Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for September 24, 2002



                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/23/2002 - 09/24/2002

                              ** EVENT NUMBERS **

39201  39208  39209  39211  39212  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39201       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ALABAMA RADIATION CONTROL            |NOTIFICATION DATE: 09/19/2002|
|LICENSEE:  BUILDING AND EARTH SCIENCES          |NOTIFICATION TIME: 16:28[EDT]|
|    CITY:                           REGION:  2  |EVENT DATE:        09/18/2002|
|  COUNTY:                            STATE:  AL |EVENT TIME:             [CDT]|
|LICENSE#:  1266                  AGREEMENT:  Y  |LAST UPDATE DATE:  09/19/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |PAUL FREDRICKSON     R2      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DAVID WALTER                 |                             |
|  HQ OPS OFFICER:  MIKE RIPLEY                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MOISTURE DENSITY GAUGE STOLEN FROM THE BACK OF A PICKUP TRUCK                |
|                                                                              |
| "The writer received a call from [an employee] of Building and Earth         |
| Sciences at approximately 9:00 AM on September 19, 2002. The employee        |
| reported that a Troxler Model 3430 gauge (S/N 30199) had been stolen         |
| sometime during the night of September 18, 2002, from their truck working    |
| under reciprocity in Memphis, Tennessee.                                     |
|                                                                              |
| "The gauge had been left chained in the back of the truck overnight at [ . . |
| . . . ]. The chain had been cut, and the gauge taken. The licensee's         |
| employee had contacted both the State of Tennessee and had filed a report    |
| with the local police.                                                       |
|                                                                              |
| "The licensee is continuing their investigation, and considering additional  |
| methods to expedite recovery of the gauge."                                  |
|                                                                              |
| Contact the Headquarters Operations Officer for additional information.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   39208       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 09/23/2002|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 00:08[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        09/22/2002|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        16:42[CDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  09/23/2002|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |MARK RING            R3      |
|  DOCKET:  0707001                              |SUSAN FRANT          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  K.A. BEASLEY                 |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24 HOUR REPORT INVOLVING A VALID ACTUATION OF A "Q" SAFETY SYSTEM DUE TO A   |
| UF6 RELEASE                                                                  |
|                                                                              |
| "At 1642, on 9-22-02 the Plant Shift Superintendent (PSS) was notified of an |
| activation of a Q safety system in the C-333 process building. Operations    |
| personnel reported receiving a Process Gas Leak Detection (PGLD) alarm at    |
| Unit 5 Cell 9. The operators responded to the area according to their        |
| emergency response procedure and reported that a haze was visible in the     |
| area. Building personnel then reported that multiple PGLD alarms were        |
| received from other cells in the area. The location of the PGLD detectors    |
| that were alarming indicated that the UF6 release was located at the Unit 5  |
| cell bypass housing. All cells in Unit 5 were shutdown to reduce the process |
| pressure to below atmosphere. Following shutdown of the equipment, air       |
| sampling in multiple locations through out the building were obtained by the |
| plant emergency squad. After it was determined that all air samples showed   |
| no indication of an ongoing release, an all clear on the emergency was given |
| by the PSS. Trouble shooting by building personnel is in progress to         |
| determine the location of the system breach.                                 |
|                                                                              |
| "The PSS determined that this event is a 24 Hour Event Report due to the     |
| valid activation of a TSR required Q safety system.                          |
|                                                                              |
| "The NRC Resident inspector has been notified of this event."                |
|                                                                              |
| The duration of the release was estimated as approximately 10 minutes.       |
| Urine samples for four (4) maintenance personnel and ten (10) operators      |
| working in the area will be processed as a precautionary measure.            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39209       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OYSTER CREEK             REGION:  1  |NOTIFICATION DATE: 09/23/2002|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 09:14[EDT]|
|   RXTYPE: [1] GE-2                             |EVENT DATE:        09/23/2002|
+------------------------------------------------+EVENT TIME:        08:00[EDT]|
| NRC NOTIFIED BY:  GEORGE VOISHNIS              |LAST UPDATE DATE:  09/23/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JOHN KINNEMAN        R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO DISCHARGE PERMIT VIOLATION                       |
|                                                                              |
| The licensee notified the State of New Jersey due to a fish kill of greater  |
| than 100 fish killed, this is a violation of their discharge permit.  The    |
| licensee notified the NRC Resident Inspector.                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   39211       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 09/23/2002|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 21:50[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        09/23/2002|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        17:55[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  09/23/2002|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |KENNETH RIEMER       R3      |
