Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for July 29, 2002

      
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/26/2002 - 07/29/2002

                              ** EVENT NUMBERS **

39084  39093  39095  39098  39099  39100  
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39084       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NE DIV OF RADIOACTIVE MATERIALS      |NOTIFICATION DATE: 07/23/2002|
|LICENSEE:  GEOTECHNICAL SERVICES, INC.          |NOTIFICATION TIME: 16:52[EDT]|
|    CITY:  OMAHA                    REGION:  4  |EVENT DATE:        07/23/2002|
|  COUNTY:                            STATE:  NE |EVENT TIME:        12:39[CDT]|
|LICENSE#:  0138-01               AGREEMENT:  Y  |LAST UPDATE DATE:  07/23/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JONES           R4      |
|                                                |ERIC LEEDS           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  SUE SEMERENA                 |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING THE DISCOVERY OF A CPN MOISTURE
DENSITY     |
| GAUGE BY A THIEL GEOTECH CLIENT IN OMAHA, NEBRASKA, AND THE SUBSEQUENT  
    |
| REPORT OF THE LOSS OF THE SAME GAUGE BY GEOTECHNICAL SERVICES, INC.         
|
|                                                                              |
| At approximately 1100 CDT on 07/23/02, an engineering company (Thiel         |
| Geotech) notified the Nebraska Division of Radioactive Materials that one of |
| their clients had found a CPN moisture density gauge.  The gauge was         |
| discovered in a pad-locked transport container at a construction site        |
| (approximately 180th and Harrison) in Omaha, Nebraska.  Thiel Geotech is     |
| licensed to use/hold similar gauges, and representatives of Thiel Geotech    |
| transported the gauge to their office in order to secure it.                 |
|                                                                              |
| The State reported that the gauge (model CPN-131, serial number MD00105439)  |
| contained a maximum of 50 millicuries of americium-241/beryllium and a       |
| maximum of 10 millicuries of cesium-137.  At the request of the State, Thiel |
| Geotech broke through the padlock to check the gauge and to perform surveys. |
| There was no observable damage, and the survey results were normal.  The     |
| State was able to identify the owner of the gauge fairly soon via an         |
| ownership label and the serial number.                                       |
|                                                                              |
| At approximately 1239 CDT on 07/23/02, Geotechnical Services, Inc., notified |
| the Nebraska Division of Radioactive Materials of the loss of the same       |
| gauge.  Geotechnical Services, Inc., also notified local law enforcement.    |
|                                                                              |
| The Nebraska Division of Radioactive Materials has had several conversations |
| with both companies and has also been in contact with local law enforcement. |
| The State requested Thiel Geotech to hold the gauge pending the State's      |
| investigation, which is currently planned for tomorrow.                      |
|                                                                              |
| (Call the NRC operations officer for a Nebraska Division of Radioactive      |
| Materials contact telephone number.)                                         |
+------------------------------------------------------------------------------+
.
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39093       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MCGUIRE                  REGION:  2  |NOTIFICATION DATE: 07/25/2002|
|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 19:06[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        07/25/2002|
+------------------------------------------------+EVENT TIME:        17:05[EDT]|
| NRC NOTIFIED BY:  VERIDA BELLAMY               |LAST UPDATE DATE:  07/26/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |MARK LESSER          R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH TRAINS OF CONTROL ROOM AREA CHILL WATER INOPERABLE                      |
|                                                                              |
| The train 'A' control room area chill water was declared inoperable at 1350  |
| EDT due to a refrigerant leak.  Subsequently the train 'B' control room area |
| chill water tripped and at 1705 EDT technical specification 3.0.3 was        |
| entered due to both trains being inoperable.  At 1747 EDT the train 'A' was  |
| declared operable and the technical specification 3.0.3 was exited.  The     |
| report is made due to the 42 minutes both trains were inoperable which could |
| have prevented the performance of a safety function.  Troubleshooting        |
| continues on train 'B'.                                                      |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| * * * RETRACTED AT 1305 EDT ON 7/26/02 BY JIM DEAN TO FANGIE JONES * * *     |
|                                                                              |
| The licensee is retracting the event based on further determination that the |
| 'A' train of the control room area chill water system remained operable and  |
| capable of performing its safety related function in the presence of the     |
| refrigerant leak.                                                            |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The R2DO (Mark Lesser)    |
| was notified.                                                                |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   39095       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NORWALK HOSPITAL                     |NOTIFICATION DATE: 07/26/2002|
|LICENSEE:  NORWALK HOSPITAL                     |NOTIFICATION TIME: 10:00[EDT]|
|    CITY:  NORWALK                  REGION:  1  |EVENT DATE:        07/23/2002|
|  COUNTY:                            STATE:  CT |EVENT TIME:             [EDT]|
|LICENSE#:  06-06941-01           AGREEMENT:  N  |LAST UPDATE DATE:  07/26/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |RICHARD CONTE        R1      |
