Event Notification Report for July 18, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 07/17/2002 - 07/18/2002 ** EVENT NUMBERS ** 39054 39055 . +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39054 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: NE DIV OF RADIOACTIVE MATERIALS |NOTIFICATION DATE: 07/12/2002| |LICENSEE: SYNCOR PHARMACY |NOTIFICATION TIME: 11:22[EDT]| | CITY: OMAHA REGION: 4 |EVENT DATE: 07/05/2002| | COUNTY: STATE: NE |EVENT TIME: 10:00[CDT]| |LICENSE#: 01-65-01 AGREEMENT: Y |LAST UPDATE DATE: 07/12/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |THOMAS ANDREWS RDO | | |FRED BROWN NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: MILLER | | | HQ OPS OFFICER: CHAUNCEY GOULD | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SYNCOR PHARMACY REPORTED THAT A DELIVERY VEHICLE CONTAINING TECHNETIUM 99 | | WAS STOLEN | | | | A courier vehicle carrying a Yellow II labeled package containing 125 | | millicuries of Technetium 99m was stolen in Omaha, NE on 7/5/02. The driver | | had stopped briefly to perform a personnel errand while he was on a delivery | | to Norfolk, NE. As of this date, neither the vehicle nor the nuclear | | pharmaceutical have been located. The local police have been notified and | | there has been some media interest. | +------------------------------------------------------------------------------+ . +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39055 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: WA DIVISION OF RADIATION PROTECTION |NOTIFICATION DATE: 07/12/2002| |LICENSEE: SWEDISH MEDICAL CENTER |NOTIFICATION TIME: 17:12[EDT]| | CITY: SEATTLE REGION: 4 |EVENT DATE: 07/12/2002| | COUNTY: STATE: WA |EVENT TIME: [PDT]| |LICENSE#: WN-m008-1 AGREEMENT: Y |LAST UPDATE DATE: 07/12/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |GAIL GOOD R4 | | |M. WAYNE HODGES NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: TERRY C. FRAZEE | | | HQ OPS OFFICER: LEIGH TROCINE | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT REGARDING INCORRECT ENTRY OF CATHETER POSITION/LENGTH | | INTO THE TREATMENT PLANNING SYSTEM RESULTING IN MISMATCHED HDR DWELL TIME | | AND CATHETER AT SWEDISH MEDICAL CENTER IN SEATTLE, WASHINGTON | | | | The following text is a portion of an e-mail received from the WA Department | | of Health, Division of Radiation Protection: | | | | "This is notification of an event in Washington state as reported to the WA | | Department of Health, Division of Radiation Protection." | | | | "STATUS: new" | | | | "Licensee: Swedish Medical Center" | | | | "City and state: Seattle, WA" | | | | "License number: WN-m008-1" | | | | "Type of license: medical broad scope" | | | | "Date of event: July 11, 2002" | | | | "Location of Event: Seattle, WA" | | | | "ABSTRACT: (where, when, how, why; cause, contributing factors, corrective | | actions, consequences, DOH onsite investigation; media attention) Incorrect | | entry of catheter position/length into the treatment planning system | | resulted in mismatched HDR dwell time and catheter. The error was noted | | after the second of four planned treatments. Estimates of the actual doses | | already delivered indicated from 17% to 25% underexposure to certain target | | volumes and 25% to 50% additional exposure to adjacent normal tissue. Each | | of the four treatments was intended to deliver 600 centigray through three | | catheters with varying dwell times. In effect, two catheters were | | 'reversed' in the planning system and a 'long' dwell was used in a 'short' | | catheter, and vice versa. At the end of the second treatment, a significant | | volume of the target tissue received only 900 to 1000 centigray instead of | | the intended 1200 centigray. The licensee determined that the overall | | therapy was "salvable" and by modifying subsequent treatments would be able | | to correct the dose to the target tissue and at the same time minimize any | | additional dose to the adjacent normal tissue. No adverse effects are | | anticipated. The licensee generates a customized plan and treatment | | verification flow chart under its quality assurance program for each | | patient. The licensee has determined that the sign-off for 'number of | | catheters' needs to be modified to 'number and labeling of catheters' as the | | appropriate corrective action." | | | | "What is the notification or reporting criteria involved? WAC 246-240-050 | | Notifications, records, and reports of therapy misadministrations." | | | | "Activity and Isotope(s) involved: 3.3 Ci Ir-192" | | | | "Device (HDR, etc.) Mfg., Model; computer program: Nucletron | | MicroSelectron-HDR 'Classic' " | | | | "Exposure (intended/actual); consequences: 1200 centigray intended/900 | | centigray actual" | | | | "Was patient or responsible relative notified? (will be)" | | | | "Was written report provided? (not yet)" | | | | "Was referring physician notified? YES" | | | | "Consultant used? NO" | | | | (Contact the NRC operations officer for State contact information.) | +------------------------------------------------------------------------------+ .
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021