  50-17314-02           AGREEMENT:  Y  |LAST UPDATE DATE:  09/26/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN PELLET          R4      |
|                                                |JOHN GREEVES         NMSS    |
+------------------------------------------------+ANIELLO DELLA GRECA  R1      |
| NRC NOTIFIED BY:  JIM HILDEBRENDT              |RICHARD WESSMAN      IRO     |
|  HQ OPS OFFICER:  MIKE NORRIS                  |JOHN DAVIDSON        NSIR    |
+------------------------------------------------+DWIGHT CHAMBERLAND   R4      |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|BLO1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOST I-192 RADIOGRAPHY SOURCE DURING SHIPMENT                                |
|                                                                              |
| A 20.3 Curie Ir-192 radiography camera SN# 94 was being shipped from Kenin,  |
| AK to AEA Technologies in Burlington, MA by Federal Express.  The shipment   |
| arrived in Newark, NJ on 9/21/02 at 0257 and was scanned to leave on 9/24/02 |
| at 0022 EDT.  The Licensee reported that the camera has not arrived in MA,   |
| and that Federal Express could not account for the source's location.  The   |
| source was being shipped in it's shipping container and the Licensee         |
| believed that it had a combination lock on it.                               |
+------------------------------------------------------------------------------+