The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for September 13, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
09/12/2002 - 09/13/2002
** EVENT NUMBERS **
39176 39177 39183 39184 39185 39186
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39176 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: LOUISIANA RADIATION PROTECTION DIV |NOTIFICATION DATE: 09/09/2002|
|LICENSEE: AMERICIAN RADIATION SERVICES, INC |NOTIFICATION TIME: 15:15[EDT]|
| CITY: HOUMA REGION: 4 |EVENT DATE: 09/05/2002|
| COUNTY: STATE: LA |EVENT TIME: [CDT]|
|LICENSE#: LA-7153-L01 AGREEMENT: Y |LAST UPDATE DATE: 09/09/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JACK WHITTEN R4 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: LA DEPT OF RAD PROTECTION | |
| HQ OPS OFFICER: GERRY WAIG | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TWO RADIOACTIVE SOURCES FOUND |
| |
| "American Radiation Services discovered two 1.5 curie sources of Cs-137 at |
| Shield Coat, Inc. while performing a survey for naturally occurring |
| radioactive material. The sources were identified as pipe wall thickness |
| caliper sources, The source with serial number 5171 was manufactured on |
| November 4,1982 by Ludlum, Inc. The source with serial number 3344 was |
| manufactured on January 25, 1983. Upon discovery the area was roped off and |
| the sources surveyed. Readings of 4.5 mr/hr and 5 mr/hr were found at one |
| foot from the sources. A smear of the source housings detected no alpha or |
| beta activity. The sources will be secured in a locked building until the |
| can be returned to Ludlum. The building will be posted with 'Caution: |
| Radiation Area', The last known possessor of the sources with the above |
| mentioned serial numbers was Randolph Clay in Houma, LA. An investigation is |
| ongoing at this time." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39177 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: LOUISIANA RADIATION PROTECTION DIV |NOTIFICATION DATE: 09/09/2002|
|LICENSEE: OCHSNER FOUNDATION |NOTIFICATION TIME: 15:15[EDT]|
| CITY: REGION: 4 |EVENT DATE: 05/05/2002|
| COUNTY: STATE: LA |EVENT TIME: [CDT]|
|LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 09/09/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JACK WHITTEN R4 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: SCOTT BLACKWELL | |
| HQ OPS OFFICER: RICH LAURA | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT OF POTENTIAL OVEREXPOSURE |
| |
| "Two employees received an excessive exposure at this facility. Landauer |
| read the badges again with the same results. One employee had a dose of 34.6 |
| rem and the other had a dose of 19.3 rem. A cause for the over exposure |
| could not be identified. On August 29 and 30, 2002, a representative of LDEQ |
| investigated the over exposure. After the investigation, it was concluded |
| that the two employees did not actually receive the dose." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 39183 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: BRANSCOME, INC. |NOTIFICATION DATE: 09/12/2002|
|LICENSEE: BRANSCOME, INC. |NOTIFICATION TIME: 07:07[EDT]|
| CITY: HAMPTON REGION: 2 |EVENT DATE: 09/12/2002|
| COUNTY: STATE: VA |EVENT TIME: 05:00[EDT]|
|LICENSE#: 45-23669-01 AGREEMENT: N |LAST UPDATE DATE: 09/12/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MIKE ERNSTES R2 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: DAVID TURNER | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NINF INFORMATION ONLY | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| POTENTIAL DAMAGE TO TROXLER GAUGE DURING FIRE |
| |
| A structure fire at the Branscome, Inc. facility located at 1922 W. Pembroke |
| Ave., Hampton, VA 23166 may have damaged their Troxler Model 4640-B gauge, |
| S/N 855. This gauge which is used to measure asphalt thickness contains a 9 |
| millicurie Cs-137 source. The licensee has visually confirmed that the case |
| is melted, however, no rad surveys have been performed in that the Hampton |
| FD is restricting access to the facility. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39184 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VERMONT YANKEE REGION: 1 |NOTIFICATION DATE: 09/12/2002|
| UNIT: [1] [] [] STATE: VT |NOTIFICATION TIME: 09:46[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 09/12/2002|
+------------------------------------------------+EVENT TIME: 08:05[EDT]|
| NRC NOTIFIED BY: MAY |LAST UPDATE DATE: 09/12/2002|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |DAVID LEW R1 |
|10 CFR SECTION: | |
|ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 99.6 Power Operation |99.6 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| THE PLANT LOST EMERGENCY THE NOTIFICATION SYSTEM TO THE STATE OF VERMONT |
| |
| The plant lost the primary and alternate Nuclear Alert System telephone |
| links to the State of Vermont at 0740. They verified communication with |
| alternate state police barracks. The system was returned to service at |
| 0920. |
| |
| The NRC Resident Inspector was notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital |Event Number: 39185 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: FAIRMOUNT GENERAL HOSPITAL |NOTIFICATION DATE: 09/12/2002|
|LICENSEE: FAIRMOUNT GENERAL HOSPITAL |NOTIFICATION TIME: 17:39[EDT]|
| CITY: FAIRMOUNT REGION: 2 |EVENT DATE: 09/12/2002|
| COUNTY: STATE: WV |EVENT TIME: 12:30[EDT]|
|LICENSE#: 47-17929-01 AGREEMENT: N |LAST UPDATE DATE: 09/12/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MIKE ERNSTES R2 |
| |JANET SCHLUETER NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: SANDY WELLS | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NONR OTHER UNSPEC REQMNT | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| RADIOACTIVE MEDICAL WASTE PACKAGE |
| |
| A patients radioactive waste was inadvertently sent from Fairmount General |
| Hospital on 08/28/02 to Stericycle, Medical Waste Facility located in |
| Warren, Ohio. When the package arrived at the Stericycle Medical Waste |
| Facility it triggered their radiation monitor. On 09/06/02 Stericycle |
| informed Fairmount General Hospital that they had received a radioactive |
| waste package from them and that they were not licensed to hold radioactive |
| materials at their facility. Fairmount General Hospital picked the package |
| up today from Stericycle and it is has been placed in a radioactive decay |
| room at the Hospital. The source of the radioactivity at this time is |
| unknown. The package has only internal fixed contamination and the internal |
| radioactive level of the package is 0.2 millirems per hour. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39186 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PILGRIM REGION: 1 |NOTIFICATION DATE: 09/12/2002|
| UNIT: [1] [] [] STATE: MA |NOTIFICATION TIME: 20:18[EDT]|
| RXTYPE: [1] GE-3 |EVENT DATE: 09/12/2002|
+------------------------------------------------+EVENT TIME: 18:41[EDT]|
| NRC NOTIFIED BY: K. GRACIA |LAST UPDATE DATE: 09/12/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |DAVID LEW R1 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 50 Power Operation |74 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| BOTH TRAINS OF CONTROL ROOM HIGH EFFICIENCY AIR FILTRATION WERE INOPERABLE |
| AT THE SAME TIME. |
| |
| "PNPS I&C Design Engineering determined that modifications of CRHEAF-B |
| humidistat after removal of temporary modification bypassing the switch |
| caused the switch to not perform per design. This would inop the system if |
| high humidity was present because the wiring configuration would turn off |
| the heater if high humidity was present. The system would not perform its |
| design function for the mission length required due to this. Due to this |
| both trains of CRHEAF have been determined to have been inop at the same |
| time while the CRHEAF-A was tagged out for planned maintenance. CRHEAF-A |
| has been returned to operable status while repairs to CRHEAF-B are |
| in-progress. Both trains were inoperable for approximately 4 and 1/2 hours. |
| An ACTIVE LCO for 36 hours was entered." |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021