|                                                |MELVYN LEACH         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MALCOLM POWELL               |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|BLO2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| I-125 SEED UNACCOUNTED FOR FOLLOWING IMPLANTATION                            |
|                                                                              |
| On 7/23/02 a male patient underwent surgery for implantation of Iodine-125   |
| seeds as part of the treatment plan for prostate cancer.  Following the      |
| surgery, the technician discovered that only 7 instead of 8 of the original  |
| 110 seeds delivered to the OR [Operating Room] were remaining.  A survey of  |
| the area was unable to locate the missing seed [338 millicuries].  The RSO   |
| believes that either the missing seed was inadvertently washed down the OR   |
| sink drain during cleanup or that 103 instead of 102 seeds prescribed were   |
| implanted.  The licensee will submit a written report within 30 days.        |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39098       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 07/27/2002|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 01:04[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        07/26/2002|
+------------------------------------------------+EVENT TIME:        21:24[EDT]|
| NRC NOTIFIED BY:  DAVID T. WALSH               |LAST UPDATE DATE:  07/27/2002|
|  HQ OPS OFFICER:  MIKE NORRIS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |MELVYN LEACH         NMSS    |
|QDEF 72.75(b)(2)         SPENT FUELCASK DEFECT  |MICHAEL TOKAR        SFPO    |
|QRED 72.75(b)(3)         SPENT FUEL CASK EFFECTI|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DRY FUEL STORAGE CASK FILLED WITH WRONG GAS                                  |
|                                                                              |
| "At 09:24 p.m. on 7/26/02, the Shift Manager was notified by the Refueling   |
| Floor Manager that a Dry Fuel Storage cask had been accidentally filled with |
| an argon/helium gas mix in lieu of 100% helium gas as required by the        |
| certificate of compliance for Susquehanna's Dry Fuel Cask Storage program.   |
| The affected cask was in the process of being sealed and prepared for        |
| shipment from the Refueling Floor to the Horizontal Storage Module located   |
| on site. Site Engineering and the vendor have been contacted to provide      |
| guidance on the affect of the argon gas on the Storage System. Temperature   |
| monitoring is in progress to detect any changes in the loaded canister until |
| a final determination can be made. Because of the reduction in the thermal   |
| conductivity of the argon/helium mixture, this defect is believed to         |
| represent a potential significant reduction in the effectiveness of the      |
| spent fuel confinement system and is reportable under 10 CFR 72.75(b)(2) and |
| 10 CFR 72.75(b)(3)."                                                         |
|                                                                              |
| The NRC Resident Inspector has been notified.                                |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39099       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 07/27/2002|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 13:36[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        07/27/2002|
+------------------------------------------------+EVENT TIME:        01:10[EDT]|
| NRC NOTIFIED BY:  JIM TURKETT                  |LAST UPDATE DATE:  07/27/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |MARK LESSER          R2      |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INFORMATION CALL THAT INVOLVES LOCAL AUTHORITIES AND POSSIBLE MEDIA         
|
| ATTENTION                                                                    |
|                                                                              |
| The licensee's security personnel discovered a stub end of a hand rolled     |
| cigarette of questionable material in the room above diesel generator 'A.'   |
| It appeared old and had no odor.  Fairfield County Sheriff's Department was  |
| contacted and they dispatched a unit.  They potentially identified the       |
| contents as marijuana and took custody of the cigarette.  They will submit   |
| it to the South Carolina State Law Enforcement Division for analysis.  The   |
| analysis will take about a week or more and followup notification will be    |
| made if needed.  This notification was made due to Fairfield County          |
| involvement and possible media coverage.  There is no impact on plant        |
| operation.                                                                   |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39100       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 07/27/2002|
|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 15:47[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        07/27/2002|
+------------------------------------------------+EVENT TIME:        12:27[CDT]|
| NRC NOTIFIED BY:  JOE BENNETT                  |LAST UPDATE DATE:  07/27/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |MARK LESSER          R2      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR SCRAM ON MAIN GENERATOR LOAD REJECT                        |
|                                                                              |
| "On 7/27/02 at 1227 CDT, Browns Ferry Unit 2 scrammed due to a Main          |
| Generator load reject signal, when the Main Generator breaker opened.  The   |
| breaker trip was caused by a Generator Neutral Overvoltage relay trip.  The  |
| cause of the Generator Neutral Overvoltage is under investigation.  All      |
| systems responded as required to the scram signal, no ECCS initiations       |
| occurred as a result of the scram signal.  As expected, Main Steam Relief    |
| Valves (MSRVs) opened due to the high reactor pressure as a result of the    |
| Main Turbine/Generator trip."                                                |
|                                                                              |
| The licensee is investigating the cause of the trip and will remain in Hot   |
| Shutdown until everything is known prior to plant startup.                   |
|                                                                              |
| The licensee informed the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+
.

                