Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for July 30, 2002

      
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/29/2002 - 07/30/2002

                              ** EVENT NUMBERS **

39090  39091  
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39090       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  MISSISSIPPI DIV OF RAD HEALTH        |NOTIFICATION DATE: 07/25/2002|
|LICENSEE:  BURNS, COOLEY AND DENNIS, INC        |NOTIFICATION TIME: 11:30[EDT]|
|    CITY:  JACKSON                  REGION:  2  |EVENT DATE:        07/24/2002|
|  COUNTY:                            STATE:  MS |EVENT TIME:             [CDT]|
|LICENSE#:  MS61901               AGREEMENT:  Y  |LAST UPDATE DATE:  07/25/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MARK LESSER          R2      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JOSH GRISHAM                 |                             |
|  HQ OPS OFFICER:  MIKE NORRIS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE                      |
|                                                                              |
| A Troxler gauge model 3440, serial number 31621, was stolen out of the bed   |
| of a truck in front of a private residence.  The vehicle was parked at 2300  |
| on 7/24/02 and the gauge was found missing at 0700 on 7/25/02.   The gauge   |
| contains 8 millicuries of Cs-137 and 40 millicuries of Am-241:Be.  Local law |
| enforcement has notified and a press release is planned for the local        |
| newspaper.                                                                   |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39091       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FLORIDA BUREAU OF RADIATION CONTROL  |NOTIFICATION DATE:
07/25/2002|
|LICENSEE:  ATLANTIC DRILLING SUPPLY             |NOTIFICATION TIME: 12:00[EDT]|
|    CITY:  ORLANDO                  REGION:  2  |EVENT DATE:        07/03/2002|
|  COUNTY:                            STATE:  FL |EVENT TIME:             [EDT]|
|LICENSE#:  2830-1                AGREEMENT:  Y  |LAST UPDATE DATE:  07/25/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MARK LESSER          R2      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+RICHARD WOODRUFF     R2      |
| NRC NOTIFIED BY:  CHARLIE ADAMS                |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - MISSING SOIL DENSITY GAUGE                          |
|                                                                              |
| Atlantic Drilling Supply shipped a CPN Model NC3 moisture density gauge      |
| (serial number M310800431, containing 10 millicuries Cs-137 and 50           |
| millicuries Am-241:Be) to CPN International in Martinez, CA for calibration. |
| The gauge was shipped via Conway Southern Express.  The shipment has been    |
| traced to Jacksonville where there is paperwork indicating shipment on to    |
| Atlanta.  There is no paperwork or other indication of the shipment arriving |
| in Atlanta.  There is an investigation ongoing to determine the actual       |
| location of the shipment.                                                    |
+------------------------------------------------------------------------------+
.

                