|  DOCKET:  0707002                              |NADER MAMISH         IRO     |
+------------------------------------------------+DONALD COOL          NMSS    |
| NRC NOTIFIED BY:  GARY SALYERS                 |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 4-HOUR NRC BULLETIN 91-01 REPORT INVOLVING LOSS OF CRITICALITY CONTROLS      |
|                                                                              |
| "EVENT DESCRIPTION:  On 09/23/02, The Plant Shift Superintendent (PSS) was   |
| notified of a violation of NCSA-705_ 039 Control # 10 related to analysis of |
| solution transferred to the Oil and Grease Removal Unit (OGRU) in the X-705  |
| building. Specifically, the sample results utilized did meet control # 10 of |
| the Nuclear Critically Safety Analysis (NCSA) did not coincide with the      |
| material transferred. This represents the Loss of both controls for MASS     |
| which is a loss of double contingency controls applicable to the Fissile     |
| Material Operation (FMO). The material transferred was determined to be from |
| a Non-Fissile Operation.                                                     |
|                                                                              |
| "SAFETY SIGNIFICANCE OF EVENTS: The safety significance of this event is     |
| low. The container that was processed was from the motor cleaning operation  |
| in the X-720 Building which has determined to be a Non-Fissile Material      |
| Operation.                                                                   |
|                                                                              |
| "POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO[S] OF HOW           |
| CRITICALITY COULD OCCUR): Criticality could occur by processing material     |
| with a U235 mass greater than a critical mass into a unfavorable geometry    |
| container.                                                                   |
|                                                                              |
| "CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.):    |
| The controlled parameter in this operation is mass.                          |
|                                                                              |
| "ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS    |
| LIMIT AND % WORST CASE CRITICAL MASS):  The maximum amount of material in    |
| this event is 15 grams U235. The controlled enrichment is less than or equal |
| to 20 wt. % U235.  The form of the material is a water based solution that   |
| is contaminated with oil.                                                    |
|                                                                              |
| "NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION  |
| OF THE FAILURES OR DEFICIENCIES:  The NCS control that was lost is mass. The |
| NCSA requires that before a container processed two independent samples are  |
| obtained a batch calculation is performed with the data which is verified by |
| a second operator and then checked by a member of supervision.  Since the    |
| container which was processed did not match the container both checks were   |
| not correct.                                                                 |
|                                                                              |
| "CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEMS AND WHEN EACH WAS IMPLEMENTED: |
| The Oil and Grease Removal Unit was declared inoperable by the Plant Shift   |
| Superintendent on 09/23/2002."                                               |
|                                                                              |
| Operations will inform the DOE Site Representative and has informed the NRC  |
| Resident Inspector.                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39212       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE                REGION:  1  |NOTIFICATION DATE: 09/23/2002|
|    UNIT:  [] [] [3]                 STATE:  CT |NOTIFICATION TIME: 23:58[EDT]|
|   RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP           |EVENT DATE:        09/23/2002|
+------------------------------------------------+EVENT TIME:        23:35[EDT]|
| NRC NOTIFIED BY:  ROBERT MALONEY               |LAST UPDATE DATE:  09/24/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |PETE ESELGROTH       R1      |
|10 CFR SECTION:                                 |                             |
|AMED 50.72(b)(3)(xii)    OFFSITE MEDICAL        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          N       0        Refueling        |0        Refueling        |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTAMINATED WORKER TRANSPORTED OFFSITE FOR MEDICAL ASSISTANCE               |
|                                                                              |
| At 2335EDT on 9/23/02 a worker involved in decontamination activities inside |
| the Unit 3 containment was transported offsite to Lawrence and Memorial      |
| Hospital in New London, CT for medical assistance.  EMTs administered oxygen |
| to the worker who they believed was suffering from heat stress and           |
| hypertension.  A rad survey conducted onsite showed contamination levels of  |
| 1000 ccpm on his right thigh.  An HP technician and supervisor accompanied   |
| the worker to the hospital where he was decontaminated.                      |
|                                                                              |
| * * * UPDATE 0035EDT ON 9/24/02 FROM MALONEY TO S. SANDIN * * *              |
|                                                                              |
| The HP supervisor who accompanied the contaminated worker to the hospital    |
| notified the site that rad surveys completed at 0015EDT confirmed that the   |
| ambulance, the ambulance travel path and the hospital treatment room were    |
| free of contamination and free released.                                     |
|                                                                              |
| The licensee will inform state/local agencies and the NRC Resident           |
| Inspector.                                                                   |
+------------------------------------------------------------------------------+